| Industrial Door Motor Roller Sub Sliding Up and Over Garage Door Machine 110V |
| PreAsion® |
|
| The side shaft type industrial door motor is a heavy-duty driving device for overhead doors and sectional doors. It adopts a shaft drive structure and is equipped with a control box, effectively achieving balanced collaboration with the torsional spring balancing system, substantially reducing the motor load and well ensuring the door stops at any position and runs smoothly. The side shaft type industrial door motor can be widely applied to workshops, logistics warehouses, cold chain centers and other scenarios. |
| Model | INDUS60 |
| Voltage | 110V 60Hz |
| Rated Power | 400W |
| Maximum Loading Door Area | 30m2 (35.8sq.yd) |
| Output Torque | 60N.m |
| No-load Continuous Running Time | 15min |
| Thermal Protection Temperature | 120˚C (248˚F) |
| Reduction Ratio | 1:58 |
| No-load Rotation Speed | 24r/min |
| Lubricating System | Oil-immersed type |
| Noise | ≤55dB |
| Manual Chain | 360˚ reverse chain |
| Maximum Limit Travel | Output shaft rotates for 20 rounds. |
| Output Shaft Diameter | Φ25.4mm (1in) |
| Environment Temperature | -20˚C~+45˚C (-68˚F~+113˚F) |
| Working System | S2-15min |
| Protection Class | IP54 |
| Net weight | 16.6kg (36.6LBs) |
|
|
|
1. The industrial door
operator should be installed and adjusted by professional
personnel. Otherwise, serious personal injury or property damage
may occur.
2.
Installation and wiring must be conducted in accordance with the
construction standards and electrical standards. The wire
diameter ≧ 1.5mm2, the power source must have reliable
grounding, the ground wire must be reliably connected to the
place labeled ground tab, the ground lead on the power line is
prohibited from being removed, and the front end of incoming
power line should be equipped with the electrical leakage
protector which is in line with national standards.
3. The industrial door
operator is only allowed to be installed on the well-balanced
door where the balance spring has been installed, otherwise the
machine may be damaged due to overload.
4. The door should be flexible
and run without stagnation; the mechanical stop block or
buffering booster must be installed at the lead rail end of the
door to prevent the door from sliding out.
5. The control box should be
installed on the wall or column where the operation of the door
can be observed and the height of the control box above the
ground is 1.4 meters, so as to prevent children from
inadvertently touching. While keeping the remote controllers,
prohibit children from touching or playing just in case of
danger. Do not use the remote controllers when you cannot see
the operation of door.
6. Before repairing and moving
the door motor and control box, please cut off the power supply,
and make sure that the door has been locked and the risk of
falling due to the self weight does not exist.
7. Pedestrians and vehicles
are prohibited from going through or stay below the running
door.
8. The hand-pulled chain on
the machine is prohibited from being pulled during the operation
of door machine, so as to to prevent the machine from damage.
9. To ensure the safety of
pedestrians and vehicles, please install the infrared protection
device and airbag protection device.
10. Relevant safety protection
devices and the operation of the door should be checked
frequently to ensure the safety and stability of the door.
|
|
1. Check the door.
After the door is installed, adjust the torsion spring, ensure that manually opening or closing the door should be flexible and run without stagnation, observe the direction of rotation of the rope sheave which should be consistent with the direction of opening and closing of industrial door operator. 2. Determine the installation
position
Consider the boundary dimension and installation direction of the door machine, determine the position of the mounting bracket, mark the mounting hole position, drill the screw hole and fix the mounting bracket. (The mounting bracket can be fixed inside and outside the door machine, it is recommended to install it on the inner side for convenient disassembly of the door machine). 3. Try to install the industrial
door operator
Install a fixing sleeve on the door shaft in advance, and insert the industrial door operator into the door shaft. 4. Pre-fix the industrial door
operator.
Fix the industrial door operator on the mounting bracket, and do not tighten the bolts. 5. Align the direction of key
slot
Pull the hand-pulled chain up and down to rotate the output shaft of the industrial door operator until the key slot of the output shaft is fully aligned with the key slot of the door shaft. (Note: When releasing the hand-pulled chain, make sure that the hand-pulled chain has been reset successfully.) 6. Mount the flat key and fixing
sleeves.
Mount the flat key, keep two fixing sleeves close to the two ends of the output shaft, and fasten the two M8 head screws in the key slot of the door shaft to prevent the flat key from loosening and falling off. 7. Tighten the screws, and
prepare wiring and debugging.
Tighten all screws. 8. Conduct wiring operation.
Pull the cable through the waterproof connector on the door machine, and connect it with the wiring terminal inside the industrial door operator according to the instruction of cable markers. |
|
|
|
|
|
Default Shipping Cost or Free Shipping Information:
If you are not 100% happy with your purchase, please contact Us. Please don't directly opened a request or case without informing us, or else, we will do some discounts on the warranty and other sales-services later on. Hope for your understanding.
Returns & Exchanges
eCheck Issues: Payments via eCheck do not clear immediately. Usually you will wait 5-7 days after checkout for it to clear. Then we will arrange shipments for you.