New Hioki DT4282 Digital Multimeters Dmm Handheld Tester Meter 60000 Count
|
|
|
| NOTES BEFORE PLACING ORDERS |
|
|
|
Our price excludes any destination customs duties or taxes. Whether you pay duties at clearance depends on local law.
|
In some countries, eBay collects sales tax. The final price on the order settlement page prevails.
Please confirm your shipping details (address, postcode, phone, and contact person) before ordering. To ship to a different address, let us know in advance and leave a message in the transaction.
We aim for positive feedback and a 5-star DSR on every transaction. If you're considering neutral or negative feedback or a lower DSR, please contact us first so we can address your concerns.
Our team focuses on providing high quality products with reasonable price and tries its best to keep transactions as simple as possible. Please be confident of and enjoy your shopping here! |
|
|
| DESCRIPTION |
|
|
 |
|
|
Specification:   
The Hioki DT4200 Digital Multimeter Series consist of a complete lineup of 9 models ranging from professional to industrial to pocket types. The DT4282 is a high-precision 60,000 count DMM with direct 10A input and all of the functions and features required for advanced testing in laboratories and R&D.   
|
| 60,000 count, 5-digit display, high-resolution measurements. |
| ±0.025% DC V basic accuracy, wide 20 Hz to 100 kHz AC V frequency characteristics. |
| Low-pass filter cuts high harmonics (when measuring inverter fundamental waveforms). |
| Includes multiple measurement functions such as DC+ACV, temperature, capacitance, and frequency. |
| Includes terminal shutter mechanism for accident prevention (prevents erroneous test lead insertion). |
| USB communications function supports PC measurements (optional). |
| Broad -15 (5°F) to 55°C (131°F) operating temperature range. |
| Basic specifications (Accuracy guaranteed for 1 year). |
|
|
Regarding DMM Accuracy:   
Due to the many ranges and functions available in a DMM, only the basic accuracy is indicated for reference. Please refer to the individual catalogs for detailed accuracy information.   
|
| DC voltage | 60.000 mV to 1000.0 V, 6 ranges, Basic accuracy: ±0.025 % rdg. ±2 dgt. |
|---|
| AC voltage 45 to 65 Hz | 60.000 mV to 1000.0 V, 6 ranges, Frequency characteristics: 20 Hz - 100 kHz Basic accuracy: ±0.2 % rdg. ±25 dgt. (True RMS, crest factor 3) |
|---|
| DC + AC voltage 45 to 65 Hz | 6.0000 V to 1000.0 V, 4 ranges, Frequency characteristics: 20 Hz - 100 kHz Basic accuracy: ±0.3 % rdg. ±30 dgt. (True RMS, crest factor 3) |
|---|
| Resistance | 60.000 Ω to 600.0 MΩ, 8 ranges, (Conductance: 600.00 nS, DT4282 only) Basic accuracy: ±0.03 % rdg. ±2 dgt. |
|---|
| DC current | 600.00 μA to 10.000 A, 6 ranges, Basic accuracy: ±0.05 % rdg. ±5 dgt. |
|---|
| AC current 45 to 65 Hz | 600.00 μA to 10.000 A, 6 ranges, Basic accuracy: ±0.6 % rdg. ±5 dgt. (True RMS, crest factor 3) Frequency characteristics: 20 Hz - 20 kHz (at 600 μA to 600 mA range) |
|---|
| AC Current (use with Clamp on probes) 40 to 1 kHz | N/A |
|---|
| Peak | DC V measurement: Signal width 4 msec or more (single), 1 msec or more (repeated) AC V, DC/AC A measurement: Signal width 1 msec or more (single), 250 μsec or more (repeated) |
|---|
| C (capacitance) | 1.000 nF to 100.0 mF, 9 ranges, Basic accuracy: ±1.0 % rdg. ±5 dgt. |
|---|
| Continuity Check | Continuity threshold: 20/50/100/500 Ω, Response time: 10 ms or more |
|---|
| Diode test | Open terminal voltage: 4.5 V or less, Testing current 1.2 mA or less, Threshold of forward voltage: 0.15 V to 3 V, seven stages |
|---|
| Frequency | AC V, DC+AC V, AC A measurement, at pulse width 1 μs or more (50 % duty ratio) 99.999 Hz (0.5 Hz or more) to 500.00 kHz, 5 ranges, ±0.005 % rdg. ±3 dgt. |
|---|
| dB conversion | Standard impedance setting (dBm), 4 Ω to 1200 Ω, 20 stages Display dB conversion value of AC voltage (dBV) |
|---|
| Temperature | K: -40.0 °C to 800.0 °C (-40.0 °F to 1472.0 °F) (use with optional probe DT4910) Add accuracy of the Thermocouple probe to main unit accuracy: ±0.5 % rdg. ±3 °C |
|---|
| Other functions | Filter function (Remove harmonic noise, use only at 600 VAC, 1000 VAC ranges), Display value hold, Auto hold, Max/Min value display, Sampling select, Relative display, Measurement memory (400 data), Auto-power save, USB communication (option), 4-20 mA % conversion |
|---|
| Display | Main and Sub displays: 5-digits LCD, max. 60000 digits |
|---|
| Display refresh rates | 5 times/s (Capacitance measurement: 0.05 to 2 times/s, depending on measured value, Temperature: 1 time/s ) |
|---|
| Power supply | LR6 (AA) alkaline batteries ×4, Continuous use: 100 hours |
|---|
| Dimensions and mass | 93 mm (3.66 in) W × 197 mm (7.76 in) H× 53 mm (2.09 in) D, 650 g (22.9 oz) (with test leads holder and batteries) |
|---|
| Accessories | Test Lead L9207-10 ×1, Instruction Manual ×1, LR6 Alkaline Battery ×4 |
|---|
|