parameter:
Number of beats (number of frequencies)
automatic
The beats automatically selected by the instrument are:
12000, 14400, 18000, 19800, 21600, 25200, 28800, 36000, 43200.
Manual selection can select the number of beats that the instrument does not automatically recognize and the number of beats that are rare.
The manually selected beats are:
3600,6000,7200,7380,7440,7800,9000,9100,10800,11880,12000,12342,12480,12600,13320,13440,13500,14000,14040,14160,14200,14240,1484,14240,1 14760, 14850, 118, 16200, 16320, 16800, 17196, 17258, 17280, 11786, 17897, 18000, 18049, 18514, 11332, 19440, 19800, 20160, 20222, 20944, 21000, 21031, 21306, 21600, 25200, 28800, 32400, 36000, 43200.
rising angle:
The lift angle of most common movements is 52°, so the instrument is factory-set with a lift angle value of 52°. This value is needed when calculating the swing, and the lift angle can be set between 30° and 70°.
The measurement periods are:
2s, 4s, 8s, 12s, 20s, 30s, 60s are used to calculate the average of the test results.
Measurement range the daily difference, swing, polarization, and lines of the mechanical watch show the time of the watch.
Number of frequencies: beats for common watches can be automatically selected, or less common beats can be selected manually.
Daily difference measurement: ±999 seconds/day in digital display, 1 second/day in the measurement range.
Swing measurement: digital display, the division rate is 1°, the measurement range is 100°-360° (the rising angle value will affect the swing, the range is 30°-70°. Under normal circumstances, the swing range of the watch should not exceed 330°)
Measurement average: 2s, 4s, 8s, 12s, 20s, 30s, 60s.
Polarization measurement: The numerical unit is millisecond; the resolution is 0.1 millisecond, and the measurement range is 0.0-9.9 seconds.
Rise angle: The measurement range of the rise angle is 30°—70°, and the factory setting is 52°.
Supply voltage: single-phase AC 100V-240V±10% two-wire.
Measurement orientation: 1-6 orientations.