| Instruction
|
||||||||||||
| Method of use
1. Plug in the power plug, turn on the power switch on the inverter, and use the speed control knob to select the appropriate speed. 2. The flow of materials and the power of the motor speed may resonate at a certain point. Please change the motor speed to avoid resonance. 3. After the stirring rod is installed, it must be rotated by hand, paying attention to whether the concentricity is good. If the concentricity is not good, loosen the heavy clamp, turn on the power after the clamp is correct, and gradually adjust from slow to fast. 4. Using the stirring rod regulator, the stirring leaf can be up and down 5cm as needed. 5. If you find that the sealing performance of the kettle has decreased, please check the rotating bearing in the agitator sleeve. 6. The interlayer on the glass kettle is connected to an external circulation port. Hot oil can be used for heating reaction, and cooling liquid can be used for low-temperature reaction. If steam heating is used, it should not exceed 0.5K-1K. (Try not to use pressure steam for heating). 7. When testing at low temperature, the discharge valve at the bottom will be frosted. When using the valve, it must be partially defrosted to prevent the glass from being broken. 8. If there are particulate objects in the solution during use, there may be leftovers on the PTFE piston of the valve during discharging. The air tightness will be affected when it is used again. Be sure to clean it after discharging each time and use it again.
|
||||||||||||
| Maintenance instructions
1.Check the instrument carefully before use. Whether the glass bottle is damaged and whether the interfaces are consistent. Be careful to handle it gently. 2. Wipe each interface with a soft cloth (can be replaced by a napkin), and then apply a little vacuum grease. (Vacuum grease must be covered after use to prevent dust and sand from entering.) 3. Each interface should not be tightened too tightly, and should be loosened regularly to avoid long-term locking and causing the connector to seize. 4. Turn on the power switch first, and then let the machine run from slow to fast. When shutting down, keep the machine in a stopped state, and then turn off the switch. 5. PTFE switches everywhere can't be tightened with excessive force, it is easy to damage the glass. 6. After each use, you must use a soft cloth to wipe off all kinds of oil stains, stains, and solvent remaining on the surface of the machine to keep it clean. 7. Loosen the PTFE switches after the machine stops, and the PTFE piston will be deformed if it is in the working state for a long time. 8. Clean the sealing ring regularly by removing the sealing ring, checking whether there is dirt on the shaft, wiping it with a soft cloth, then applying a little vacuum grease and reinstalling it to keep the shaft and the sealing ring smooth. 9. The electrical parts must not be exposed to water, and it is strictly forbidden to get wet. 10. When doing any repairs or inspections on the machine, be sure to cut off the power and water source first. |
||||||||||||
Parameter
|
||||||||||||
| Display | ||||||||||||
![]() |
||||||||||||
![]() |
||||||||||||
![]() |
||||||||||||
![]() |
||||||||||||
Item Included
|
||||||||||||
|
Shipping & Handling Details |
|
Default Shipping Cost or Free Shipping Information: Handling Time: Shipping is usually made in 1-3 business days after payments cleared. Orders are processed from Monday-Friday; Not on the weekends & public holidays. Sales tax / Customs duties: Any sales taxes or Customs duties are not included. If came out, they must be undertaken by the buyer. Sales Tax of 8% will be applied for orders shipped within the state of California. Damage In Shipping: Email or call us First! We will work with you to get the case resolved in the fastest method. |
|
Return / Refund |
|
If you are not 100% happy with your purchase, please contact Us. Please don't directly opened a request or case without informing us, or else, we will do some discounts on the warranty and other sales-services later on. Hope for your understanding. Returns & Exchanges ▲ All returns must be made within 14 days of delivery date. Items must be in new, unused condition, with all original materials included with the shipment. A partial refund may be applied for opened or damaged items, depending on the condition. Defective & Damaged Products |
|
Payment |
|
eCheck Issues: Payments via eCheck do not clear immediately. Usually you will wait 5-7 days after checkout for it to clear. Then we will arrange shipments for you.
|
|
Warranty & Feedback |
| ▲ 6 months' warranty for the machines, not for the consumables. We stand behind our products all the item, so even if your warranty period has expired, you can still seek for service or technical support from us with low cost. ▲ Any warranty shipping cost to us is responsible by buyer. ▲ Any shipping cost to buyer is responsible by the seller. ▲ We committee to the customer satisfaction and want to bring you the best purchase experience. If there is any problems, please contact us ASAP. If not, please leave us a positive feedback as it's very important for us. Thanks very much. |