

Product Description
Weishi1900!!!!!!!!
Specifications:
Main material: ABS
Supply Voltage: AC 100V-240V 50/60Hz
Measuring possibilities: rate deviation, amplitude, be-at error of mechanical watches and diagram recording of the be-at noise.
Rate deviation measurement:
Measuring ranges: ±999s/d or ±99.9s/d
Resolution: 1.0s/d or 0.1s/d
Amplitude measurement:
Measuring ranges: 100°~360°
Resolution: 1°
Measuring of the be-at error:
Measuring ranges: 0.0~9.9 ms
Resolution: 0.1 milliseconds
Lift angle:
Measuring ranges: 30°~70°
Default value: 52°
Measure positions: 1-6 positions
Line length: 480 points
Measuring times periods: 2/4/6/8/12/20/30/60 seconds
Language: Chinese, English, Japanese
Display: color LCD graphic monitor, 480*272 pixels
Working environment: 10℃~40℃
Relative humidity: 0~80% RH
Item size: 185 * 120 * 40mm / 7.3 * 4.7 * 1.6in
Item weight: 337g / 11.9ounce
Package size: 230 * 210 * 195mm / 9.1 * 8.3 * 1.6in
Package weight: 1379g / 3.0lb
Automatic:
The following beat numbers are selected by automatic selection mode:12000、14400、18000、19800、21600、25200、28800、36000、43200。
(If the tested beat is not in automatically selection, the instrument will display the closest beat number, but the test result is not correct. At this time, use the manual mode to select the relative beat.)
Manual selection:
It can selected out the beat number that Automatic select can not identify and rare beat number.
The following beat are selected by Manual selection mode:
3600、6000、7200、7380、7440、7800、9000、9100、10800、11880、12000、12342、12480、12600、13320、13440、13500、14000、14040、14160、14200、14280、14400、14520、14580、14760、14850、15000、15360、15600、16200、16320、16800、17196、17258、17280、17786、17897、18000、18049、18514、19332、19440、19800、20160、20222、20944、21000、21031、21306、21600、25200、28800、32400、36000、43200.
Feature:
The frequency diagram of the watch can be displayed on the LCD screen.
According to different watches, the instrument will automatically adjust the optimal signal level during the test.
The instrument will automatically calculate the rate deviation, amplitude, be-at error, and display them by the data in real time; select "±99.9s/d" at item rate ranges for result display, which can make the accuracy of rate deviation up to 0.1s/d.
For the conventional be-at, the instrument can automatically respond; for the special be-at, can manually select.
The sampling period can be selected by 2 seconds, 4 seconds, 6 seconds, 8 seconds, 12 seconds, 20 seconds, 30 seconds, 60 seconds, and the average value of corresponding period will be regarded as the precise value of the watch.
Six kinds of testing positions can be adjusted, and the simulation sound can be played in the speaker or mute.
Package Included :
1 * Timegrapher
1 * Timegrapher Sensor
1 * Adapter (US/UK/EU/AU)
1 * User Manual
Weishi 1000!!!!!!!!
Important Notes:
If you need further product usage instructions, please feel free to consult our customer service team for more information.
Weishi No.1000 Timing Timegrapher Accuracy Mechanical Watch Tester Calibrator
Features:
Warranty card provided.
This mechanical watch tester is a highly accurate test instrument that allows watch manufacturers and watchrepair technicians to easily test mechanical watches.
It adopts PC flame-retardant housing with high flame-retardant properties, stability, and wear resistance, with long durability.
The 98*34mm LCD screen has a resolution of 192*64 pixels, and the data lines are clearly visible. The entire frequency diagram of the watch can be displayed on the LCD screen.
During testing, the instrument automatically adjusts the optimal signal strength for different watches.
It can automatically calculate the values of deviation, amplitude, and beat error, and display the data in real-time.
The instrument can automatically detect watches with regular beat and can manually select watches with special beat.
2s, 4s, 6s, 8s, 10s, 20s, 30s, 60s test periods can be selected and the average value of the watch time of the selected period can be calculated.
Adjustable for 6 test orientations, with or without analogue sound can be set during the test.
Specifications:
Plug: US-plug,
Main material: metal
Color: black
Measuring possibilities: rate deviation, amplitude, be-at error
Rate deviation measurement: the ranges of deviation is ±999 sec/day, accuracy is 1.0 sec/day
Amplitude measurement: numerical display in degrees, resolution is 1°, measuring ranges is 100° to 360°
Measuring for the be-at error (frequency error): numerical display in milliseconds. Resolution is 0.1 milliseconds; the measuring ranges is 0-9.9 ms
Measuring position: 1 to 6 positions
Sampling periods: 2/4/6/8/12/20/30/60s
Lift angle: 30° to 70°, default is 52°
Line length: 196 points
Language: Chinese, English, Japanese
Display dimensions: 98 * 34mm / 3.9 * 1.3in
Item size: 172 * 114 * 40mm / 6.8 * 4.5 * 1.6in
Item weight: 1400g / 3.1lb
Package size: 200 * 150 * 80mm / 7.9 * 5.9 * 3.1in
Package weight: 1483g / 3.3lb
Packing List:
1 * Timegrapher(US Plug)
1 * Microphone
1 * Power Cable
1 * User Manual
Note:
1. Please allow minor deviation due to manual measurement.
2. Due to the difference between different monitors, the picture may not reflect the actual color of the item.
3. Communication is the best way to solve the problem. If you have any problems after purchasing, please contact us in time, before opening return or case.