Features:
1. The autoclave strictly meets the standard of EN13060 and adopts European B standard with 3-time pre-vacuum preceding vacuum drying, having passed Vacuum test, Helix test and B&D test. Vacuum measurement reaches -0.8 bar and residual humidity is less than 0.2%.
2. It can be used for the sterilization of sanitary material (cotton and medical dressings, etc), other heat-resisting articles (plastic, etc) and miscellaneous wrapped or unwrapped medical instruments, whether solid or A-type hollow, whether multi-apertures or insert-pipes.
3. Fuzzily computer controlled, digital bright show. The interface is modularized panel for easy operation.
4. The alarm system of full waste water completely avoids the waste water circulation sterilizing.
5. With automatic alarm system of breakdowns, you can grasp the status of machine operation dynamically at any time.
6. Humanized design of water drain makes it more convenient to dry.
7. With built-in printer, the process of sterilization will be conveniently recorded.
Specifications:
Model: SUN18-II
Sterilization level: European Class B standard
Sterilizing temperature: 134℃/121℃
Voltage: AC220V/110V±10% 50/60Hz±lHz
Power: 1800W
Tank capacity: 18 litres
Inside dimensions: Ø249x355mm
Pw Size: 670×550×500mm
G.W.: 48KG
Technical specification:
1. Unifies the European B level standard, Has 3 times of pulsation types initial vacuum dry function, The vacuum degree mayreach-0.80bar,Is suitable is antiseptic in the clinic each kind of instrument disinfection, the instruments surplus humidity <0.1%,and the success solved the sterilizer not to be able to disinfect the plastic instrument difficult problem;
2. Entire computers controls, The pressure, the temperature digitization demonstration, enables you to operate handily;
3. Jet types steam generator, causes in the pot the temperature to be evener, disinfection deeper level.
4. Pots bodies by 2.5mm stainless steel disposable stretch;
5. Waste water tanks full water alarm system, Finished has let the waste water circulation disinfection the possibility, Causes the disinfection to have the significance;
6. Automatic failure detections report to the opilce, Enable you to grasp the loom as necessary dynamically;
7. Humanity bottom of the opt freeing port designs can dryly cause to be more convenient;
8.The high clear data printing, enable the antiseptic effect to arrive.
Packing List:
Autoclave: 1 piece
Water draining pipe: 1 piece
Device plate: 3pieces
Power cable: 1piece
Device shelf: 1piece
Hand-support plate: 1piece
Fuse: 2pieces
Operation Manual: 1piece
Measuring Cup: 1 piece