The Sorensen MML-2 is a 4U, two-bay programmable DC electronic load mainframe designed for versatile bench-top or rack-mount environments. Each bay accepts a plug-in load module, providing up to 1.2 kW of total sink capacity when both bays are populated with 600 W modules. Front-panel push-button and keypad controls allow local setup and operation, while RS-232C comes standard for remote control; an optional IEEE-488.2 (GPIB) interface supports full SCPI-style command sets. Built-in self-test on power-up, remote sense inputs, and analog Go/No-Go status outputs ensure reliable, repeatable performance in engineering and manufacturing test applications.
MML-80V-120A-601 Module Specifications
- Power and Voltage
- Maximum power: 600 W
- Maximum voltage: 0–80 V DC
- Maximum current: 0–120 A
- Operating Modes
- Constant Current (CC), Constant Voltage (CV), Constant Resistance (CR)
- Programmable slew rates up to 5 A/μs
- Continuous or pulsed loading up to 20 kHz
- Short-circuit simulation with programmable duration
- Measurement and Control
- 15-bit A/D resolution for voltage and current readback
- Two current ranges (0–12 A and 0–120 A) selectable per channel
- Up to 10 programs and 10 sequences per program stored in module memory
- Synchronization across modules for parallel or multi-stage testing
- Protection Features
- Overcurrent (OCP), Overvoltage (OVP), Overpower (OPP)
- Overtemperature (OTP) and reverse-polarity protection
- Front-panel indicator LEDs and status registers report fault conditions
Firmware Revision 3.16 Details
Firmware 3.16 resides on the MML-80V-120A-601 module’s onboard microcontroller, managing control algorithms, calibration data, and communication protocols. Key enhancements in this revision include:
- Improved Transient Response
- Optimized slew-rate control reduces overshoot during rapid current steps
- Enhanced digital filtering for more stable CV/CC transitions
- Expanded Command Set and Diagnostics
- New SCPI query
:MEAS:CURR:OFFSET? to read internal zero-offset compensation - Extended status byte definitions for more granular fault reporting (e.g., OTP sub-codes)
- Calibration and Memory Management
- Non-volatile storage of per-module calibration coefficients with integrity checks
- Auto-recalibration routine accessible via
:CAL:START command
- Compatibility and Stability
- Ensures seamless operation with MML-2 mainframes at hardware revision B and later
- Resolved rare RS-232 framing errors under heavy command traffic