Locator Abutment & Retention Caps — Multi-System

This listing contains 3 different product groups — 73 options in total.
Choose the correct group first, then select your variant from the dropdown at the top of this page.

GroupWhat it isOptions
1. Locator AbutmentTitanium abutment for 11 implant platforms, GH 1–7 mm66
2. Locator Legacy AbutmentBioHorizons 3.0 mm internal hex only1
3. Retention Caps & Male InsertsReplacement caps and housings for standard Locator abutments6

Which Group Do I Need?

Ships from our US warehouse — fast domestic delivery, no customs wait, no import fees.

Group 1 — Locator Abutment (66 Options)

Select your implant platform first, then the gingival height. Locator abutments are platform-specific. Choosing the wrong platform means the abutment will not seat on the implant.

PlatformCompatible WithGH
Hiossen RHiossen ET, Osstem TS, DIO UF II, NeoBiotech, Cowell, INNO, CSM, Snucone1–7 mm
Hiossen MHiossen ET, Osstem TS, Snucone Mini1–6 mm
Zimmer 3.5Zimmer TSV 3.5, MIS Seven / M4 / Lance, BEGO, Cortex, Adin, ABT, BioHorizons1–7 mm
Zimmer 4.5Zimmer TSV 4.5, BioHorizons Internal / Tapered Pro / Tapered Plus1–6 mm
Straumann NCStraumann Bone Level, Bone Level Tapered1–7 mm
Straumann RCStraumann Bone Level, Bone Level Tapered1–7 mm
AnyRidgeMegaGen AnyRidge1–7 mm
Nobel NPNobelActive, NobelActive TiUltra, NobelParallel CC, NobelReplace CC1–5 mm
Nobel RPNobelActive, NobelActive TiUltra, NobelParallel CC, NobelReplace CC1–5 mm
AnyOneMegaGen AnyOne, Dentium, Dentis, SG3–5 mm
Neodent GMNeodent Grand Morse, Straumann Neodent GM1–6 mm

Note: the Neodent GM abutment is not compatible with the Helix GM Narrow platform. Different implant systems are not interchangeable.

How to Choose the Gingival Height

GH is the distance from the implant platform to the gingival margin. Measure with a periodontal probe before ordering:

1 mm GHThin tissue, minimal soft tissue thickness
2–3 mm GHMost common range — average tissue thickness
4–5 mm GHThicker soft tissue
6–7 mm GHVery thick tissue or deep placement

Abutment Specifications

MaterialTitanium Grade 5 (Ti-6Al-4V ELI), medical grade
TypeLocator abutment / overdenture attachment
ConnectionInternal conical connection, platform switching design
Gingival Height1 mm – 7 mm, platform dependent
Angle CorrectionUp to 40 degrees
Recommended Torque30 Ncm
Surface FinishGold anodized (batch dependent)
MachiningHigh precision CNC
Country of OriginChina
Package1 × abutment

Group 2 — Locator Legacy Abutment (1 Option)

BioHorizons 3.0 mm internal hex platform only.
  • BioHorizons Tapered
  • BioHorizons Tapered Plus
  • BioHorizons Tapered Pro

Legacy or Standard Locator on a BioHorizons Implant?

BioHorizons Tapered / Tapered Plus / Tapered Pro use a 3.0 mm internal hex. More than one of our abutments can fit these implants, so choose by the restoration you are building, not only by the implant brand:

Your caseChoose
Existing case already using Locator Legacy components; you are reordering the same abutmentGroup 2 — Legacy BioHor 3.0mm
New overdenture case on a BioHorizons implant, using the standard Locator attachmentGroup 1 — Zimmer 3.5 or Zimmer 4.5
Not sure which system the previous clinician usedMessage us with a photo of the existing abutment

Legacy and standard Locator components are not interchangeable. A Legacy cap will not seat on a standard Locator abutment, and the reverse is also true.

Legacy Specifications

SystemLocator Legacy
TypeLocator Legacy anchor abutment
Platform3.0 mm internal hex
ConnectionInternal hex
MaterialTitanium alloy Ti-6Al-4V ELI
ApplicationImplant-retained overdenture
Country of OriginChina
Package1 × Legacy abutment

Group 3 — Retention Caps & Male Inserts (6 Options)

Check your attachment system first.
These inserts fit the standard Locator attachment system only.
  • NOT compatible with Locator R-TX
  • NOT compatible with Locator Legacy
  • NOT compatible with other attachment systems
If you are not sure which system you have, message us before ordering.

Choose by Retention Force

OptionRetentionAngleBest For
Yellow0.8 lbsup to 40°Reduced retention cases, extended range
Blue1.2 lbsup to 20°Standard retention, everyday choice
Pink2.4 lbsup to 20°Maximum stability, high retention
BlackLaboratory only—Denture fabrication, replaced before delivery

Note: black caps are for laboratory processing only. They must be replaced with colored retention caps before clinical delivery.

Metal Housing & Lab Cap Assembly

Stainless steel housing with a black processing insert already installed, ready for laboratory processing. Sold as a 4-piece pack.

Assorted Kit — What You Get

Metal Housing× 1
Black Processing Cap× 1
Yellow Retention Cap (0.8 lbs)× 1
Blue Retention Cap (1.2 lbs)× 1
Pink Retention Cap (2.4 lbs)× 1
Block-Out Spacer× 1

Extended Range Male Inserts

Features — All Groups

Why Buy From Us

FDA Statement
 

The sale of this item may be subject to regulation by the U.S. Food and Drug Administration and state and local regulatory agencies. If so, you can bid on this item only if you are an authorized purchaser. If the item is subject to FDA regulation, I will verify your status as an authorized purchaser of this item before shipping of the item.

Seller's name:USDENT

City State: Zhengzhou, Henan China 

Telephone number:+86371-68618288

Datacaciques