ANCEL Refrigeration Digital Manifold Gauge HVAC Diagnostic Air Conditioning Tool
ANCEL AC3000 Introduction
ANCEL AC3000 digital manifold is a professisional instrument for installation, testing and maintenance of refrigeration equipment suchas air conditioners and cold stores. It combines 2-way pressure test, dual temperature measurements ( with optionaldual temperature probes ), a 32-bit digitalprocessor and a large LCD in one easy-to-useinstrument with the following main functions.
1.Pressure and Saturation Temperature
2.Vacuum Operation
3.Pressure Leak Test with recording
4.Direct T1 T2 Temperature, Real-timeSuperheat and Subcooling Simultaneously Display with Optional Two Clamp-onTemperature Probes
5.89 Refrigerant Profiles Stored in The Instrument
6.Automatic Multi-unit Pressure Conversion
7.Automatic Temperature ℃/℉ Conversion
It is the right one you have to do the job right.
 

Pressure Measuring
1. Turn off the blue valve and red valve.
2. Turn on the instrument. Then verify that LCD displays the status of the pressure test.If not,press the function button to switch it.
3. When the instrument is turned on, theremay be 10 digits in the high and low pressure display area. At this time, press the zero button long until it returns to zero.
4. Press R+/ R- buttons , Unit button and ℃/℉ button to select tested refrigerant and reading display respectively.
5. If the clamp-on temperature probes havebeen connected to the instrument, the real-time temperature will be displayed.If not, no display of it.
6. Connect the instrument to the refrigeration system according to thechart below.
7. Turn on the refrigerant valve and gently press the pressure release valve to vent the air in the connecting hose.
8. When the refrigeration system stops, turnon the high pressure valve (red valve) and fill with a certain amount of refrigerant and then shut the valve quickly.
9. Run the refrigeration system, turn on the low pressure valve (blue valve), and fill with the refrigerant into the refrigeration system.
10. After the filling is completed, shut the low pressure valve (blue valve) and refrigerant valve. Let the refrigeration system running.
11. Shut down the refrigeration system,make sure all valves are turned off , then disconnect the instrument between refrigeration system and source. Do not remove the high pressure valve connection until the pressure drops to the safe point. Then turn off the instrument.
 
Note:
The filling operation of different equipment or refrigerants may vary. Please read carefully the relevant specific operation requirements for filling operation,so as to avoid damage to user or equipment caused by improper operation! ! !
1.The instrument can display the corresponding Evaporation Temperature(EV) and Condensation Temperature (CO) during the refrigerant pressure test
2.If the clamp-on temperature probes are connected to the instrument, LCD will display the real-time temperature in the spot T1 Sensor and T2 Sensor.Please make sure clamp-on temperature probes are connected as step 6 and contacted fully to the refrigeration pipes.
3.The instrument can calculate the SH-Superheat and SC - Subcooling as long as the tested refrigerant ispreset and clamp-on temperature probes are connected well.

Vacuum Operation
1. Turn off the blue valve and red valve.
2. Power on the instrument. Then make surethe LCD displays vacuum test status.If not, press the Function button to switch it.
3. When the instrument is turned on, there may be 10 digits in the high and low pressure display area. At this time, press the zero button long until it returns to zero
4. Press the unit button to adjust the reading unit.
5. Connect the instrument to the refrigeration system.(Connected clamp-on temperature probes will not affect the operation.)
6. Turn on the blue valve and red valve, andstart the vacuum pump.
7. After the vacuum operation is completed,turn off the blue valve and red valve, then shut the vacuum pump. At this time,pressure leak test mode can be used to check leakage in the system ( Please refer to Pressure Leak Test).
 

Pressure Leak Test
1. The instrument is powered on with the blue and red valves turned off.
2. Press the Function button to pressure leak test mode.The current pressure value is displayed at lower rightcorner of LCD.
3.Press the Run/Stop button to start the leak test
At this time, the lower left corner records the initial pressure value; the lower right corner displays the instantaneous pressure value; the "P" display area shows the difference between the initial pressure value and the instantaneous pressure value.
The time display shows how long the leak test will take, in hour : minute (HH:MM)format. All pressure units on the screen are the same. You can switch between the different pressure units by pressing the Unit button.
 

89 Kids of Refrigeant Database:
Built-in 89 kinds of refrigerant NIST: According to AmericanNIST standard:
R11 R113 R114 R115 R116 R12 R123 R124 R125 R1270
R13 R134A R14 R141B R142B R143A R152A R170 R21 R218
R22 R227EA R23 R236EA R245CA R245FA R290 R32 R401A R401B
R401C R402A R402B R403A R403B R404A R405A R406A R407A R407B
R407C R407D R407E R408A R409A R409B R41 R410A R410B R411A
R411B R412A R413A R414A R414B R415A R415B R416A R417A R418A
R419A R420A R421A R421B R422A R422B R422C R422D R423A R424A
R425A R426A R427A R428A R50 R500 R501 R502 R503 R504
R507A R508A R507B R509A R600 R600A R707 R7441C02) R1234
 

Wide Range of applications
Automotive Air Conditioning
Household Air Conditioning
Cold Storage
Refrigeration Equipment
 

Specifications:
Pressure test: gauge pressure
Pressure test unit: Kpa; Mpa; bar; inHg; PSI.
Pressure test range: 0 Kpa – 6000 Kpa
Pressure test resolution: 1 Kpa
Pressure test accuracy: +/- 0.5 %(FS)+ 5dgt
Pressure overload limit: 10000 Kpa (10 Mpa; 100 bar;)
Vacuum test: relative vacuum
Vacuum test unit: Kpa; Mpa; bar; inHg; PSI.
Vacuum test range: -101 Kpa – 0 Kpa
Vacuum test resolution: 1 Kpa
Temperature test unit: °C (Celsius), °F (Fahrenheit)
Temperature test range: -40°C–150°C (-40°F–302°F)
Temperature test resolution:
0.1°C (-40°C–99.9°C), 1°C (100°C–150°C)
0.1°F (-40°F–99.9°F), 1°F (100°F–302°F)
Temperature test accuracy: +/- 0.5 °C + 2dgt +/- 0.9 °F + 2dgt
Built-in 89 kinds of refrigerant NIST: According to AmericanNIST standard
Power Supplies: 4 X 1.5V (SIZE.AA / LR6) Battery not include

Ancel AC3000 refrgerantion Digital Manifold Gauge
0.Clamp on temperature probe socket
1,Lcd display
2,Function Button
3,Run/Stop button
4,Zero button
5,R+/R-Refrigerant Type Selection Buttons
6,Backlit button
7,Unit Button
8,C/F Button
9,Power button
10,High Pressure Button
11,Refrigerant Obezervation Window
12,Pressure release valve
13,Refrigerant inlet/vacuum Pump inlet
14,Low Pressure Valve
15,1/4 inch high pressure inlet
 

Packing List:
1 x AC3000 Manifold Digital Meter
1 x Paper Box
1 x User Manual
 

Maintenance
1. Clean the exterior with a damp cloth. Do not use harsh solvents.
2. Keep screw connections clean and free of grease, clean with a moist cloth as required.
3. Carefully blow out oil residues in valve block using compressed air.
4. Replace the batteries when low battery power indication lights on in LCD.

Troubleshooting
Low battery power supply
The instruments has low power sign.When it is displayed , it means the battery power is insufficient. At this time, the battery should be replaced as required in order to avoid affecting normal use.
Damaged refrigerant hose orvalve stem
Please check the pipe connections and hoses before testing. If you find any damage,please replace them immediately to avoid improper use or accident.
Failure of refrigerant filling
There is a valve core in the refrigerant inlet of the refrigeration system. When connecting the instrument, pay attention the two terminals of the hoses. Connect one terminal with a core to the refrigeration system, while another terminal without acore to the instrument.

Potential leak points
1. Every hose terminal comes with a nylonpad that is limited a certain life of using.Over use or other situation will make itdefective, which result in leakage.
2. The instrument refrigerant inlet (the middle port of the instrument ) has a port with valve core , which is used to vent the air in the hoes after connecting the refrigerant to the instrument.
3. The port is equipped with a copper plug screw. It is required to tighten it every time before or after operation.
4. Check the refrigeration system's pipes and connectors

  • We accept Credit cards、Debit card、Apple Pay、Google Pay ect payment.
  • Please contact us first if you need to use another method to pay.
  • Payment should be made within 3 days after bidding ends, or we would cancel it for you.
  • Buyers should be responsible for any taxes.
  • Please include your special requests in eBay note if there is any.
 
  • Seller Processing Time:Items would be shipped out within 1 business day after cleared payment.
  • Carrier and Logistics:All Orders are Free shipping via Royal Mail (Logistics: Royal Mail Tracked 24/48). If you need express, extra postage price would be charged.
 
  • VAT Fee: The price has included a 20% VAT fee, which is charged by the EBAY platform, not by the seller.
  • Guarantee: 100% Genuine, 7 Days Free Exchange, 1 Month Free Return and Full Money Back Guarantee, Lifetime Free Technical Support.
  • Warranty: 12 months free repair for the devices.3 months for the accessories. Please contact us firstly when you need warranty service. Please contact us firstly when you need warranty service.
  • We are selling OBD Product, including OBDII Code Reader, Car Diagnostic Tool, Truck Diagnostic Tool, EVAP Smoke Machine, Car Power Probe,Battery Tester ect. The price is reasonable and we have top rated after-sales service.
  • Our main brand is ANCEL, and we also sell other brands product, such as FOXWELL, LAUNCH, THINKCAR, AUTOPHIX, etc
  • We have office and warehouse in UK, Australia and US to ensure fast shipment and after-sale service.
  • We have more than 100 employees devoting to customer satisfaction.

 
 
 
  • Our customer-oriented service strives for positive feedback with all 5 star selling ratings.
  • We automatically submit positive feedback to our buyers once the payment is cleared.
  • If anything about your transaction did not meet your expectations, PLEASE LET US KNOW AND GIVE US THE OPPORTUNITY TO MAKE THINGS RIGHT before you leave feedback or open any case.
  • We are 100% sure that we can solve any issues regarding your purchase.
  • We will reply within one business day. Business time: GMT8 (9:00-18:00) from Monday to Friday.


On 05-Jan-2026 at 07:06:15 GMT, seller added the following information:

Datacaciques