Agilent 3458A 8.5 Digit Digital Multimeter
Industry-Leading Accuracy, Speed & Performance
The Agilent / Keysight 3458A is widely regarded as one of the most accurate and versatile digital multimeters ever produced. Designed for demanding applications in production testing, R&D laboratories, and calibration environments, the 3458A delivers exceptional measurement speed, precision, and long-term stability.
Capable of up to 100,000 readings per second, the 3458A dramatically improves test throughput while maintaining outstanding accuracy and resolution of up to 8.5 digits.
Whether used on the bench or integrated into automated systems, the 3458A provides reliable, repeatable measurements for even the most demanding applications.
Key Features
Exceptional Speed & Throughput
-
Up to 100,000 readings per second
-
Internal test setups greater than 340 per second
-
Programmable integration times from 500 ns to 1 second
-
Ideal for automated production testing and high-speed measurement systems
Outstanding Accuracy & Resolution
-
Up to 8.5 digits resolution
-
0.1 ppm DC voltage linearity
-
0.1 ppm DC voltage transfer accuracy
-
0.01 ppm RMS internal noise
-
Extremely stable voltage reference
Long-Term Reliability
-
Self-adjusting, self-verifying auto-calibration
-
Two-source calibration including AC
-
Designed for long-term stability and reduced downtime
-
Low cost of ownership
Front Panel Features
Easy-to-Use Controls
-
Direct access to DCV, ACV, resistance, current, frequency, and period measurements
-
Autoranging and manual ranging
-
Simple menu navigation keys
Flexible User Functions
-
Numeric keypad for fast parameter entry
-
User-defined setups via shifted function keys (F0–F9)
Premium Measurement Terminals
-
Gold-plated tellurium copper terminals for minimal thermal EMF
-
Supports 2-wire and 4-wire resistance measurements
-
DC/DC and AC/AC ratio inputs
Current Measurement Convenience
-
Easy-access fuse holder built into front terminal assembly
Enhanced Noise Rejection
-
Dedicated guard terminal and switch for superior common-mode noise rejection
Front / Rear Input Switching
-
Quickly select front or rear measurement terminals
Performance Specifications
DC Voltage Accuracy
-
0.6 ppm accuracy over 24 hours
Resistance Accuracy
-
2.2 ppm accuracy over 24 hours
AC Voltage Accuracy
-
100 ppm mid-band AC volts
Voltage Reference Stability
-
8 ppm/year standard
-
4 ppm/year optional
Advanced Digitizing & Waveform Capability
-
16 to 24-bit resolution
-
Sampling rates from 100,000 to 0.2 samples/sec
-
12 MHz bandwidth
-
Timing resolution to 10 ns
-
Less than 100 ps time jitter
Ideal Applications
-
Calibration Laboratories
-
Precision Electronics Testing
-
Aerospace & Defense
-
Semiconductor & Research Labs
-
Automated Test Systems (ATE)
-
Metrology Applications