Specification:

 

1. Product Overview
The PCF series 304 stainless steel pneumatic quick-connect fittings feature an all-stainless steel internal thread + pneumatic tube quick-connect integrated design, including specifications such as PCF6-01 (G1/8‘), PCF8-02 (G1/4’), PCF10-03 (G3/8"), etc. These connectors are specifically designed for corrosive environments, food and medical applications, and high-cleanliness scenarios, combining military-grade sealing performance with an exceptionally long service life.

2. Core Parameters
Item    Technical Specifications
Material    304 stainless steel (mirror-polished surface with Ra ≤ 0.8 μm)
Pressure Range    Vacuum to 1.6 MPa (burst pressure ≥5.0 MPa)  
Temperature Resistance    -40°C to +200°C (short-term 250°C)  
Compatible Tubing    PU/silicone
Connection Standard    Threaded end: G thread (ISO 228-1)  
Surface Treatment    Electrolytic Polishing (EP) or Passivation Treatment (optional)  
3. Core Advantages  
✅ Superior Corrosion Resistance: Passes 96-hour salt spray test (ASTM B117), resistant to acids, alkalis, and organic solvents  
✅ Zero Contamination: Mirror polishing (Ra ≤ 0.8 μm) eliminates bacterial residue, meeting GMP cleanroom standards
✅ Quick-release design: Patented dual-latch structure (Patent No. CN202320584U), insertion/removal force ≤ 30N
✅ High flow rate: Straight-through flow channel design (pressure drop < 0.015MPa@1.0MPa)

4. Selection Comparison Table
Model    Outer diameter of air tube    Thread specification    Torque value    Typical application
PCF6-01    6±0.1mm    G1/8"    10-12 Nm    Pharmaceutical equipment/laboratory reactors
PCF8-02    8±0.1mm    G1/4"    15-18 Nm    Food filling machines/bioreactors
PCF10-03    10±0.2mm    G3/8"    20-25 Nm    Chemical pipelines/semiconductor gas transport
5. Special Process Notes
Electropolishing: Reduces surface roughness and prevents particle adhesion (suitable for cleanrooms)

Online cleaning (CIP): Supports 135°C high-pressure steam sterilisation cycles

Anti-misinsertion design: Different specifications use colour-coded rings (6 mm blue/8 mm green/10 mm red)

6. Installation specifications
Threaded seal:

Tighten to the recommended torque value to avoid overloading and intergranular corrosion

Air Tube Connection:  

Must use a dedicated tube cutter (e.g., SMC TU series) to ensure perpendicularity of the cut  

Clean the tube end with isopropyl alcohol before insertion  

Verification Testing:  

Helium mass spectrometry leak detection (≤1×10⁻⁹ Pa·m³/s)  