ANCEL AC3000 Introduction ANCEL AC3000 digital manifold is a professisional instrument for installation, testing and maintenance of refrigeration equipment suchas air conditioners and cold stores. It combines 2-way pressure test, dual temperature measurements ( with optionaldual temperature probes ), a 32-bit digitalprocessor and a large LCD in one easy-to-useinstrument with the following main functions. 1.Pressure and Saturation Temperature 2.Vacuum Operation 3.Pressure Leak Test with recording 4.Direct T1 T2 Temperature, Real-timeSuperheat and Subcooling Simultaneously Display with Optional Two Clamp-onTemperature Probes 5.89 Refrigerant Profiles Stored in The Instrument 6.Automatic Multi-unit Pressure Conversion 7.Automatic Temperature ℃/℉ Conversion It is the right one you have to do the job right. ![]() |
Pressure Measuring 1. Turn off the blue valve and red valve. 2. Turn on the instrument. Then verify that LCD displays the status of the pressure test.If not,press the function button to switch it. 3. When the instrument is turned on, theremay be 10 digits in the high and low pressure display area. At this time, press the zero button long until it returns to zero. 4. Press R+/ R- buttons , Unit button and ℃/℉ button to select tested refrigerant and reading display respectively. 5. If the clamp-on temperature probes havebeen connected to the instrument, the real-time temperature will be displayed.If not, no display of it. 6. Connect the instrument to the refrigeration system according to thechart below. 7. Turn on the refrigerant valve and gently press the pressure release valve to vent the air in the connecting hose. 8. When the refrigeration system stops, turnon the high pressure valve (red valve) and fill with a certain amount of refrigerant and then shut the valve quickly. 9. Run the refrigeration system, turn on the low pressure valve (blue valve), and fill with the refrigerant into the refrigeration system. 10. After the filling is completed, shut the low pressure valve (blue valve) and refrigerant valve. Let the refrigeration system running. 11. Shut down the refrigeration system,make sure all valves are turned off , then disconnect the instrument between refrigeration system and source. Do not remove the high pressure valve connection until the pressure drops to the safe point. Then turn off the instrument. ![]() ![]() Note: The filling operation of different equipment or refrigerants may vary. Please read carefully the relevant specific operation requirements for filling operation,so as to avoid damage to user or equipment caused by improper operation! ! ! 1.The instrument can display the corresponding Evaporation Temperature(EV) and Condensation Temperature (CO) during the refrigerant pressure test 2.If the clamp-on temperature probes are connected to the instrument, LCD will display the real-time temperature in the spot T1 Sensor and T2 Sensor.Please make sure clamp-on temperature probes are connected as step 6 and contacted fully to the refrigeration pipes. 3.The instrument can calculate the SH-Superheat and SC - Subcooling as long as the tested refrigerant ispreset and clamp-on temperature probes are connected well. |
Vacuum Operation 1. Turn off the blue valve and red valve. 2. Power on the instrument. Then make surethe LCD displays vacuum test status.If not, press the Function button to switch it. 3. When the instrument is turned on, there may be 10 digits in the high and low pressure display area. At this time, press the zero button long until it returns to zero 4. Press the unit button to adjust the reading unit. 5. Connect the instrument to the refrigeration system.(Connected clamp-on temperature probes will not affect the operation.) 6. Turn on the blue valve and red valve, andstart the vacuum pump. 7. After the vacuum operation is completed,turn off the blue valve and red valve, then shut the vacuum pump. At this time,pressure leak test mode can be used to check leakage in the system ( Please refer to Pressure Leak Test). ![]() ![]() |
Pressure Leak Test 1. The instrument is powered on with the blue and red valves turned off. 2. Press the Function button to pressure leak test mode.The current pressure value is displayed at lower rightcorner of LCD. 3.Press the Run/Stop button to start the leak test At this time, the lower left corner records the initial pressure value; the lower right corner displays the instantaneous pressure value; the "P" display area shows the difference between the initial pressure value and the instantaneous pressure value. The time display shows how long the leak test will take, in hour : minute (HH:MM)format. All pressure units on the screen are the same. You can switch between the different pressure units by pressing the Unit button. ![]() |
89 Kids of Refrigeant Database: Built-in 89 kinds of refrigerant NIST: According to AmericanNIST standard: R11 R113 R114 R115 R116 R12 R123 R124 R125 R1270 R13 R134A R14 R141B R142B R143A R152A R170 R21 R218 R22 R227EA R23 R236EA R245CA R245FA R290 R32 R401A R401B R401C R402A R402B R403A R403B R404A R405A R406A R407A R407B R407C R407D R407E R408A R409A R409B R41 R410A R410B R411A R411B R412A R413A R414A R414B R415A R415B R416A R417A R418A R419A R420A R421A R421B R422A R422B R422C R422D R423A R424A R425A R426A R427A R428A R50 R500 R501 R502 R503 R504 R507A R508A R507B R509A R600 R600A R707 R7441C02) R1234 ![]() |
Wide Range of applications ✔ Automotive Air Conditioning ✔ Household Air Conditioning ✔ Cold Storage ✔ Refrigeration Equipment ![]() |
Specifications: Pressure test: gauge pressure Pressure test unit: Kpa; Mpa; bar; inHg; PSI. Pressure test range: 0 Kpa – 6000 Kpa Pressure test resolution: 1 Kpa Pressure test accuracy: +/- 0.5 %(FS)+ 5dgt Pressure overload limit: 10000 Kpa (10 Mpa; 100 bar;) Vacuum test: relative vacuum Vacuum test unit: Kpa; Mpa; bar; inHg; PSI. Vacuum test range: -101 Kpa – 0 Kpa Vacuum test resolution: 1 Kpa Temperature test unit: °C (Celsius), °F (Fahrenheit) Temperature test range: -40°C–150°C (-40°F–302°F) Temperature test resolution: 0.1°C (-40°C–99.9°C), 1°C (100°C–150°C) 0.1°F (-40°F–99.9°F), 1°F (100°F–302°F) Temperature test accuracy: +/- 0.5 °C + 2dgt +/- 0.9 °F + 2dgt Built-in 89 kinds of refrigerant NIST: According to AmericanNIST standard Power Supplies: 4 X 1.5V (SIZE.AA / LR6) Battery not include |
Ancel AC3000 refrgerantion Digital Manifold Gauge 0.Clamp on temperature probe socket 1,Lcd display 2,Function Button 3,Run/Stop button 4,Zero button 5,R+/R-Refrigerant Type Selection Buttons 6,Backlit button 7,Unit Button 8,C/F Button 9,Power button 10,High Pressure Button 11,Refrigerant Obezervation Window 12,Pressure release valve 13,Refrigerant inlet/vacuum Pump inlet 14,Low Pressure Valve 15,1/4 inch high pressure inlet ![]() |
Packing List: 1 x AC3000 Manifold Digital Meter 1 x Paper Box 1 x User Manual ![]() |
Maintenance Troubleshooting Potential leak points |