Electrical & Outputs
- Nominal Operating Voltage: 24 V DC.
- Channel Output Capacity: Typically handles 500 mA current capacity per output branch.
- Signal Type: Digital Sourcing (PNP switching style logic to drive standard industrial loads like solenoids, contactors, and indicators).
Fieldbus Interface
- Protocol Network: INTERBUS-S fieldbus standard.
- Local Bus Speed: 500 kbps transmission speed across the ring topology.
- System Diagnostics: Features an internal module identification map number code (Module Ident: 141) ensuring the host PLC master automatically indexes and configures the hardware node on startup.
Safety & Mechanical Design
- Device Safety: Features integrated internal overcurrent fuses to shield the logic bus components from shorted field-side connections.
- Mounting Integration: Formed on a heavy-duty industrial housing framework intended to lock straight down onto a standard symmetrical 35mm DIN rail layout.