| ANGLE MEASUREMENT |
Horizontal Accuracy Standard deviation based on DIN 18723
|
1” 0.3 mgon
|
Vertical Accuracy Standard deviation based on DIN 18723
|
1” 0.3 mgon
|
Angle Reading (least count) Standard mode Tracking mode
|
1” (0.3 mgon) 2” (0.6 mgon)
|
| Dual-axis compensator |
±6’ (±100 mgon) |
| DISTANCE MEASUREMENT ACCURACY |
Prism Mode Standard mode Tracking mode *1*
|
±(2 mm + 2 ppm) ±(0.0065 ft + 2 ppm) ±(4 mm + 2 ppm) ±(0.013 ft + 2 ppm)
|
| Synchronized angle and distance measurements |
Yes
|
| Position update rate |
Up to 20Hz |
DR Reflectorless Mode Standard mode Scanning mode
|
±(2 mm + 2 ppm) ±(0.0065 ft + 2 ppm) ±(4 mm + 2 ppm) ±(0.013 ft + 2 ppm)
|
| MEASUREMENT RANGE |
Prism Mode (under clear conditions *2* *3*) 1 prism 1 prism (long range mode)
|
2,500 m (8,202 ft) 5,500 m (18,044 ft)
|
DR Reflectorless Mode *4* Kodak Gray Card (18% reflective) Kodak Gray Card (90% reflective)
|
>600 m (1969 ft) >1300 m (4265 ft)
|
Servo system
|
MagDrive servo technology, integrated servo/angle sensor, electromagnetic direct drive
|
| Rotation speed |
115 degrees/sec (128 gon/sec) |
| Clamps and slow motions |
Servo-driven, endless fine adjustment |
| Positioning speed 180 degrees (200 gon) |
3.2 sec |
| TELESCOPE |
| Magnification |
30x
|
| Field of view |
2.6 m at 100 m (8.5 ft at 328 ft) |
| Shortest focusing distance |
1.5 m (4.92 ft) – infinity |
| Illuminated crosshair |
Variable (10 steps) |
| POWER SUPPLY |
Internal battery
|
Rechargeable Li-Ion battery 11.1 V, 4.4 Ah |
Operating time *5*
|
Approximately 6 hours on one internal battery |
WEIGHT
|
| Instrument with internal battery |
5.25 kg (11.57 lb) |
| ROBOTIC SPECIFICATIONS |
Range *2*
|
700 m (2,297 ft) |
| Shortest search distance |
0.2 m (0.65 ft) |
| ATS MODE FOR GRADE CONTROL |
| Range to target (MT900)*1* *2* *3* |
700 m (2,297 ft) |
| Search time (typical) *6* |
2-10 s |
| Search area |
360 degrees (400 gon) or defined horizontal and vertical search window
|
Maximum velocity of target Radial speed Axial speed
|
114°/s 6 m/s
|
Data output
|
Rate
|
20 Hz
|
Timing
|
± 1 ms
|
| Latency over radio |
40 ms
|
Synchronized measurement data
|
<1 ms |
| Number of Target ID channels |
16
|