Product description

Working mode:1.Momentary mode 2.Toggle mode3. Latching mode

Updated Version :DC 5–60V Motor Forward/Reverse Remote Control Switch

Latching: applied to rolling doors, telescopic doors, etc., can be used with a 3-key remote control, using the latching mode, 1 key controls forward rotation, another key controls reverse rotation, and the other key no need to be pairing code, press it to pause the device.

DC 12V 4 Channel Remote Control Switch

Toggle:One remote control button controls one relay.

The load end can be connected to 4 lamps or two motors.

A total of 7 working modes:

Momentary Mode

Toggle Mode

Latched Mode

2CH Momentary + 2CH Toggle

2CH Momentary + 2CH Latched

2CH Toggle + 2CH Latched

2CH Latched + 2CH Latched

AC 85~220V 2 Channel Remote Control Switch

Momentary: If work with a 2-button remote control, use the momentary mode, generally used to control switch, 2 channels can control 2 switches, but this situation is rare; It can also be used for motor equipment, rolling doors, curtains, etc. With a 2-button remote control, one button controls the forward rotation of the motor, and one button controls the reverse rotation of the motor. Release the remote control button and the device will stop.

DC 6V~30V 2 Channel Remote Control Switch

Latching: applied to rolling doors, telescopic doors, etc., can be used with a 3-key remote control, using the latching mode, 1 key controls forward rotation, another key controls reverse rotation, and the other key no need to be pairing code, press it to pause the device. The same goes for the remote control with 4 keys. The other 2 keys no need to be pairing code, press any of the keys will stop the device from working.

When you receive the product, please select one of the following modes for pairing before use.

Product Model Description(1202 2202 2402)

2CH Momentary Mode:

Step 1, press the button on the receiver board once

Step 2, press the A button, then the light of the receiver board will flash.

Step 3, Wait for the blinking to finish, then press another button B. The receiver board will blink again.

After pairing is complete, long press A button to control forward rotation and long press B button to control reverse rotation.

2CH Toggle mode:

Step 1, press the button on the receiver board twice.

Step 2, press the A button, then the light on the receiver board will blink.

Step 3, wait for the blinking to end, then press the B button once more, and the receiver board will blink again.

After the pairing is finished, short press the A button to control forward rotation and short press the B button to control reverse rotation. Short press the A/B button again, the motor will stop forward/reverse rotation.

2CH Latched mode:

Step 1, press the button on the receiver board three times.

Step 2, press the A button, then the light on the receiver board will blink.

Step 3, wait for the blinking to end, then press the B button once more, and the receiver board will blink again.

After the pairing is finished, short press A button to control forward rotation and short press B button to control reverse rotation. Press A+B button together, the motor stops rotating. You can also use other individual buttons to stop the rotation (except for the paired A and B buttons)

KR1202 + 2KT09(Updated:DC 5~60V 2CH)

Non-dry contact relay (M1 M2)

Contact Circuit Power Supply

Contact circuit is already energized

Wiring Method

Simpler wiring; ready for direct use

Flexibility

Low; constrained by internal circuit design

KR1204+2KT06(DC 12V 4-CH Remote Control Switch)

Dry contact relay (NO COM NC)

Contact Circuit Power Supply

Contact circuit is not energized; external power supply required.

Wiring Method

Requires additional wiring for power supply.

Flexibility

High, adaptable to various voltages/loads.

Dry contact relay (NO COM NC)

Dry contact relay (NO COM NC)

KR2202+4KT05(AC 85~220V 2-CH Remote Control Switch)

Dry contact relay (NO COM NC)

Contact Circuit Power Supply

Contact circuit is not energized; external power supply required.

Wiring Method

Requires additional wiring for power supply.

Flexibility

High, adaptable to various voltages/loads.

Dry contact relay (NO COM NC)

Dry contact relay (NO COM NC)

Dry contact relay (NO COM NC)

KR2402A+2KT06(DC 6V~30V 2-CH Remote Control Switch)

Dry contact relay (NO COM NC)

Contact Circuit Power Supply

Contact circuit is not energized; external power supply required.

Wiring Method

Requires additional wiring for power supply.

Flexibility

High, adaptable to various voltages/loads.

Dry contact relay (NO COM NC)

Dry contact relay (NO COM NC)

Dry contact relay (NO COM NC)