APC AP8841 0U Vertical Metered Rack PDU 200-240V 30A (36) C13 (6) C19
Store Banner
Enterprise Power Distribution • Metered 2G Architecture

APC by Schneider Electric AP8841 Metered Rack PDU
Model: AP8841 | S/N Ref: 5A1724E04145 | 0U Vertical

200-240V | 30A (24A Derated) | NEMA L6-30P Input | 42 Outlets (36x C13 + 6x C19) | Real-Time Monitoring

Real-Time Active Power Metering for High-Density Datacenter Racks

The APC by Schneider Electric AP8841 (S/N: 5A1724E04145) is a high-density, zero-U (0U) vertical Metered Rack Power Distribution Unit designed for mission-critical IT infrastructure. Featuring active real-time power metering with user-defined alarm thresholds, it actively prevents circuit overloads. Equipped with 42 output receptacles (36x IEC 60320 C13 and 6x IEC 60320 C19) and fed by a heavy-duty NEMA L6-30P input plug (30A/208V-240V), this unit delivers up to 4.99kVA/5.76kVA of clean, monitored power across demanding enterprise enclosures without taking up valuable rack unit space.

⚠️

Electrical Input & Rack Form Factor Compatibility Notice

  • Input Plug & Voltage Requirement: This unit is fitted with a locking NEMA L6-30P (30A, 208V/240V) twist-lock plug. It requires a dedicated 200V–240V circuit and is NOT compatible with standard 120V household outlets (5-15P/5-20P).
  • 0U Vertical Dimensions (Height Requirement): The AP8841 measures approximately 70 inches (177.8 cm) in height. Please verify that your IT rack enclosure is at least 42U to 48U tall and features zero-U toolless mounting channels or compatible PDU brackets.
  • Metered Only (Non-Switched): This model features active aggregate power metering and remote network status reporting; it does NOT support remote outlet-level on/off switching.
  • Output Receptacles: Provides 36x IEC 320 C13 and 6x IEC 320 C19 outlets. Standard equipment power cables (e.g., C14-to-C13 or C20-to-C19 cords) are required and not included.

Key Architectural Advantages

Real-Time Power Metering

Active current draw monitoring via a built-in digital display and Web/SNMP interface ensures balanced load distribution and avoids circuit overloads.

High-Density 42-Outlet Layout

Features 36x IEC C13 and 6x IEC C19 locking-capable receptacles to power dense blade chassis, SAN storage arrays, and dual-corded servers.

Full Network Management

Integrated 10/100 Ethernet interface supports Web GUI, Telnet, CLI, SNMPv1/v2c/v3, and environmental sensor expansion (temperature/humidity).

Zero-U Toolless Mounting

Mounts vertically in standard rack channels via quick-mount pegs, preserving 100% of usable U-space for compute, storage, and networking hardware.

Comprehensive Technical Specifications

Feature / Parameter Specification Details
Brand & Manufacturer APC by Schneider Electric
Model Number AP8841
Serial Number Reference 5A1724E04145
PDU Type / Series Metered Rack PDU (Generation 2 Architecture)
Form Factor & Mounting 0U Vertical Rackmount (Toolless button mount / bracket compatible)
Nominal Input Voltage 200V / 208V / 230V / 240V AC (Single Phase, 50/60 Hz)
Input Connection Type NEMA L6-30P (30A Twist-Lock Plug) with attached 10 ft (3.0 m) power cord
Current Ratings Maximum: 30A | Regulatory Derated Input: 24A
Load Capacity 4992 VA (at 208V) / 5760 VA (at 240V)
Output Receptacles 42 Total: (36) IEC 60320 C13 + (6) IEC 60320 C19
Network Interface & Protocols RJ-45 10/100 Base-T, HTTP/HTTPS, SNMPv1/v2c/v3, Telnet, SSH, Syslog
Local Interface Two-digit multi-segment LED display showing real-time current draw & alarms
Dimensions (H x W x D) Approx. 70.5 in x 2.2 in x 1.7 in (179.1 cm x 5.6 cm x 4.4 cm)
Regulatory Compliance UL 60950-1, cUL Listed, CSA C22.2, FCC Part 15 Class A, RoHS
Testing & Diagnostics 100% Tested / Receptacle Voltage Verified / NIC Reset & Firmware Verified

✓ What Is Included

  • 1x APC AP8841 0U Vertical Metered Rack PDU (S/N: 5A1724E04145)
  • Integrated 10 ft (3m) Heavy-Duty Power Cord with NEMA L6-30P Plug
  • Pre-installed 0U Toolless Mounting Pegs / Buttons

✕ What Is NOT Included

  • C13 / C19 Equipment Power Cables (Jumper cords)
  • Environmental Temperature/Humidity Sensor Probe (AP9335T)
  • Server Rack Enclosure / Cabinet
  • Original Retail Box & Paper Documentation
🛡️

30-Day Functionality Guarantee

Every PDU undergoes electrical continuity testing on all 42 receptacles, display panel verification, and network management card diagnostics. Network settings are restored to factory defaults ready for your datacenter deployment.

📦

Freight-Safe Specialized Packaging

Due to its 70-inch length, this unit is shipped in a reinforced, heavy-duty cardboard corrugated tube/carton with custom foam cushioning and tracking coverage to guarantee it arrives straight, undamaged, and ready to mount.

Enterprise Server & Storage Components • Fully Tested Hardware • Fast & Secure Dispatch