| Brand | HoldPeak |
|---|
| MPN | HP-38A |
|---|
| Current Type | Universal |
|---|
| Display | Digital |
|---|
| Voltage Range | 12-690V |
|---|
HP-38A 12~690V Three Phase Sequence Rotation Indicator Tester hecker LED Alarm
Specification
Brand: Holdpeak
Model:HP-38A
Material: ABS
*LED Indication Voltage Test:
Voltage Range: 12-690V AC/DC
Nominal Voltage Europe: 12/24/50/120/230/400/690V
Tolerance(Threshold Voltage)Light on at more than: 7±5V(50V LED), 18±5V(24V LED), 37.5±5V(50V LED), 75%±5% of nominal voltage(120/230/400/690V LED)
*LCD Display Voltage Test:
Range/Resolution: 7-690V/1V(Auto-range)
Accuracy(23±5C): (3%+3) or 5V
Over Range Indication: All Voltage LED light up
Response Time: <1s at 90% of each voltage
*High Voltage Indication:
Voltage Range 50-690V AC/DC
*Phase Rotation Test:
System: Three-phase 4-Wire system AC
Frequency: 50Hz~60Hz
Phase Range: 120±5 degree
*Continuity Test:
Detection Range: 0-550KΩ(±2O0K)
Test Current: Approx. 1.5uA(battery 3V 0Q)
*Reference Condition:
Battery: 2 * 1 5V(IEC LR03 1 5Vx2)
Temperature: -10~55°C Operation, -20~6O°C(Storage No condensation)
Humidity: Max 85% RH
Altitude: up to 2000m
Operating Temperature: -10~55°C / 14~131°F
Operating Humidity: ≤85% RH
Storage Temperature: -20~60°C / -4~140°F
Storage Humidity: ≤85% RH
Power Supply: IEC LR03 1.5V *2( not included in packaged)
Item Size: Approx. 25 * 5.5 * 2cm / 9.84 * 2.17 * 0.79in
Precautions
1 Never take measurements on a circuit in which the electrical potential exceeds 690V.(When the measured voltage exceeds 690V, all the voltage LED displays will light up)
2 Do not attempt to take measurements in the presence of flammable gasses, as the use of the.
3 Never attempt to use the instrument if the surface of your hands are wet. (Do not use in rain.)
4 Keep your hands and fingers behind the barriers during measurements.
5 Never unlock and open the battery case during measurements.
6 Verify proper operation on a known source before taking action as a result of the indication.
7 Never attempt to make any measurement in any abnormal conditions, such as a broken case.or exposed metal parts are present on the instrument or test probes.
8 Do not make any modification to the instrument.
9 Take extreme caution when live circuit LED flashes or lights up.
10 Correct indication of LEDs is only guaranteed within a temperature range of -10℃ up to 55℃(<85%RH).instrument may cause sparking, which could lead to an explosion.
Package List:
1 * Voltage Tester with Test Probe
1 * User Manual
| Model |
HP-38A |
| Voltage Test |
| LCD Voltage Range |
12-690V AC/DC |
| Accuracy(23±5℃) |
±(3%+3) |
| Resolution |
1V |
| LED Voltage Range |
12-690V AC/DC |
| Tolerance(Threhold Voltage) |
Light on at more than |
| :7±5V(12V LED):18±5V(24V LED) |
| :37.5±5V(50V LED):75%±5% of norminal voltage |
| (120/230/400/690V LED) |
| High voltage indication(LED indicator) |
| Voltage Range |
50-690V AC/DC |
| Phase Range |
120±5 degree |
| Phase rotation test |
| Detection Range |
0-750kΩ |
| Test Current |
Approx. 1.5μA |
| IP Rating |
IP64 |