This Item Has A Current Calibration!
|
 |
|
|
AFL NOYES OFL 280-100 SingleMode 1310 / 1550nm FlexTester OTDR w/ VFL & Power Meter
Dynamic Range 1310 / 1550 nm : 34 / 32 dB
Power Meter: - 1310nm - 1490nm - 1550nm - 1625nm - 1650nm
Visual Fault Locator
Dual-wavelength testing at 1310 and 1550 nm is normally sufficient to certify point-to-point or FTTx (PON) networks and detect macro bends.
Includes Carrying Case & Accessories As Listed Above!
Working Condition: Excellent Condition: Refurbished Calibrated: Yes Warranty: 1 YEAR WARRANTY
OFL280-100 provides the best balance of functions and value for many users. Dual-wavelength testing at 1310 and 1550 nm is normally sufficient to certify point-to-point or FTTx (PON) networks and detect macro bends.
OFL280-100 Main Features:
- Compatible with all Noyes optical power meters and laser sources (OPM/OLS), including tone and wave ID features
- Compatible with Noyes optical fiber identifiers (OFI)
- Integrated hi-power optical power meter
- Integrated visual fault locator (red laser)
- 1310 nm – OTDR, PON OTDR, laser source (CW, wave ID, tone)
- 1550 nm – OTDR, PON OTDR, laser source (CW, wave ID, tone)
OFL280-100 Fiber Testing Applications:
Point-to-point cable construction and troubleshooting Fiber loss, splice/connection loss and reflectance, fault-location
FTTx PON construction Fiber loss, splitter loss and reflectance, splice or connection loss and reflectance, fault-location 1
FTTx customer fiber troubleshooting - dark fibers (hard faults) Locate cable cuts, open splices, and bad connections
Features
- Rugged, handheld and light weight
- Standard OTDR, PON OTDR, live fiber OTDR, and FTTx PON meter all from the same test port
- 0.8 m event dead zone, 3.5 m attenuation dead zone
- 34 dB dynamic range
- Fast Real Time OTDR mode
- Internal storage (>1000 OTDR traces in standard .SOR format)
- High-contrast display is clear and bright in any lighting condition, including direct sunlight
- Transfer test results to a PC via USB
- 10-hour operation, fast charge, Li-Ion battery
- Short power-on time (< 5 sec)
- Easy to use and learn
Applications
- PON OTDR - FTTx PON construction certification
- Live Fiber OTDR - FTTx service turn-up and troubleshooting
- Full Auto OTDR - Normal (point-to point) fiber cableconstruction testing and fault location
- Expert OTDR - Full function OTDR for experienced users
- Real Time OTDR - Fault location, splice verification, first connector checker
- End Locator - Quickly locate breaks or measure fiber length
- Optical Power Meter -Measure optical power or fiber loss
- Laser Source - Measure end-to-end loss or trace fibers using the tone feature and a Noyes OFI
- Visual Fault Locator - Red laser for fiber bend/break location and tracing
OTDR SPECIFICATIONS:
| Emitter Type |
Laser |
| Safety Class |
Class I FDA 21 CFR 1040.10 and 1040.11, IEC 60825-1: 2007-03 |
| Fiber Type |
Single-mode |
| Available Wavelengths |
1310/1550 nm |
Wavelength Tolerance
|
±20/±20 nm |
| Dynamic Range (SNR=1) |
34/32 dB |
| Event Dead Zone 1 |
0.8 m |
| Attenuation Dead Zone 2 |
3.5 m |
| Pulse Widths |
5, 10, 30, 100, 300 ns, 1, 3, 10 μs |
| Range Settings |
250 m to 240 km |
| Data Points |
Up to 30,000 |
| Data Point Spacing |
5.0 cm (range < 1.5 km), Range/30,000 (range > 1.5 km)
|
| Group Index of Refraction (GIR) |
1.4000 to 1.6000 |
| Distance Uncertainty (m) |
± (1 + 0.005% x distance + data point spacing) |
| Trace File Format |
Bellcore GR-196 V.1.1 |
| Trace File Storage Medium |
Internal memory (>1000 traces) |
| Data Transfer to PC |
USB cable |
| PON OTDR Modes |
FTTx - PON Construction, FTTx - In Service |
| Standard OTDR Modes |
Full Auto, Expert, Real Time |
Optical Power Meter
| Calibrated Wavelengths |
1310, 1490, 1550, 1625, 1650 nm |
| Detector Type |
InGaAs |
| Measurement Range |
+23 to – 50 dBm |
| Tone Detect Range |
+3 to -35 dBm |
| Wavelength ID Range |
+3 to -35 dBm |
Accuracy
|
± 0.25 dB |
| Resolution |
0.01 dB |
| Measurement Units |
dB, dBm or Watts |
laser Source
| Emitter Type |
Class I FDA 21 CFR 1040.10 and 1040.11, IEC 60825-1: 2007-03 |
| Fiber Type |
Single-mode |
| Available Wavelengths (nm) |
1310, 1550 |
| Wavelength Tolerance |
± 20 nm |
| Spectral Width (FWHM) |
2 nm (maximum) |
| Internal Modulation |
1 kHz, 2 kHz, CW |
| Wavelength ID (one, two, or three wavelengths) |
Compatible with Noyes Optical Power Meters and Light Sources |
| Output Power Stability |
0.25 dB |
| Output Power |
0 dBm |
Visual Fault Locator
| Emitter Type |
Laser |
| Safety Class |
Class II FDA 21 CFR 1040.10 and 1040.11, IEC 60825-1: 2007-03 |
| Wavelength |
650 nm |
| Output Power (nominal) |
0.8 mW into single-mode fiber |
General
| Size (in boot) |
19 x 11.2 x 4.7 cm (7.5 x 4.4 x 1.9 in) |
| Weight |
0.8 kg (1.7 lb) |
| Operational Temperature |
-10 to +50°C, 0 to 95% RH (non-condensing) |
| Storage Temperature |
-20 to +60°C, 0 to 95% RH (non-condensing) |
| Power |
Rechargeable Li-Ion or AC adapter |
| Battery Life |
10 hours, backlight ON, continuous operation |
| Display |
LCD, 320 x 240, 3.5 inch (89 mm), color, high-contrast transflective with backlight and AR coating |
For full Noyes OFL 280-100 product specifications, please click here: Noyes OFL 280-100
|
|
|
|
Please check our Huge Inventory with savings of up to 80% off of retail on Cat5/5e/6 LAN Cable Certifiers and Fiber Optic OTDR's, Fusion Splicers, CATV Meters, Fiber Optic Kits, Sources, Meters, Tools, Network Analyzers and much more. Here is a Link to our Ebay Test Equipment Store. All of our Test Equipment is backed with a Full Warranty and unbeatable customer support & service. Please don't hesitate to contact us for a Quote on Something you don't see in our inventory, sometimes we have items that may have not been listed or processed yet.
|
|
|
|
|
 |
|
 |
|
 |