28 GHz RF Converter MA80001A
RF Input/Output Connector
Port 1, Port 2
Connector: K (m)
Impedance: 50Ω (nom.)
VSWR (when transmitted): ≤2.5 (23.75 GHz ≤ frequency ≤ 30 GHz)
VSWR (when received): ≤2.5 (23.45 GHz ≤ frequency ≤ 30.3 GHz)
Transmission Characteristics
Frequency
Setting range: 24.25 GHz to 29.5 GHz (Center frequency setting range of measurement software)
Setting resolution: 1 Hz
Accuracy: Depend on accuracy of MT8000A reference oscillator
Level
Setting range: –90 to +5 dBm
Setting resolution: 0.1 dB
Accuracy: ±1.5 dB (+18°C to +28°C, after Cal, with CW)
Signal purity
Non-harmonic spurious
With CW, maximum output level
≤–40 dBc (non-harmonic on setting frequency ±500 MHz, non-harmonic, exclude setting frequency ±50 MHz)
≤–30 dBc (23.75 GHz ≤ non-harmonic frequency ≤ 30 GHz, exclude setting frequency within ±500 MHz and –4500 MHz)
Maximum modulation bandwidth: 1 GHz
Receiving Characteristics
Frequency
Setting range: 24.25 GHz to 29.5 GHz (Center frequency setting range of measurement software)
Setting resolution: 1 Hz
Level
Maximum input level: +20 dBm, 0 VDC (with CW)
Setting range: –70 to+5 dBm
Setting resolution: 0.1 dB
Amplitude
Measurement resolution: 0.01 dB
Measurement accuracy: At the signal equal to the setting frequency and the setting level
After Cal, with CW, 24.25 GHz ≤ setting frequency ≤ 29.5 GHz, measurement bandwidth 100 MHz, +18°C to +28°C
±1.5 dB (–50 dBm ≤ setting level ≤ +5 dBm)
±2.5 dB (–70 dBm ≤ setting level < –50 dBm)
IF Input/Output Connector
Connect to MT8000A: B
Connector: N (f)
Impedance: 50Ω (nom.)
External Control Connector Round multiway type connector
DC Input Connector Voltage: 12 VDC
Current: ≤3 A
Dimensions and Mass Dimensions: 92 (W) × 175 (H) × 260 (D) mm (excluding projections)
Mass: ≤6 kg
Environmental Conditions Operating temperature range: +5°C to +40°C (without condensation)
Storage temperature range: –20°C to +71°C (without condensation)
CE
EMC 2014/30/EU, EN61326-1, EN61000-3-2
LVD 2014/35/EU, EN61010-1
RoHS 2011/65/EU, (EU) 2015/863, EN IEC 63000: 2018
UKCA
EMC S.I. 2016 No.1091, EN 61326-1, EN61000-3-2
LVD S.I. 2016 No.1101, EN 61010-1
RoHS S.I. 2012 No.3032, EN IEC 63000:2018