Parameter:
Powe:750W/1500W/2200W/3000W
Input power:
Single-phase AC200V-240V 50Hz/60Hz /
Three-phase AC 200V-240V 50Hz/60Hz /
Three-phase AC 340V-440V 50Hz/60H
R.S.T: 380V models are connected to R, S, T, while 220V models are connected to R, S or R, T (determined by terminal labels)
U.V.W: Converter output, to connect the motor
P+.PR: Connector for braking resistor.
PE: Ground terminal
Please refer to the product page description for product parameters. If you need more detailed parameters, please contact us. Thank you.
Operation method:
1、Set the run command mode of frequency
The run command mode of frequency converter is set by parameter F0.02: There are two start-stop modes: panel control start-stop mode and terminal control start-stop mode:
(1) Panel control start-stop mode: (Factory setting for panel start-stop is F0.02=0) To use the panel control start-stop frequency converter, press the green button on the panel to start, The red button to stop. The converter starts with forward run by default, and the forward or reverse run needs to be set through the input terminal X1-X5 (the reverse setting is 4).
(2) Terminal control start-stop mode: (Factory setting for terminal start-stop is F0.02=1)
2、Selection of frequency setting mode of
The frequency setting mode of the converter is set by parameter F0.03. When F0.03=4, the running frequency is set by potentiometer; When F0.03=2, the running frequency is input by AVI (0-10V potentiometer can be connected externally); When F0.03=3, the running frequency is input by ACI (4-20mA); When F0.03=1, it is controlled by the external terminal (the switching value is set to be increasing/decreasing frequency).
Safety Precautions:
1. Before wiring, please check whether the input power is off.
2. The wiring should be carried out by professional electricians.
3. The grounding terminal must be grounded.
4. After the completing the emergency stop circuit wiring, please check whetherthe emergency stop action is effective.
5. Do not connect the output line of the frequency converter to the housing. Do not short circuit the output line.
6. Please confirm whether the voltage of the AC main circuit power supply is consistent with the rated voltage of the converter.
7. Do not carry out voltage resistance test on the frequency converter.
8. Please connect the brake resistor according to the wiring diagram.
9. Do not connect the power cord to the output terminals U, V and W.
10. Do not connect the contactor to the output circuit.
11. Be sure to install the protective housing before powering on. Be sure to disconnect the power supply before removing the housing.
12. Do not place the frequency converter with reset retry function near the mechanical equipment. Because it will suddenly restart when the alarm stops.
13. It can alarm and reset only after confirming that the running signal is cut off. If it alarms and resets in the running signal state, the frequency converter may start suddenly.
14. Do not touch the terminal of frequency converter. There is high voltage on the terminal, which is very dangerous.
15. Do not change wiring and disassemble terminals during power-on.
16. The inspection and maintenance should be carried out after the main circuit
power supply is cut off.
17. Please do not modify the frequency converter without permission.
Packaging includes:
It depends on your choice!