***Inverter Air Conditioners are much more energy efficient than their non-inverter counterparts: they can save up to 30% on electricity compared to non-inverters. Non-inverter air conditioners use the on/off method, where the compressor is switched on and off at regular intervals to maintain the desired temperature. An inverter AC has a variable speed compressor, while a non-inverter AC has a fixed speed compressor. Variable speed compressors are more energy efficient than their fixed counterparts and make less noise as well.
 
 
12,000 BTU Mini Split 21.3 SEER2 INVERTER Ductless Air Conditioner Heat Pump 110V
●WORKS WITH ALEXA: Use voice or app control to control your air conditioner from anywhere.Worls with wifi ,
you can use app on your smart phone control your air conditioner from anywhere

●Ultra efficient cooling and heating 12,000 BTU/h capacity with 21 SEER Certified AHRI Certified & ETL Certified
 (Includes about 16 FT Line Set)

●Ultra capable performance: Heating during -13°F weather and cooling during 122°F weather Pre-Charged R-410A

●DESIGNED FOR HOME & BUSINESS: Powerful performance and dependable durability with high quality design for 
an attractive appearance Ultra silent operation: as quiet as 34 dB on the indoor section and 52 dB on the outdoor unit

●WHAT’S INCLUDED: Includes indoor air handler, outdoor condensers and installation kit with 16ft. line set and
 communication wire. Important note: requires professional installation.
 
 
 
SPEC
      12000BTU 
BasicInformation Indoor Market Model   AAG22-12H1A
Outdoor Market Model   AAG22-12H1B
Country/Area   United States
Configuration Code    
Power supply   V-Hz-Ph 115V,60Hz,1Ph
Voltage range V 103.5-126.5
NationalCertification Cooling Capacity Btu/h 12000
Cooling Input W 1200
Cooling Current A 12.3
SEER2 Btu/h/W 21.4
EER2 Btu/h/W 10.0
Cooling Capacity Range Btu/h 3800~12600
Cooling Input (range) W 400 ~ 1280
Cooling Current(range) A 3.6 ~12.8
Heating Capacity Btu/h 12000
Heating Input W 1116
Heating Current A 11.4
HSPF2-4 Btu/h/W 8.7
HSPF2-5 Btu/h/W 6.7
COP W/W 3.15
Heating Capacity Range Btu/h 2730~12500
Heating Input(range) W 320 ~1180
Heating Current(range) A 3.6 ~12.0 
Heating(H32) Rated capacity Btu/h 7800
Heating(H32) COP W/W 2.30
Heating(H42) Rated capacity Btu/h 7000
Heating(H42) COP W/W 1.85
Cooling at 109 F (43) Rated capacity Btu/h 9300
Cooling at 5 F (-15) Btu/h 13000
Heating at 17F (-8.33) Rated capacity Btu/h 8100
Heating(H42)  5F(-15) Rated capacity Btu/h 7000
Heating at -4F (-20) Rated capacity Btu/h /
Heating at -13F (-25) Rated capacity Btu/h /
Heating at -22F (-30) Rated capacity Btu/h /
Moisture removal L/h 1.3
Indoor MINIMUM  CIRCUIT  AMPACITY A 3.0
Indoor MAX.FUSE A 15
Outdoor MINIMUM  CIRCUIT  AMPACITY A 19.0
Outdoor MAX.FUSE A 20
Connection wiring   14#x4
Indoor Indoor fan motor RLA A 0.6
Outdoor Outdoor fan motor RLA A 0.6
Outdoor Compressor Rated current(RLA) A 14.0
Indoor Indoor air flow (Turbo/Hi/Mi/Lo/Si) m³/h 600 / 500 / 400 / 300 / 220
Indoor Indoor air flow (Turbo/Hi/Mi/Lo/Si) CFM 353.2 / 294.3 / 235.4 / 176.6 / 129.5
Indoor noise level (Turbo/Hi/Mi/Lo/Si) dB(A) 45.0/41.0/37.0/27.5/18.5
Outdoor noise level (Hi) dB(A) 52.5
Outdoor Outdoor air flow CFM 1235.3
Outdoor Outdoor air flow m³/h 2100
BasicParameter(NC)  N.A. Design pressure PSI 550 / 340
Outdoor Refrigerant type   R454B
Outdoor Refrigerant charge kg 0.69
Outdoor Refrigerant charge oz 24.34
Outdoor Additional charge per metre g/m 15
Outdoor Additional charge per feet oz/ft 0.16
Outdoor Throttle type   Capillary
Liquid side mm(inch) 6.35mm(1/4in)
Gas side mm(inch) 9.52mm(3/8in)
Max. refrigerant pipe length m 25
Max. Piping Length ft 82.00
Max. difference in level m 15
Max. Height Difference ft 49.20
Room  temperature_Indoor(cooling) 16~32
Room  temperature_Outdoor(cooling) -15~50
Room  temperature_Indoor(heating) 0~30
Room  temperature_Outdoor(heating) -15~24
Indoor Operating Temp. Range(Cooling) 60~90
Outdoor Operating Temp. Range(Heating) 5~75
Indoor Operating Temp. Range(Heating) 32-86
Outdoor Operating Temp. Range(Cooling) 5~122
Size/Weight Indoor Item Net/Gross weight kg 8.8/11.6
Indoor Item Net/Gross weight lb 19.40/25.57
Indoor Body Dimension W×D×H mm 802.0×200.0×295.0
Indoor Unit Dimension WxDxH inch 31.57 x 7.87 x 11.61
Indoor Item Package Dimension(W×D×H) mm 875×285×380
Indoor Package Dimension WxDxH inch 34.45 x 11.22 x 14.96
Outdoor Item Net/Gross weight kg 27.8/30.4
Outdoor Item Net/Gross weight lb 61.29/67.02
Outdoor Body Dimension W×D×H mm 765.0×303.0×555.0
Outdoor Unit Dimension WxDxH inch 30.12 x 11.93 x 21.85
Outdoor Item Package Dimension(W×D×H) mm 887×337×610
Outdoor Package Dimension WxDxH inch 34.92 x 13.27 x 24.02
ElectricalMotor Indoor Indoor Fan Motor Model   ZKFP-20-8-113
Indoor output W 20
Indoor Motor Speed(Hi/Mi/Lo) r/min 850/750/450
OutdoorElectricalMotor Outdoor Outdoor Fan Motor Model   ZKFN-34-10-1-3
Outdoor Outdoor Fan Motor Output W 34
Outdoor Outdoor Fan Motor Speed(Hi/Mid/Lo) r/min 780/700/600
OutdoorElectricalMotor2 Outdoor Outdoor Fan Motor Model   NA
Outdoor Outdoor Fan Motor Input2 W NA
Outdoor Outdoor Fan Motor Speed(Hi/Mid/Lo)2 r/min NA
Compressor Outdoor Compressor Type   ROTARY
Outdoor Compressor Model   KSN98D64UFZ3
Outdoor Compressor Brand   GMCC
Outdoor Compressor Capacity W 3,100
Outdoor Compressor Input Power W 765
Outdoor Compressor Rated current A 4.65
Outdoor Refrigerant oil   VG74
  Outdoor Refrigerant oil/oil charge mL 300

 
 
 
 
 
 
 
PushAuction


On Jul 3, 2026 at 00:21:27 PDT, seller added the following information: