Universal Prosthetic Implant Screwdrivers Kit #1 Hand Drivers

Description:
  • Universal Prosthetic Kit, including 1 torque wrench & 16 drivers.
  • Autoclavable case
  • Medical Grade Stainless Steel
Features:
  • Torque wrench:10-17Ncm
  • Long driver: 25mm
  • Short driver: 20mm
  • Hex 1.0 drivers: Compatible Ankylos
  • Hex 1.19 drivers: Compatible Anthogyr
  • Hex 1.2 drivers: Compatible Osstem, 3I, Megagen, Neobiotech, Datsing
  • Hex 1.25 drivers: Compatible Cortex
  • Hex 1.27 drivers: Compatible Dentium, Dentis, BEGO, Astra, KJ MEDITECH, Zimmer, MIS, Cortex, Adin, Biohorizon,  Alpha Bio Tech
  • Hex 1.4 drivers: Compatible ICX
  • T5 drivers: Compatible Nobel
  • T6 drivers: Compatible Straumann
Universal Prosthetic Implant Screwdrivers Kit #2 Latch Drivers

Description:
  • Used for implant surgery and restoration, technicians preparing crowns, etc.
  • Our original Universal Prosthetic Driver Kit compatible with most major implant manufacturers and less known one from all around the world.
Package including:
  • 1 pc wrench
  • 16 pcs  drivers
  • 1 pc adapter
  • The drivers can be worked with implant contra angle, Surgident SD-TORQUE. And with the adapter, the drivers can be used with the torque ratchet manually.
Features:
  • Universal Torque Ratchet & Drivers Kit
  • Torque Wrench: 15-70Ncm  (15, 30, 45, 70Ncm)
  • Long driver: 30mm
  • Short driver: 23.5mm
  • Totally 16 drivers, compatible with different implant system (Short drivers+Long drivers)
  • Medical grade stainless steel 
  • Autoclavable case
Drivers compatible with:
  • 1.0  Hex Drivers (2pcs Long+ Short): Compatible with Ankylos
  • 1.19  Hex Drivers (2pcs Long+ Short): Compatible with Anthogyr
  • 1.2  Hex Drivers (2pcs Long+ Short): Compatible with Osstem, 3I, Megagen, Neobiotech, Dating
  • 1.25  Hex Drivers (2pcs Long+ Short): Compatible with Cortex
  • 1.27  Hex Drivers (2pcs Long+ Short): Compatible with Dentium,  Dentis, BEGO, Astra, KJ, MEDITECH, Zimmer, MIS, Cortex, Adin, Biohorizon, Alpha Bio Tec
  • 1.4 Drivers (2pcs Long+ Short): Compatible with ICX
  • T5 Drivers (2pcs Long+ Short): Compatible with Nobel
  • T6 Drivers (2pcs Long+ Short): Compatible with Straumann
Universal Prosthetic Implant Abutment Drivers Kit #3

Similar to 37448 Prosthetic Kit from Nobel Biocare
Upgraded model, with more screwdrivers & abutment drivers, compatible with more brands

Item Description
  • Drivers with different colors, easy to identificate
  • 12 drivers, compatible with abutment or abutment screw with different brands
  • With driver holder, no slipping, no dropping, easy access
Driver 
  • This tool is used to tighten an abutment or abutment screw.

Item number

Specification

Compatible

Hex 1.0

Hex 1.0*24mm

Ankylos

Hex 1.2

Hex 1.2*24mm

Osstem, DIO,Bioconcept BV,3I, Megagen, ICM, C-Tech,Neobiotech, Datsing

Hex 1.25

Hex 1.25*24mm

Cortex, Ticare, ABT, Zimmer

Hex 1.27

Hex1.27*24mm

Dentium, Dentis, BEGO, Astra, KJ MEDITECH, Zimmer, MIS, Cortex, Adin, Biohorizon, Alpha Bio Tech, Camlog

T5

T5*24mm

Nobel

T6

T6*24mm

Straumann

Hex 2.4

7.55*20mm

OSSTEM 4.0, Stud Abutment

Hex 3.3

7.55*20mm

Osstem 4.8 Abutment

Octa 3.0

7.55*20mm

OSSTEM 5.0 Abutment

Triangle

7.55*20mm

OSSTEM Port Abutment

Hex 3.2

7.55*20mm

Dentium 4.5, 5.5 Abutment

Square

7.55*20mm

Dentium Min Ball Abutment


Driver Holder
  • Holding a hex driver, this tool is used when tightening an abutment or abutment screw intraorally
Torque Ratchet
  • Tightening hex driver and measuring torque
  • As changing tip direction, tightening and loosing can be controlled

Sinus Lift Kit DASK (Golden burs kit is Korean made DASK / Black burs kit is GSM brand, made in China)

Simple & easy access to sinus cavity • Broad exposure of bony walls with special instruments
DASK is an advanced sinus lifting kit. The drills are internally irrigated, designed to create hydraulic pressure that protects the sinus membrane when drilling.
The DASK kit contains 3 drills for the lateral approach, 3 drills for the crystal approach, 4 drill stoppers and 4 sinus hand instruments.
The drills are internally irrigated to create an umbrella effect to reduce the risk of a potential perforation to the sinus.

       DASK Drill #1    XRT 332035
Crestal Approac      DASK Drill #2    XRT 372035
                                DASK Drill #3  XED 331035D

     DASK Drill #4    XRT 064025
Lateral Approach    DASK Drill #5    XRT 084025
                                DASK Drill #6  XST 083025
* DASK Drill #1~5 : Drill speed 800 to 1,200 rpm, 30~45Ncm with internal irrigation
   DASK Drill #6 : Drill speed 800 to 1,200 rpm, 30~45Ncm with external irrigation

Stopper For XRT332035, XRT372035, XED331035D
Drilling DepthLArt.No.

08    10.6    XFDST 08
06    12.6    XFDST 06
06    14.6    XFDST 04
02    16.6    XFDST 02

Sinus Elevation Instrument
Art. NO
XSE1L
XSE2L

XSE3L
XSE4L

GSM SRK Screw Remove Kit

Screw Remover Kit is a surgical tool developed in order safely and quickly to remove screws that have become fractured inside an implanted Fixture for various reasons. After removing the Screw, a new Abutment may be connected to the Fixture.
Remove Fractured Screw, Screw Remover!
No Worries About Fractured Screw.

Components

1. Claw

This is a surgical tool that removes a screw that has become fractured inside the Fixture.
After selecting the size that is appropriate for the size of the screw that is to be removed, it must be used by connecting a guide to the Fixture (Conical/Internal/External Guide). Then it is connected to the Shank Driver, and the fractured screw can be removed by rotating by hand in the reverse direction. If the fractured screw cannot be removed using the Claw, it must be removed using the Reverse Drill and the Screw Remover.

 

 Product Name

Fractured Screw size 

Product Name 

Fractured Screw size 

CD16

 M1.6

 CD20

 M2.0

CD18

 M1.8

 CD25

 M2.5

 
2. Reverse Drill

 - This is a tool that creates a hole on the fractured face of the Screw that will be used by the Screw Remover.
 - After selecting the appropriate Reverse Drill for the size of the screw that needs to be removed, it must be used by connecting a guide for the fi xture (Perfect/ Conical/Internal/External Guide). The depth of the drill can be adjusted from 1 mm to 3 mm, because the Drill body has markings.

 - The removal of an M1.6 size Screw Should utilize the Claw.
 - Although diff erent manufacturers produce diff erent sizes of abutment screws, except in rare cases, typically they utilize screws of Size M1.6, M1.8, M2.0, or M2.5. (‘M’ stands for a metric screw. The number indicates the external size of the screw. For example, “M1.6 Screw” indicates that it is a metric screw the external diameter of  Which is 1.6 mm). 


 Product Name

 Diameter(Ø)

 Fractured Screw size

 RCD10

 Ø 1.0

 M1.8

 RCD12

 Ø 1.2

 M1.8

 RCD14

 Ø 1.4

 M1.8


3. Screw Remover

 - This is a device that removes a fractured screw. Insert a Screw Remover that is appropriate for the size of the hole that has been formed using the Reverse Drill and rotate at a low speed (at or below 80 rpm) in the reverse direction.
 - The Screw Remover was designed in a tapered shape so as to increase, as it turns, the amount of friction, which is necessary to loosen the Screw.

 

 Product Name

Diameter (Ø)

Fractured Screw size 

 SR10

 Ø 1.0

 M1.8

 SR12

 Ø 1.2

 M2.0

 SR14

 Ø 1.4

 M2.5


4. Shank Driver

 - This is a surgical tool that was designed to be connected to the Screw Remover to allow the use of the hand, Torque Wrench, or Ratchet. 

 

 Product Name

Standard 

Applicable Products 

 SHD00

 for Hand or Ratchet

 Screw Remover

(SR10, SR12, SR14)


5. Perfect Guide & PG Hand Driver

 - The Perfect Guide acts as a Guide for the Reverse Drill. It is used when the screw is fractured at the lower part of the female screw inside the Fixture. It is connected to PG Hand Driver and is directly applied to the Fixture female Screw.

 - The Perfect Guide can be safely used because it has a stop structure inside that prevents the Reverse Drill from drilling more than 2 mm.


6. Conical, Internal, External Guide

 - They act as the Guide when using the Reverse Drill. They are used when the Perfect Guide cannot be used, or if the screw was fractured at a location deeper than 2 mm into the lower part of the female screw inside the Fixture.
 - The Guide appropriate for connecting to the Fixture must be selected.
 


7. SR Driver Holder

This can be easily affixed to the Fixture by connecting it to the 3.5 Double Hex part of the Conical, Internal, or External Guide.


PY-FSRK Fixture & Screw Removal Kit

The usage of the SOS implant remover kit is easy and convenient just insert a remover tip into the implant until it is tight then make use of the hand adaptor or remover wrench to extract the implant from the socket.
 
Capable of removal and replacement of implants in ill-positioned placement cases. It helps to remove broken screws without damaging the implant. A perfect solution with the best results. All is done with minimal trauma to the patient and without any surgical interference.
  • Both Osseo integrated implants and fractured implants are simply removed.
  • No bone damage or trauma to patients.
  • No need to use a trephine drill.
  • Applicable to any type of implant with a screw hole.
  • Capable to remove and replace the implant in an ill-positioned implant placement case.
  • Helps to remove broken screws without damaging the implant.
  • Fit virtually any implant system external hex, internal hex, conical connection, and more.
  • Removes failed implants without compromising surrounding bone or damaging neighboring structures.
If you buy kit, you will get
  • screw remove drill
  • screw remove tap
  • screw remove bar
  • screw remove guide sub non-hex 22N
  • screw remove guide sub non-hex 16N
  • screw remove guide sub. hex 2.5
  • screw remove guide sub. hex 2.1
  • fixute remove f 22°
  • fixure remove 16°
  • fixure remove 16° N
  • cover screw remove
  • ratcher wrench
Screw Remove Drill
  • This is the tool to take out the broken screw by turning in reverse way.
Screw Remove Tap
  • This is the tool to take out the broken screw by turning in reverse way.
Screw Remove Bar
  • This tool is for taking out broken screw through picking up.
Screw Remove Guide
  • Instruments to guarantee the screw remove drill can be stable working in the center of broken screw.
Fixture Remove
  • To take out useless fixture by bone loss or broken, use this by locking in reverse way.
Cover Screw Remove
  • This is the tool after making the hole like slot shape and turn in reverse way to take out.
Ratchet Wrench
  • Use this attaching with the fixture remove and the cover screw remove for when you put your fingers to screw.
MCTBIOTECH FSRK-02 Fixture & Screw Removal Kit

Made in South Korea by MCTBIO

The implant fixture and fractured screw removal kit is the only kit you need to remove failed dental implants and fractured screws. 
Our new Next Generation Kit features 7 extra parts at the same unbeatable price! Watch videos below.
Remove a fractured/broken screw and save the implant, or
Remove a failed implant while minimizing trauma to the bone.

kit include the following items
  • Fixture removal drills FRD-01 (mini), FRD-02 (regular), FRD-03 (Wide), Adapter 1
  • Screw removal guide 3i Internal NP, 3i Internal RP, External mini, External Regular, ITI Octa, Nobel Replace Tri-Lobe RP, Nobel Replace Tri-Lobe WP, Nobel Replace Tri-Lobe NP, Zimmer TSV 3.7/4.7, Zimmer TSV 5.7, Astra Hex, Noble Active NP, Noble Active RP, FRW-01 Wrench
  • Screw Removal Drill & Tap SRD-01, SRT-01, SRT-02 (Wide), SRA-01(Adapter)
  • Fixture Removal Trephine Bur FRT-3.7/4.4 (Ø3.5), FRT-3.9/4.6 (Ø3.7), FRT-4.3/5.0(Ø4.1), FRT-4.7/5.4 (Ø4.5), FRT-5.2/5.9 (Ø5.0), FRT-5.7/6.4 (Ø5.5), FRT-6.2/6.9 (Ø6.0), SRG-H, Adapter H
HIOSSEN Bone Profilers Implant Prosthetic Kit
  • Torque Wrench 1 piece
  • Torque Driver 1.2 S 1 piece
  • Torque Driver 1.2 L 1 piece
  • Hand Driver 1.2 S 1 piece
  • Hand Driver 1.2 L 1 piece
  • Multi Abutment Outer Driver 1 piece
  • Multi Abutment Machine Driver 1 piece
  • Bone Profiler 4.0 1 piece
  • Bone Profiler 5.0 1 piece
  • Bone Profiler 6.0 1 piece
  • Guide Screw Regular 1 piece
  • Guide Screw Mini 1 piece
  • Autoclavable PPSU box 1 piece
Torque Wrench - Bar Type
  • Adjusts the implant depth, and tightens abutments, screws, etc.
  • Pull the bar back until the desired torque value is reached
  • torque value 10 20 30
Torque Driver
  • Driver for torque wrench
  • Tip holding function
  • May bend or break if excessive torque is applied
  • Damage is possible even at low torque if not fully engaged
  • Apply vertical pressure when applying torque driver (Do not tilt)
  • If the tip is bent or stripped, replace immediately
  • Hex 1.2, fit Hiossen Osstem
  • Torque driver 1.2 S: 15mm
  • Torque driver 1.2 L: 20mm
Hand Driver
  • Manual driver
  • Tip holding function
  • Hex 1.2, fit Hiossen, OSSTEM
  • Hand driver 1.2 S: 13mm
  • Hand driver 1.2 L: 18mm
Machine Screw Driver
  • 1.2 hex driver for engine handpiece
  • Short 23.5mm (overall length)
  • Long 30mm (overall length)
Multi Abutment Outer Driver
  • Torque driver for Multi-Abutments
Multi Abutment Machine Driver
  • Machine driver for Multi-Abutments
Bone Profiler
  • Used to remove bone around the implant after first or second stage surgery
  • Connect the Guide Screw to the implant in order to center the profiler
  • Guide screw protects the implant's platform from damage
  • Packing unit : bone profiler + guide screw (Mini & Regular) 
FDA Statement

The sale of this item may be subject to regulation by the U.S. Food and Drug Administration and state and local regulatory agencies. If so, do not bid on this item unless you are an authorized purchaser. If the item is subject to FDA regulation, I will verify your status as an authorized purchaser of this item before shipping of the item.