3M 6800 FULL FACE MASK Reusable Respirator Facepiece
 With 1 Pair Of 3M 2097 P100 Particulate Filters, Size: MEDIUM

3M 6800: 

This full facepiece reusable respirator offers lightweight comfort and ease of use. Combine with appropriate 3M™ particulate filters or cartridges to help provide respiratory protection against particulates and/or a variety of gases and vapors. Reliable, convenient, compatible respiratory protection. The 3M™ Full Facepiece Reusable Respirator 6000 Series offers versatility for many envrionments and applications and helps provide respiratory protection against a wide variety of gases and vapors when used with approved catridges and filters. When properly fitted and used with approved 3M™ Cartridges and Filters, helps provide respiratory protection from a variety of gases, vapors and particulate hazards at concentrations up to 10 times the Permissible Exposure Limit (PEL). Not for use in environments that are immediately dangerous to life or health (IDLH).

KIT INCLUDES: 


From the manufacturer

Helping You Wear It Right (always read and follow user instructions)

respirator mask, dust, lead, tear gas

respirator mask, dust, lead, mold, asbestos, tear gas

respirator mask, dust, lead, mold, asbestos, tear gas

respirator mask, dust, lead, mold, asbestos, tear gas

Step 1

Fully loosen all four head straps. Pull hair back with one hand. Bring facepiece up to face with other hand.

Step 2

While holding the facepiece in place, pull the straps over your head.

Step 3

Tighten the two bottom straps and then tighten the two top straps.

Step 4

Make sure the back of the harness is centered on the back of the head.

Perform a User Seal Check (always read and follow user instructions)

respirator mask, lead, asbestos, mold, tear gas

respirator mask, lead, asbestos, mold, tear gas

respirator mask, lead, asbestos, mold, tear gas

Positive Pressure User Seal Check

Place the palm of your hand over the opening in the exhalation valve cover and exhale gently. If facepiece bulges slightly and no air leaks are detected between the face and the facepiece, a proper seal has been obtained. If faceseal air leakage is detected, reposition the respirator on your face and/or readjust the tension of the straps to eliminate leakage and recheck seal. If you cannot achieve a proper seal, DO NOT enter the contaminated area. See your supervisor.

Negative Pressure User Seal Check Using Particulate Filters

Place your thumbs onto the center portion of the filters, restricting airflow through filters and inhale gently. If you feel facepiece collapse slightly and pull closer to your face with no leaks between the face and the facepiece, a proper seal has been obtained. If faceseal air leakage is detected, reposition the respirator on your face and/or readjust the tension of the straps to eliminate leakage and recheck seal. If you cannot achieve a proper seal, DO NOT enter the contaminated area. See your supervisor.

Negative Pressure User Seal Check Using Cartridges

Place palms of hands to cover face of cartridge or open area of 3M Filter Retainer 501 and inhale gently. If you feel facepiece collapse slightly and pull closer to your face with no leaks between the face and facepiece, a proper seal has been obtained. If faceseal air leakage is detected, reposition the respirator on your face and/or readjust the tension of the straps to eliminate leakage and recheck seal. If you cannot achieve a proper seal, DO NOT enter the contaminated area. See your supervisor.