Dental Ultrasonic Piezo Surgery TipS LC2 BS1 Fit Satelec Acteon Piezotome 2 Cube

Description
Friction resistant and Long life.
 
Fit:
Acteon Satelec Piezotome 2.
Acteon Satelec Piezotome Solo (LED).
Acteon Satelec Piezotome Cube.
Acteon Implantcenter 2.
 
Description:  
 
Bone Surgery Kit
 
Thinness and security.
Bone Surgery™ (BS) tips, principally intended for performing bone grafts, allows cutting, excising and remodeling of bone structures without the risk of soft tissue lesions.
Comprising six ultrasonic tips (three saws and three scalpels) adapted to the different cases that arise in the intraoral environment, the BS Kit is used for dental clinical treatments such as bone harvesting, crest expansion, preparation of the implant site and accessing the lower alveolar nerve.
The sterile spray helps to cool the tips (thus avoiding tissue damage from exposure to high temperatures) and provides excellent visibility of the operating field.
These tips guarantee a fine, clean and effortless cut.
V-BS1:Saw intended for cutting of cortical bone in surgical orthodontics, pre-implant surgery,and bone distraction.
V-BS2L: Bone saw with four teeth, used for cutting the ramus cortical bone. Left  oriented, it is used to create vertical and horizontal osteotomy lines on the patient’s right mandible.
V-BS2R: Bone saw with four teeth, used for cutting the ramus cortical bone. Right  oriented, it is used to create vertical and horizontal osteotomy lines on the patient’s left mandible.
V-BS5: Flat scalpel, for fine osteotomies. Ridge expansion, thin osteotomy, distraction, preparation of buccal bone flap on thick cortical bone prior to sinus lift surgery.
V-BS4: Circular scalpel angled at 130°, for osteoplasty and harvesting of bone particles or chips. Ridge osteoplasty, periodontal surgery, cysts exerisis, etc.
V-BS6: Curved scalpel particularly effective for substantial osseous reshaping. This tip is used to perform osteoplasties and reshaping of the bone not assuring the tooth support. It can also be used to mark a prosthetic reference point on enamel, if needed, where osteoplasty will begin.
 
Extraction Kit
 
For atraumatic extractions without bone destruction.
This kit is intended for clinical procedures such as extraction of wisdom teeth, fractured roots, impacted teeth and root section. The five ultrasonic tips are each adapted to the anatomical context (reduced visibility and space) of anterior and posterior areas.
Inserted between the cementum and the periodontal ligament of the tooth, the tips will widen the ligamental space. Once separated from its attachment system, the tooth can be removed rapidly and with a less traumatic luxation. The alveolar bone edge can be kept intact; an alveolectomy is therefore avoided.
Usage guidelines recommendations:
- The tip must be activated before its insertion into the periodontal space.
- The tip must be placed parallel to the root.
- Perform a to-and-fro movement towards the apex.
- It is important not to exert a lever effect with the tips.
LC1: To be inserted deeply and with great care, along the periodontal ligament, between the root and the alveolar bone.Length of active part: 9mm
LC1/90: To be inserted deeply and with great care, along the periodontal ligament, between the root and the alveolar bone. Length of active part: 9mm.
LC2:The particularly slim LC2 allows access to the tight spaces between the root and the alveolar bone without risk of damaging cortical bone. Length of active part: 10mm
LC2L: Oriented at 45° to the left or to the right, the LC2L/LC2R facilitates access to the posterior areas. The tip’s slimness respects the morphology of cortical bone and offers working comfort in the sectors with reduced visibility.Length of active part: 10mm
LC2R: Oriented at 45° to the left or to the right, the LC2L/LC2R facilitates access to the posterior areas. The tip’s slimness respects the morphology of cortical bone and offers working comfort in the sectors with reduced visibility.Length of active part: 10mm
 
Sinus Lift Kit
 
For unmatched visibility.
The Sinus Lift Kit offers the practitioner a straightforward and safe answer to the lateral sinus lift operation. Thanks to the ultrasonic frequency modulation, the risk of membrane damage is limited.
The diamond-coated tips for window cutting and the three spatula tips for sinus lift SL1 and SL2 are cooled by the sterile spray (thus avoiding tissue damage from exposure to high temperatures). The use of a manual instrument is recommended to control the membrane detachment.
Moreover, the cavitation effect enables excellent visibility of the operating field.
These tips guarantee a fine, clean and effortless cut.
V-SL1: Diamond-coated tip for vestibular bone window cut and for attenuation of sharp angles.
V-SL2: Diamond- coated ball tip for smoothing the vestibular bone window and precise osteoplasty. Ball diameter: 1.5mm. Laser mark every 2mm.
V-SL3: Plateau-tip, non- cutting, for sinus membrane elevation on the vestibular bone window’s edges.Plateau diameter: 5 mm.
V-SL4: Non-cutting spatula, oriented at 90°, for sinus membrane elevation inside the sinus.Spatula diameter: 4 mm.
V-SL5: Non-cutting spatula, oriented at 135°, used for sinus membrane elevation inside the sinus and for disengagement of anatomical structures.Spatula diameter: 4 mm.
Sinus Lift Kit:V-SL1 V-SL2 V-SL3 V-SL4 V-SL5 & tip holder
 
Essential Kit
 
Simply essential.
This kit is a selection of the most popular tips from SATELEC, an Acteon group company® surgical kits.
These 6 tips can be used in all of the following procedures:
- Osteotomy, osteoplasty (BS1 and BS4 tips)
- Extractions (LC2 tip)
- Sinus Elevation by the lateral approach (SL1, SL2 and SL3 tips)
Due to the ultrasonic frequency modulation, a selective cut is achieved in surgical mode. Therefore, these tips limit the risk of soft tissue injury such as gingiva, ligaments, periodontal fibers and nerves. The sterile spray helps to cool the tips.
V-BS1:Saw intended for cutting of cortical bone in surgical orthodontics, pre-implant surgery,and bone distraction.
V-BS4: Circular scalpel angled at 130°, for osteoplasty and harvesting of bone particles or chips. Ridge osteoplasty, periodontal surgery, cysts exerisis, etc.
V-LC2:The particularly slim LC2 allows access to the tight spaces between the root and the alveolar bone without risk of damaging cortical bone. Length of active part: 10mm
V-SL1: Diamond-coated tip for vestibular bone window cut and for attenuation of sharp angles.
V-SL2: Diamond- coated ball tip for smoothing the vestibular bone window and precise osteoplasty. Ball diameter: 1.5mm. Laser mark every 2mm.
V-SL3: Plateau-tip, non- cutting, for sinus membrane elevation on the vestibular bone window’s edges.Plateau diameter: 5 mm.
30 Days Money Back Guaranteed, We pay return shipping.

 

FDA Statement

The sale of this item may be subject to regulation by the U.S. Food and Drug Administration and state and local regulatory agencies. If so, you can bid on this item only if you are an authorized purchaser. If the item is subject to FDA regulation, I will verify your status as an authorized purchaser of this item before shipping of the item.


Feedback
 
We commited ourselfs to your 100% satisfaction both with our goods and services.

• Please leave me FIVE star POSITIVE feedback if you are satisfied with our items.

• Please leave me message immediately before leave us neutral feedback or negtive feedback, We will try our best to resolve any problem for you untill you are satisfied.

Shipping
 
Shipping: Import duties, taxes and charges are not included in the item price or shipping charges. These charges are the buyer's responsibility. 
 
The goods you odered will be posted out in the second working day after the paymet has been made. (We will inform you via email if any delay occured due to holiday events.

General shipping time is between 7-12 working days. (After the shipping started, the order will be monitored and the track of the item will be posted on paypal)

 
Returns
 
If the item you received is damaged or defective,Please Send message to me immidately.We will free exchange or refund.

We will pay the return shipping costs if the product is defective or the return is a result of our error. If the item is returned for any other reason you are responsible for the return shipping charges.

You can return your purchase for up to 15 days from the date of delivery. No refund will be issued if the product shows signs of use. Returned package must be in the original packaging, everything must be in new condition, No missing parts.

Our guarantee does not cover accidental damage or wear of product caused by customer.Thank you very much for your understanding!
 
Send message to me

 

If you have any questions, please Send message to me via ebay message system!

We're one of the largest online dental suppliers based on many qualified manufacturers in china.

If you Send message to me immediately after placing the order, we will make every effort to assist you with your change request. Unfortunately, we can not make changes or cancel an order once it has shipped.

Any help,need or questions, please do not hesitate to Send message to me. Looking forward to our friendly & win-win cooperation!

 

 
DataCaciques