• Please check fitment notes & description for accurate information.
  • 2001-2004 Toyota Sequoia 4.7L 2000-2004 Toyota Tundra 4.7L
  •  
  • Oxygen Sensor's Location:
  •  
  • How do I know the O2 sensor is good or not?
    • Check engine light on
    • A reduction in fuel economy.
    • Your catalytic converter fails unexpectedly
    • Exhaust emissions reach undesirable levels.
  • How to install the oxygen sensor?
  • Step 1 - Some sensors are equipped with a heat shield that must be removed before the sensor removal, this is performed by removing any mounting bolts.
  •  
  • 4pcs for Toyota Sequoia Tundra 2001-04 Upstream Downstream O2 Oxygen Sensor

    Please check fitment notes & description for accurate information.

    2001-2004 Toyota Sequoia 4.7L
    2000-2004 Toyota Tundra 4.7L

     

    Oxygen Sensor's Location:

     

    How do I know the O2 sensor is good or not?

    • Check engine light on

    • A reduction in fuel economy.

    • Your catalytic converter fails unexpectedly

    • Exhaust emissions reach undesirable levels.

    How to install the oxygen sensor?

    Step 1 - Some sensors are equipped with a heat shield that must be removed before the sensor removal, this is performed by removing any mounting bolts.

     

    Step 2 - By using a regular socket it minimizes potential damage to the sensor body and the threads, this technique helps avoid stripping the old sensor upon removal.

     

    Step 3 - Then, locate and disconnect the wiring connector, this step should be done before removing the sensor if the wiring is still attached.

     

    Step 4 - Its important that the wiring harness connectors are exactly the same, each sensor is unique to it's position and is located in the system by its connector configuration. (Note: some replacement sensors have a universal electrical connector that must be configured to the wiring of the old sensor.)

     

    Step 5 - Use a small wire brush to help clean the threaded port to ensure a proper seal of the new sensor. Gently install the new oxygen sensor by hand while keeping the wiring and connector free from bends.

     

    Step 6 - Gently tighten the sensor while keeping wiring free from damage, these sensors need to be fairly snug to avoid leakage.

     

    Step 7 - Once the sensor is tightened, reinstall any heat shields or bracing that had to be removed.

     

    Step 8 - After the heat shield has been reinstalled, mount the connector to it's holder and reattach the connector back onto the wiring harness. If the car has diagnostic trouble codes, they will need to be cleared.

     

     

    Must Know Before Buying:

    The following information is for instructional and guidance reference only. We try and make them as accurate as we can.

     

    If Check Engine Light is on or an OBDII Trouble/Fault code occurs after installation, check the sensor with a voltmeter as below. 
    If the sensor is good, further diagnosis is required. There're many different codes for specific functional failures, which are NOT necessarily relevant to the sensor. Find out what the Code means before leaving any feedbacks.

     

    Items that have been installed, altered or contaminated are non-returnable.

    1. ONLY a defective sensor after tested by a voltmeter is applied to manufacturer warranty.
    2. 20% restocking fee is required if buyer bought wrong items due to not paying attention to fitment information and ask for return.

     

    The Price, Quality & Functionality of the O2 Sensor is fully covered under our warranty & return policy. However, refund for any labor cost, expense in a dealer shop or damage due to wrong installation is NOT covered.


    Item Specifics
    Country of Origin United States
    Brand WFLNHB
    Fitment Type Direct Replacement
    Warranty Yes
    Manufacturer Part Number CB991905S00
    Number of Pieces 4
    Interchange Part Number ASG823, A13441, AES20194, A234-4162, A234-4169
    Other Part Number A-234-4161, A-SG1838, A-13095, A-ES20072
    Other Part Number 2 AA8946534120, AA8946534130, AA8946534140, AA8946534150
    Modified Item No
    Universal Or Specific Fit Specific
    Thread Size M18
    Wires 4
    Hex Size 7/8 in
    Housing Material Metal
    Technology Narrow-band
    Custom Bundle Yes
    Position Upstream, Downstream
    Attachment Method Screw-On
    Terminal Type Blade
    Heated Yes
    Automotive Color / Finish Steel
    Placement on Vehicle Before After Catalytic Converter
    Bundle Description Include 4 Piece Oxygen Sensor

    Payment

    Returns

    Shop Category
    Picture
    Help & Info
    Payment Policy
    Shipping Policy
    Return Policy
    FAQ
    About Us
    4pcs for Toyota Sequoia Tundra 2001-04 Upstream Downstream O2 Oxygen Sensor

    Please check fitment notes & description for accurate information.

    2001-2004 Toyota Sequoia 4.7L
    2000-2004 Toyota Tundra 4.7L

     

    Oxygen Sensor's Location:

     

    How do I know the O2 sensor is good or not?

    • Check engine light on

    • A reduction in fuel economy.

    • Your catalytic converter fails unexpectedly

    • Exhaust emissions reach undesirable levels.

    How to install the oxygen sensor?

    Step 1 - Some sensors are equipped with a heat shield that must be removed before the sensor removal, this is performed by removing any mounting bolts.

     

    Step 2 - By using a regular socket it minimizes potential damage to the sensor body and the threads, this technique helps avoid stripping the old sensor upon removal.

     

    Step 3 - Then, locate and disconnect the wiring connector, this step should be done before removing the sensor if the wiring is still attached.

     

    Step 4 - Its important that the wiring harness connectors are exactly the same, each sensor is unique to it's position and is located in the system by its connector configuration. (Note: some replacement sensors have a universal electrical connector that must be configured to the wiring of the old sensor.)

     

    Step 5 - Use a small wire brush to help clean the threaded port to ensure a proper seal of the new sensor. Gently install the new oxygen sensor by hand while keeping the wiring and connector free from bends.

     

    Step 6 - Gently tighten the sensor while keeping wiring free from damage, these sensors need to be fairly snug to avoid leakage.

     

    Step 7 - Once the sensor is tightened, reinstall any heat shields or bracing that had to be removed.

     

    Step 8 - After the heat shield has been reinstalled, mount the connector to it's holder and reattach the connector back onto the wiring harness. If the car has diagnostic trouble codes, they will need to be cleared.

     

     

    Must Know Before Buying:

    The following information is for instructional and guidance reference only. We try and make them as accurate as we can.

     

    If Check Engine Light is on or an OBDII Trouble/Fault code occurs after installation, check the sensor with a voltmeter as below. 
    If the sensor is good, further diagnosis is required. There're many different codes for specific functional failures, which are NOT necessarily relevant to the sensor. Find out what the Code means before leaving any feedbacks.

     

    Items that have been installed, altered or contaminated are non-returnable.

    1. ONLY a defective sensor after tested by a voltmeter is applied to manufacturer warranty.
    2. 20% restocking fee is required if buyer bought wrong items due to not paying attention to fitment information and ask for return.

     

    The Price, Quality & Functionality of the O2 Sensor is fully covered under our warranty & return policy. However, refund for any labor cost, expense in a dealer shop or damage due to wrong installation is NOT covered.

    Item Specifics
    Country of Origin :United States
    Brand :WFLNHB
    Fitment Type :Direct Replacement
    Warranty :Yes
    Manufacturer Part Number :CB991905S00
    Number of Pieces :4
    Interchange Part Number :ASG823, A13441, AES20194, A234-4162, A234-4169
    Other Part Number :A-234-4161, A-SG1838, A-13095, A-ES20072
    Other Part Number 2 :AA8946534120, AA8946534130, AA8946534140, AA8946534150
    Modified Item :No
    Universal Or Specific Fit :Specific
    Thread Size :M18
    Wires :4
    Hex Size :7/8 in
    Housing Material :Metal
    Technology :Narrow-band
    Custom Bundle :Yes
    Position :Upstream, Downstream
    Attachment Method :Screw-On
    Terminal Type :Blade
    Heated :Yes
    Automotive Color / Finish :Steel
    Placement on Vehicle :Before After Catalytic Converter
    Bundle Description :Include 4 Piece Oxygen Sensor



    All rights reserved.



    On Apr 3, 2026 at 23:37:07 PDT, seller added the following information: