Patient Monitor CMS5100  New Free

 Shipping 

   DESCRIPTION

 The CMS5100 patient monitor is a feature-rich monitoring device that can be applied to adults, children, and newborns. The user can choose different measurement parameters according to different needs. The patient monitor can monitor NIBP, SpO2, and PR. Integrates parameter measurement and display function into a compact, lightweight patient monitor suitable for all levels of hospitals, community medical services, and home use.


Features


1) Be applicable for NIBP and SpO2 monitoring in adults, pediatric and newborns of all ages, easy to operate and very cost-effective;
2) Be applicable for medicine, surgery, operating room, ICU/CCU, emergency room, obstetrics and gynecology, pediatrics;
3)Compact and flexible appearance, easy to carry and suitable for indoor and outdoor monitoring (by ambulance);
4) Built-in rechargeable lithium polymer battery, which ensures uninterrupted monitoring;
5) Perfect menu design, easy to use interface;
6)Show the measurement result of SYS, DIA, MAP, SpO2, PR and bar graph on the high brightness digital tube screen;
7) 2.8'' (320×240) true color TFT LCD screen, displays time information, SpO2 plethysmogram, alarm condition, trend chart, system list and settings, etc.;
8) Visual and audible alarm for SYS, DIA, MAP, SpO2 and PR, and alarm upper and lower limit can be configured as needed;
9) Independent non-volatile memory, storage for up to 2000 NIBP data groups and 78,000 SpO2 data groups;
10) Convenient and fast to review measurement data, available to review 24 hour NIBP trend chart and 22 hour SpO2 trend chart.

Performance


1 PNI
Using oscillometry technology, also called oscillography technology, to measure blood pressure.
1) Measuring mode: manual/automatic/continuous
2)Measuring interval in automatic mode: 1, 2, 3, 4, 5, 5×n(n=2, 3, 4...51) min.
3)Resolution: 1mmHg
4)Accuracy: maximum average error: ±5mmHg; maximum standard deviation: 8mmHg.
5)Overpressure protection: dual protection for both software and hardware
6)Others: restart, self-test and static pressure precision test
7)Measuring range:

Adult
SIS 40mmHg~270mmHg
PAM 20mmHg~235mmHg
Diameter 10mmHg~215mmHg
Pediatric:
SIS 40mmHg~200mmHg
PAM 20mmHg~165mmHg
Diameter 10mmHg~150mmHg
Newborn:
SIS 40mmHg~135mmHg
PAM 20mmHg~110mmHg
Diameter 10mmHg~100mmHg
2 SpO2
Use of photoelectric oxyhemoglobin inspection technology combined with pulse recording and scanning technology ability to measure blood oxygen saturation.
1)Measuring range: 0%~100%
2)Alarm range: 0%~100%
3)Resolution: 1%
4)Accuracy: 70%~100%, ±2%, below 70% unspecified.
3 PR
Use of photoelectric oxyhemoglobin inspection technology combined with pulse recording and scanning technology ability to measure pulse rate.
1)Measuring range: 25 bpm~250 bpm
2)Alarm range: 25 bpm~250 bpm
3) Resolution: 1 bpm
4)Accuracy: ±2 bpm or ±2%, whichever is higher
4 Safety and power supply
1)Power supply: rated voltage: ~220V, rated power: 50Hz
2) Safety rating: Class I equipment, BF type defibrillation proof applied part

Add-ons
1) 1 piece user manual (GB only) on request for other language
2) Power cable 1 unit
3) Power adapter 1 unit
4)SpO2 sensor 1pc
5)1 piece adult NIBP sleeve
6) 1 piece NIBP extension tube

Physical Feature
Dimensions: 190 mm (length) × 162 mm (width) × 240 mm (height)
Weight: about 1.6 kg