| Frequency |
| Range |
Diplexer |
Upstream |
Downstream |
| ONX-630 - Automatically Switching Diplexer |
42/85 |
4 - 42 MHz and 4 - 85 MHz |
54 - 1,004 MHz and 108 - 1,218 MHz |
| 65/204 |
4 - 65 MHz and 4 - 204 MHz |
83 - 1,218 MHz and 258 MHz - 1,218 MHz |
| Accuracy |
±10 ppm typical @25°C |
| Downstream Analysis — Port 1 |
| AutoChannel plan builder |
Auto detection of channel parameters (analog/digital, symbols, QAM) |
| Max input power |
60 dBmV total integrated power |
| Operation on powered tap |
Operate with up to 90 V AC/DC on input port |
| Power detection / notification |
Notify of AC/DC power presence on port 2 above 2 Volts |
| Return loss |
>9 dB |
| Upstream Analysis - Port 2 |
| Ingress spectrum scan |
0.5 – 204 MHz |
| Sensitivity |
−45 dBmV |
| RBW |
300 kHz |
| Min detectable level upstream |
−55 dBmV |
| Dynamic range |
ONX-630 – 60dB |
| Max total integrated power |
55 dBmV, 4 – 10 MHz; 60 dBmV, 10 to 204 MHz |
| Accuracy |
±2 dB typical at 25°C |
| Sampling rate |
Hyper SpectrumTM FFT gapless technology - no missed samples, spans 0.5 -110 MHz, 110 to 160 MHz, and 160 to 204 MHz |
| Return loss |
>9.5 dB |
| Operation on powered tap |
Operate with up to 90 V AC/DC on input port |
| Power detection / notification |
Notify of AC/DC power presence on port 2 above 2 Volts |
| Upstream Signal Generator |
| Number of signals generated simultaneously |
From 1 to 8 |
| Signal types |
signals either all CW or all modulated |
| Modulation supported |
QPSK, 16 QAM, and 64 QAM |
| Symbol rates supported |
5.12, 2.56, 1.28, 0.64, 0.32, and 0.16 Msym/s |
| Analog Channel Measurement |
| Video and audio levels (dual) |
| Standards |
NTSC , PAL, SECAM |
| Min detectable signal |
−50 dBmV (single channel) |
| Level accuracy |
±1.5 dB from −20 dBmV to +50 dBmV typical at 25°C; ±2.0 dB, −10°C to +50°C |
| RBW |
300 kHz |
| Carrier to Noise |
| Channel types |
NTSC , PAL, SECAM, non-scrambled |
| Range |
30 to 51 dB (NTSC, 4 MHz measurement bandwidth) |
| Required input level |
0 to +40 dBmV with 77 analog channels present, maximum ±15 dB tilt 50 to 1,000 MHz |
| Accuracy |
±2.0 dB within specified measurement range ≤ 600 MHz |
| Downstream Digital Channel Analysis |
| Calibrated power levels |
-20 dBmV to +50 dBmV |
| Level accuracy |
±1.5 dB from -20 dBmV to +50 dBmV typical at 25°C; ±2.0 dB, -10°C to +50°C |
| Modulation(s) |
64, 128, and 256 QAM, OFDM |
Annex A: 5.057 to 6.952 MSPS Annex B: 5.057 for 64 QAM and 5.361 MSPS for 256 QAM Annex C: 5.274 MSPS for 64 QAM and 5.361 MSPS for 256 QAM |
| Regional demods |
DVB-C |
Full span MER Ingress under carrier — full span ingress noise trace Group delay and in-channel frequency response (ICFR) Digital quality index (DQI) over time Errored/severely errored seconds Level, measured symbol rate, carrier frequency, modulation, interleaver depth |
| Hum Specification |
| Hum frequency range |
25 Hz to 1000 Hz |
| Minimum MER |
33 dB |
| Accuracy up to 5% hum |
+/- 0.8% |
| From 5% to 10% |
+/- 1.0% |
| OFDM Signal Performance Metrics |
| OFDM Channels |
24 - 192 MHz wide - up to 3 active OFDM channels |
| Level - max, min, average, standard deviation |
relative to a 6 MHz carrier per CableLabs |
| MER - max, min, average, standard deviation, percentile |
12 to 50 dB |
| MER channel band graph |
max, min, avg across entire OFDM carrier |
| Noise |
max |
| Echo |
dBc |
| ICFR |
in-carrier frequency response (dB) |
| Spectrum/IUC |
spectrum display, including carrier and ingress under carrier |
| OFDM Profile Analysis |
| Profiles A, B, C, D, NCP, and PLC (more profiles as implemented) Lock status, codeword errors (corrected and uncorrected) |
| DOCSIS Testing |
Supports DOCSIS 3.1 bonding up to 32 SC-QAM + 2 OFDM downstream channels, 8 SC-QAM + 2 OFDMA upstream channels Compliant with CableLabs® specifications for DOCSIS 3.1 Compliant with CableLabs® specifications for DOCSIS 3.0 (32x8 bonding) |
| Displayed DOCSIS Results |
| Top level |
Number of bonded channels, min receive level, max BER (pre-FEC), min and max MER, max transmit level, max ICFR (in-channel frequency response) |
| Details |
Downstream SC-QAM (over time charts: level, MER, BER, DQI), Upstream (charts: transmit over time, upstream ICFR, upstream EQ taps |
| Service tests |
Registration, Throughput, Ping/ Traceroute, Packet Quality; cable modem pass-through |
| OFDM |
OFDM selected in scan, number of subcarriers, PLC lock status, frequency, level, and MER, CWE (corr, uncorr); OFDM channel(s) - Level variation (max, min, avg), MER variation (max, min, avg), ICFR, profile analysis (locked, CWE corr, CWE uncorr) |
| Downstream |
| Frequency range |
54/85/108/258 to 1,000/1,218 MHz (dependent on currently active diplexer frequency) |
| Upstream |
| Frequency range |
5 to 204 MHz (dependent on currently active diplexer frequency) |
| OFDMA channels |
≥2, per DOCSIS specification |
| Transmit level range (max) |
+61 to +48 dBmV depending on modulation format and number of bonded carriers, per DOCSIS specification |
| SC-QAM channels |
up to 8 per DOCSIS specification |
| MER |
| Specified range (with input level -5 to +20 dBmV) |
21 to 40 dB, 64 QAM; 28 to 40 dB, 256 QAM; 16 to 44 dB OFDM |
| Max displayable range |
50 dB |
| Resolution |
0.1 dB |
| Accuracy |
±2 dB typical at 25°C |
| Minimum lock level |
−15 dBmV |
| BER - ChannelCheck and DOCSISCheck Mode |
Down to 1E-9 (pre and post FEC) |
| BER - OneCheck mode |
Down to 1E-8 (pre and post FEC) default; 1E-9 user selectable |
| Interleaver depth |
128, 8 max |
| Display/Interface/Usability |
| High-brightness color LCD (800 x 480) |
5 inch diagonal |
| Touch screen |
Capacitive |
| Hard key navigation capable |
| Boot time |
Approximately 20 sec |
| Environmental |
| For indoor/outdoor use |
IP 54 light rain (0.5 in/hr; 1.27 cm/ hr) |
| Pollution |
2° |
| Drop |
1m (3.3 ft) onto concrete |
| Temp range |
Operating −10 to 50°C (14 to 122°F) Storage temp −20 to 60°C (-4 to 140°F) |
| Humidity |
10 – 90% RH non-condensing |
| RF immunity |
8.5 V/m (for CATV measurements) |
| Maximum altitude |
4000 m (13,123 ft) |
| Input/Outputs |
| RF (2) |
F connectors replaceable |
| Port 1 |
Downstream 54/85/108/258 MHz depending on diplexer |
| Port 2 |
Upstream 4 – 204 MHz and TDR |
| USB host (2) |
| Ethernet (2) |
RJ45 10/100/1000T |
| Power |
Polarized |
| Remote Access/Connectivity |
VNC accessible via IP address HTTPS file access via IP address Mobile application via Bluetooth |
| Battery |
| Field replaceable 96 W/hr 10.4 V, 10-cell LiIon |
| Typical battery life |
6 – 8 hr continuous, 15 – 20 hr typical usage |
| Battery charge time |
4 Hrs (90%) 6 - 8 Hrs 100% (AC charger) |
| StrataSync Reporting Capability |
Session based (job/work order) file saving of results gathered at TAP, GB, and CPE Measurement screen capture save and recall |
| StrataSync Core |
Asset and data management |
| StrataSync Plus |
Optional extended data management (6 years) |
| Weight |
| ONX-630 |
5.95 lb (2.7 kg) |
| Protective case and shoulder strap |
0.95 lb |
| WiFi |
| Test interface |
802.11 a/b/g/n (2.4/5 GHz) |
| Tests |
WiFi scan; WiFi access point (2.4 GHz only) |
| Scan results |
SSID (secure set identification); Channel; Security setting; Power level; MAC address |
| Scan modes |
AP list (access point); Channel graph; Time graph |
| Access point (IPX, TSX models only) |
Configure OneExpert CATV as WiFi access point (Ethernet to WiFi bridge) |