Diverse terminals, more functions for you to choose.- supports external potentiometer control (connect the "FOR" and "DCM" terminals,than set PD001=1)
- supports mcah3 function and RS-485 communication
- (For more information, you can contact the seller, we will send you a video of the basic functions of VFD)
| Key Function- UP: Progressively increase data or function codes.
- DOWN: Progressively decrease data or function codes.
- SET: Enter menus step-by-step, save setting parameters.
- PRGM: Exit current(or present) state, switch among each states, mainly used to switch monitoring state, exit to previous menu.
- FWD/REV: 1, Press momentary button to start,release to stop; 2 Switch the rotation direction
- SHIFT: Switch monitoring parameters at monitoring state, at secondary menu, move data box to process editing position.
- Kindly Note: If you want to show RPM in the display,please press 'SHIFT' key
| Advanced motherboard features- PID control; advanced calculus PID closed-loop arithmetic, quick responding speed and high suitability
- Easy PLC function can realize 16 legs of speed and inverter control function
- RS485 communication port, adopting standard international MODBUS main circuit control
- With extremely strong anti-jamming capability
- Low output ratting torque0.5HZ-150%, low speed running ability
- Carrier adjustable by 16KHZ, completely soundless working environment
- Broad voltage working area, normal running in 304V-456V
- Auto voltage regulation (AVR) technique, for ensuring the inverter load capability
- With perfect error protection and short circuit starting protection capability
|