Maximum Supply Voltage 3.7 volts_of_direct_current
Specific Uses For Product Professional
Upper Temperature Rating 20 °C
Material Type Plastic
Style Name Infrared Sensor
Item Dimensions 3.3 x 1.5 x 7.9 inches
Item Weight 14.88 ounces
Model ILD-200
Number of Items 1
Warranty Description 1 Year
Unit Count 1 Count
Included Components ILD-200M (IR Sens. ≤0.14 oz/yr)
Part Number ILD-200
Item dimensions L x W x H 3.3 x 1.5 x 7.9 inches
Material Plastic
Style Infrared Sensor

Product description

1 HVAC/R Leak Detector 2 Why Infrared Sensor 3 Easy to use

Application of Infrared Technology Improves the Accuracy of Your Detection

Advanced Infrared Refrigerant Leak Detector, Awesome HVAC/R Job Partner

Anti-interference

More Accurate Detection Results

Minimize false alarms from other chemicals

Pump Suction

No direct-contact with refrigerants. Longer life than heated diode

Detect More Refrigerants

Detect All Halogenated Refrigerants.

HFCs, HCFCs, CFCs, PFCs, HFOs, HCs.

Zero Point Calibration

Reset to max sensitivity in clean air

Reset to current sensitivity in refrigerants environment to detect higher concentration leakages

Sensor Life 10 years Max Sensitivity 0.14 oz/yr Response Time ≤ 1s Preheating Time 30s Refrigerant Types CFC/HFC/HCFC/HFO Package Included 1 x Leak Detector, 1 x Packet of Filters, 1 x USB Cable, 1 x UV light Screen 2.8" TFT LCD display Auto OFF 10 minutes without operation Operating Temperature -10°C to 52°C (14°F to 125.6 °F) Operating Humidity 50%~85%RH Storage Temperature -20°C to 60°C (-4°F to 140 °F) Weight 0.93 ibs Size 7.9*3.3*1.5 inches Battery 3.7V 3000mAh rechargeable lithium battery, full charge for 6 hours continuous work
  • What are the features of the infrared IR sensor in ILD-200/300?

    The infrared IR sensor's sensitivity remains stable for 10 years, unaffected by humidity or oil, and nearly equal for most refrigerants. It detects concentration changes, so the wand must keep moving.

  • What are the features of the heated diode sensor in ILD-100H?

    The heated diode sensor detects absolute concentration levels, allowing sustained beeping at leaks and high initial sensitivity. However, it loses sensitivity over time, requires replacement, and shows varied sensitivity to refrigerants.

  • How long does the sensor last?

    If it seems like your leak detector is no longer picking up leaks or is not as sensitive as it was when you first bought it, try replacing the filter. This should fix the issue. If this does not fix the issue try replacing the sensor.

  • Why is it necessary to move during the detection process?

    As ILD series are designed to detect the relative concentration of gases, that if the detected concentration remains unchanged in the stationary environment, it will not be able to pinpoint the leakages.

  • Why does the product alarm when not in a leaking environment?

    1. Deformation of the optical chamber affects detection data, a normal occurrence.

    2. Loose critical optical filters, we could provide repair assistance.

    3. Check for routers or devices causing electromagnetic interference.

1 Leak Detector Series 2 Refrigerant Scale Series 3 Manifold Gauge Series 4 Vacuum Pump Series 5 Pressure & Vacuum Gauge
  • Infrared Leak Detector: Compared with the heated diode leak detector, the infrared refrigerant leak detector has strong anti-interference ability, faster response speed, more accurate and longer service life.
  • Higher Sensitivity: Adjustable sensitivity with High/Medium/Low levels and the maximum sensitivity is up to 0.14oz/yr.
  • Detecting All Halogenated Gases: It can detect all kinds of halogen refrigerants including CFCs, HFCs, HCFCs, HCs, HFOs and mixed refrigerants such as R11/R22/R404a/R410a/R600a/R1234yf and Blends such as AZ-50, HP62, MP39 etc.
  • 2.8' Large Screen: Do not missing any leakage. The peak display clearly indicates the orientation of the leak detection point and provides users with a quiet working environment.
  • US Local Team R&D and Service: We offer 24/7 customer service and technical support.

HVAC Refrigerant Leak Detector 10 Yrs Infrared Sensor Life, Halogen Freon Sniffer, Air Conditioning Detection, Automotive Gas Finder, ILD-200

ABOUT US

We offer the best prices around on high quality products. Our E-store includes media such as books, movies, music and games while offering electronics, toys, sporting apparel, clothing, tools, general home, garden items and more.

SHIPPING

We are always working hard to ensure your package arrives as soon as possible. Please understand that some factors like weather, high postal traffic, and the performance of shipping companies are outside of our control.

We offer free shipping to the lower 48 states and ship within 2 business days of payment, usually sooner. We do not accept P.O. Boxes. Please provide a physical address.

For shipping outside of the continental USA, we only use eBay's Global Shipping Program.The item is shipped to KY and then sent to the rest of the world. International customers are responsible for all duties and taxes. Continue to check out in order to calculate costs for shipping the item to your country. Messages regarding eBay's Global Shipping Program MUST be directed at eBay EXCLUSIVELY.

RETURNS

We offer a 30-Day Return Policy on items which you are not completely satisfied with. You have the option for a full-refund or an exchange of the item. No returns are available on items shipped outside of the USA.

PAYMENT

We accept PayPal.

CONTACT US

This page content is yet to come
Please ad us to your favorite seller and visit again later
Thank You

CUSTOMER SATISFACTION

We try our very best to make sure every customer is completely satisfied. If there's a problem, message us! We're happy to help.