Overview
it continues the compact and lightweight concept but with a new generation of 3 in 1 multifunction tester: oscilloscope, signal source and multimeter; A small volume of the non-profit grip by a single hand; The suspendingstand was designed to support multi-angle adjustment; Ultra-low-power, Type C charging interface, each 2 hours battery charge allow working one full day or standbytwo months; High-definition color LCD screen display clear and delicate; Minimalist keyboard design simplifyoperation, easy to use.
Features
-Intelligent charging control: Its lithium batteries can be recharged byeither high current-5V/2A or ordinary computer USB interface. Allow while charging, while using, very convenient and handy;
-Ultra-low power design: Type C charging interface, after every recharge of 2 hours, the device can be used continuously for a full day or standby more than two months;
-Large-capacity lithium battery power supply: 18650 replaceable lithium battery power system, free from replace battery;
-5V/2A charger + Type C charging cable: Type C power + data transfer interface, can share the charger and data cable with your mobile phone;
-AUTO one-key test: Magic tool and essential function for test newbie;
-Volume small, one hand holding: The 45 degree suspension bracket design provide you a work station anywhere anytime;
-One key page out, quick compare two groups of reference waveforms + 6 groups of waveforms storage, simple and effective;
-Digital voltmeter function: automatic frequency and amplitude measurement, convenient and worry-free;
-Its cursor measurement functionsupports time and voltage manual measurement, and measure the required waveforms accurately;
-One-click switching its Chinese and English language menu;
-Color LCD screen: exquisite and smooth lines make the waveforms clear and undistorted when magnify;
-Minimalist keyboard design simplify operation, convenient to use;
-Unibody casing: fine touch feeling, favorable impact resistance, outstanding heat resistance, easy to disassemble;
-Self-calibration function: free from level drift after long time unused;
-Universal multimeter function: voltage, current, resistance, diode, capacitor, on-off test;
-Waveform generator output function: output sine, square, triangle, trapezoidal and other waveforms; sine up to 25MHz;
-Function of video help:scan code on back of machine to get help of video course;
-The PC software supports windows7/8/10 32-bit and 64-bit.
Specification
|
Model |
2D72 |
2D42 |
2C72 |
2C42 |
|
|
Oscilloscope Mode |
|||||
|
Bandwidth |
70MHz |
40MHz |
70MHz |
40MHz |
|
|
Channel |
2CH+DMM+AWG |
2CH+DMM+AWG |
2CH+DMM |
2CH+DMM |
|
|
Horizontal |
|||||
|
Sample Rate Range |
250MSa/s(Single-channel), 125MSa/s(Dual-channel) |
||||
|
Waveform Interpolation |
(sin x)/x |
||||
|
Record Length |
Max. 6K for single-channel; 3K samples per dual-channel |
||||
|
SEC/DIV Range |
5ns/div~500s/div 1, 2, 5 sequence |
||||
|
Vertical |
|||||
|
A/D Converter |
8-bit resolution,each channel sampled simultaneously |
||||
|
VOLTS/DIV Range |
10mV/div~10V/divat input BNC |
||||
|
Bandwidth Limit, typical |
20MHz |
||||
|
Low Frequency Response (-3db) |
≤10Hz at BNC |
||||
|
Rise Time at BNC, typical |
≤5ns |
||||
|
DC Gain Accuracy |
±3% for Normal or Average acquisition mode, 10V/div to 10mV/div |
||||
|
Note: Bandwidth reduced to 6MHz when using a 1X probe. |
|||||
|
Acquisition |
|||||
|
Acquisition Modes |
Normal |
||||
|
Trigger |
|||||
|
Type |
Edge |
||||
|
Mode |
Auto, Normal, single |
||||
|
Level |
±4 divisions from center of screen |
||||
|
Trigger Level Accuracy |
0.2div × volts/div within ±4 divisions from center of screen |
||||
|
Slope |
Rising, Falling, Rising & Falling |
||||
|
Source |
CH1/CH2 |
||||
|
Input |
|||||
|
Coupling |
DC, AC or GND |
||||
|
Input Impedance, |
25pF±3 pF, 1MΩ±2% |
||||
|
DC coupled |
|||||
|
Probe Attenuation |
1X, 10X |
||||
|
Supported Probe Attenuation Factors |
1X, 10X, 100X, 1000X |
||||
|
Maximum Input Voltage |
150VRMS |
||||
|
Measurement |
|||||
|
Cursor |
Voltage difference between cursors: △V |
|
|||
|
Time difference between cursors: △T |
|||||
|
Automatic Measurements |
Frequency, Amplitude |
||||
|
Arbitrary Waveform Generator Mode |
|||||
|
Waveform Frequency |
Sine: 1Hz~25MHz |
- |
- |
|
|
|
Square: 1Hz~10MHz |
- |
- |
|||
|
Ramp: 1Hz~1MHz |
- |
- |
|||
|
EXP: 1Hz~5MHz |
- |
- |
|||
|
Sampling |
250MSa/s |
- |
- |
||
|
Amplitude |
2.5Vpp(50Ω) |
- |
- |
|
|
|
5Vpp(High impedance) |
- |
- |
|||
|
Frequency Resolution |
0.10% |
- |
- |
||
|
Channel |
1CH waveform output |
- |
- |
||
|
Waveform Depth |
512Sa |
- |
- |
||
|
Vertical Resolution |
12 bit |
- |
- |
||
|
Output Impedance |
50 Ω |
- |
- |
||
|
DMM |
|||||
|
Maximum Resolution |
4000 Counts |
||||
|
DMM Testing Modes |
Voltage,Current,Resistance,Capacitance,Diode &On-Off |
||||
|
Maximum Input Voltage |
AC:600V, DC: 600V |
||||
|
Maximum Input Current |
AC: 10A, DC:10A |
||||
|
Input Impedance |
10MΩ |
||||
|
Measurement Term |
Range |
Accuracy |
Resolution |
||
|
DC Voltage |
400.00mV |
± (0.8% + 5) |
100uV |
|
|
|
4.000V |
1mV |
||||
|
40.00V |
10mV |
||||
|
400.0V |
100mV |
||||
|
600.0V |
± (1% + 2) |
1V |
|||
|
Overload protection: 400mV: 250V, other: 600Vrms. |
|||||
|
AC Voltage |
4.000V |
± (1.2% + 5) |
1mV |
|
|
|
40.00V |
10mV |
||||
|
400.0V |
100mV |
||||
|
600.0V |
±(1.5% + 5) |
1V |
|||
|
Frequency: 40Hz~400Hz; |
|||||
|
Frequency of 400V and 600V: 40Hz~100Hz |
|||||
|
DC Current |
40.00mA |
± (1% + 2) |
10uA |
|
|
|
200.0mA |
± (1.5% + 2) |
100uA |
|||
|
4.000A |
± (1.8% + 2) |
1mA |
|||
|
10.00A |
± (3% + 2) |
10mA |
|||
|
Overload protection: |
|||||
|
self restoring fuse: 200mA/250V, 4A and 10A range no fuse. |
|||||
|
AC Current |
40.00mA |
± (1.3% + 2) |
10uA |
|
|
|
400.0mA |
± (1.8% + 2) |
100uA |
|||
|
4.000A |
± (2% + 3) |
1mA |
|||
|
10.00A |
± (3% + 5) |
10mA |
|||
|
Frequency: 40Hz~400Hz; |
|||||
|
self restoring fuse: 200mA/250V, 4A and 10A range no fuse. |
|||||
|
Resistance |
400.0Ω |
±(1% + 3) |
0.1Ω |
|
|
|
4.000KΩ |
±(1.2% + 5) |
1Ω |
|||
|
60.00KΩ |
10Ω |
||||
|
400.0KΩ |
100Ω |
||||
|
4.000MΩ |
1KΩ |
||||
|
40.00MΩ |
± (1.5%±3) |
10KΩ |
|||
|
Overload protection: 220Vrms |
|||||
|
Capacitance |
40.00nF |
±(3% + 5) |
10pF |
|
|
|
400.0nF |
100pF |
||||
|
4.000uF |
1nF |
||||
|
40.00uF |
10nF |
||||
|
100.0uF |
100nF |
||||
|
Overload protection: 220Vrms |
|||||
|
Diode |
0V~1.0V |
||||
|
On-Off |
<50Ω |
||||
|
General Specifications |
|||||
|
Display |
|||||
|
Display Type |
2.8 inch64K color TFT |
||||
|
Display Resolution |
320 horizontal by 240 vertical pixels |
||||
|
Display Contrast |
Adjustable |
||||
|
Power Supply |
|||||
|
Supply Voltage |
100V-240VAC, 50Hz-60Hz; DC INPUT: 5VDC, 2A |
||||
|
Power Consumption |
<2.5W |
||||
|
Fuse |
T, 3A |
||||
|
Battery |
2600mA*2 |
||||
|
Environmental |
|||||
|
Operating Temperature |
0~50 °C (32~122 °F) |
||||
|
Storage Temperature |
-40~+71 °C (-40~159.8 °F) |
||||
|
Humidity |
≤+104℉(≤+40°C): ≤90% relative humidity |
|
|||
|
106℉~122℉ (+41°C ~50°C): ≤60% relative humidity |
|||||
|
Cooling Method |
Convection |
||||
|
Altitude |
Operating and |
3,000m (10,000 feet) |
|
||
|
Nonoperating |
|||||
|
Mechanical Shock |
Random Vibration |
0.31gRMS from 50Hz to 500Hz, 10 minutes on each axis |
|
||
|
Nonoperating |
2.46gRMS from 5Hz to 500Hz, 10 minutes on each axis |
||||
|
Operating |
50g, 11ms, half sine |
||||
|
Mechanical |
|||||
|
Dimension |
199 x 98x 40mm (L x W x H) |
||||
|
Weight |
624g |
||||
|
Standard Accessories |
Probe*1,Clip Probe*2, Type Charging Cable*1, Power Adapter*1, Multimeter Probe*1 |
Probe*1,Clip Probe*2, Type Charging Cable*1, Power Adapter*1, Multimeter Probe*1 |
Probe*1,Clip Probe*1, Type Charging Cable*1, Power Adapter*1, Multimeter Probe*1 |
Probe*1,Clip Probe*1, Type Charging Cable*1, Power Adapter*1, Multimeter Probe*1 |
|