(Americas Only) 5-9.6kW | Split Phase
AC-Coupled HV Retrofit Inverter
UL certified
GoodWe’s A-BP Series is designed to supplement an existing
on-grid PV system and connect with high voltage batteries
to seamlessly upgrade to a full storage system. The inverter
can boost the PV system without the grid, ensuring the
grid-tied inverter stays connected if the grid is compromised.
With frequency shifting, the A-BP can regulate the output
power of the grid-tied inverter and change the AC frequency
to prevent over charging the battery. With an inbuilt smart
meter and plug & play AC connectors, the inverter is easy
to install. The A-BP can support whole home backup and is
compatible with various brands of grid-tied inverters.
| Model | GW7600A-BP | |||||
| Battery Input | ||||||
| Battery Type | Li-Ion | |||||
| Nominal Battery Voltage (V) | 360 | |||||
| Battery Voltage Range (V)*1 | 80 ~ 495 | |||||
| Max. Continuous Charging Current (A) | 50 | |||||
| Max. Continuous Discharging Current (A) | 50 | |||||
| Max. Charging Power (W) | 7600 | |||||
| Max. Discharging Power (W) | 7980 | |||||
| AC Output (On-grid) | ||||||
| Nominal Apparent Power Output to Utility Grid (VA) | 7600 | |||||
| Max. Apparent Power Output to Utility Grid (VA) | 7600 | |||||
| Max. Apparent Power from Utility Grid (VA) | 9120 | |||||
| Nominal Output Voltage (V) | 240 | |||||
| Output Voltage Range (V) | 211 ~ 264 | |||||
| Nominal AC Grid Frequency (Hz) | 60 | |||||
| Max. AC Current Output to Utility Grid (A) | 31.7 | |||||
| Max. AC Current From Utility Grid (A) | 38 | |||||
| Power Factor | ~1 (Adjustable from 0.8 leading to 0.8 lagging) | |||||
| Max. Total Harmonic Distortion | <3% | |||||
| AC Output (Back-up) | ||||||
| Back-up Nominal Apparent Power (VA) | 7600 | |||||
| Max. Output Apparent Power (VA)*2 | 7600 (9120@60sec) | |||||
| Max. Output Current (A) | 31.7 | |||||
| Nominal Output Voltage (V) | 240 / 120 | |||||
| Nominal Output Frequency (Hz) | 60 | |||||
| Output THDv (@Linear Load) | <3% | |||||
| Efficiency | ||||||
| Max. Battery to AC Efficiency | 96.6% | |||||
| Protection | ||||||
| PV Insulation Resistance Detection | Integrated | |||||
| Residual Current Monitoring | Integrated | |||||
| Battery Reverse Polarity Protection | Integrated | |||||
| Anti-islanding Protection | Integrated | |||||
| AC Overcurrent Protection | Integrated | |||||
| AC Short Circuit Protection | Integrated | |||||
| AC Overvoltage Protection | Integrated | |||||
| General Data | ||||||
| Operating Temperature Range | -31°F ~ +140°F (-35°C ~ +60°C) | |||||
| Relative Humidity | 0 ~ 95% | |||||
| Max. Operating Altitude | ≤13123ft (4000m) | |||||
| Cooling Method | Smart Fan Cooling | |||||
| User Interface | LED, WLAN + APP | |||||
| Communication with BMS | RS485, CAN | |||||
| Communication with Meter | RS485 | |||||
| Communication with Portal | Wi-Fi, LAN (Optional) | |||||
| Weight | 70.5lb (32kg) | |||||
| Dimension (W × H × D) | 16.3 × 31.1 × 6.9 in (415 × 790 × 175 mm) | |||||
| Noise Emission (dB) | <45 | |||||
| Topology | Non-isolated | |||||
| Self-consumption at Night (W)*3 | <20 | |||||
| Ingress Protection Rating | Type 4X | |||||
| Mounting Method | Wall Mounted | |||||
| Certification | ||||||
| Grid Interconnection | UL1741 SA, California Rule 21, HECO Rule 14, IEEE 1547, IEEE 1547.1 | |||||
| Safety Regulations | UL 1741, CSA 22.2 No. 107-01, UL 1998, UL991, UL1699B | |||||
| Electromagnetic Compatibility | FCC part15 CLASS B | |||||
Conditions:
Warranty:
Payment:
Shipping:
Terms of Sale:
About Us: