Product description

Tailored to Specific Models

Stanbroil Control Board Replacement for Pit Boss Grill

Control board features three full PID programmes, identified as A45, A70 and A99, tailored to specific models to ensure precise and consistent temperature control throughout the cooking process on these models:

  • A45: Suitable for PB440D2 and PB550G.
  • A70: Suitable for PB820 and PB850G.
  • A99: Suitable for Pro 1100 and PB1150G.
  • "ErL" Error Code: Ignition Failure. Check if pellets in the hopper are sufficient or if the igniting rod is faulty.
  • "ErH" Error Code: Smoker Overheating. Press and hold the Power Button to turn off. After cooling, restart and set the desired temperature.
  • "Err" Error Code: Temperature Probe Disconnected. Inspect the Temperature Probe wires and ensure the spade connectors are firmly and correctly attached.
  • "noP" Error Code: Faulty Connection at Port or Damaged Meat Probe/Control Board. Check if the port connection is secure and inspect components for faults.