Long Description:

The MO165 manual motor starter magnetic only is a compact and powerful range for motor protection up to 45 kW (400 V) in width of 55 mm. The devices are used to manually switch on and off loads/motors and to protect them reliably and without the need for a fuse from short-circuits. The manual motor starter offers a rated service short-circuit breaking capacity up to 100 kA at 400 V AC. A combination together with overload relays or motor controllers allows the protection of motors. Further features are the built-in disconnect function, trip-free mechanism and a rotary handle with a clear switch position indication. The manual motor starters magnetic only are suitable for three- and single-phase applications. The handle is lockable to protect against unauthorized changes. Auxiliary contacts, signaling contacts, undervoltage releases, shunt trips, 3-phase bus bars and power in-feed blocks are available as accessory.


General Information:

Extended Product Type:

MO165-65

Product ID:

1SAM461000R1017

Catalog Description:

MO165-65 Manual Motor Starter Magnetic Only 65 A.

Technical


Rated Service Short-Circuit Breaking Capacity (Ics):

(230 V AC) 30 kA

(250 V DC) 3 Poles in Series 100 kA

(400 V AC) 30 kA

(440 V AC) 30 kA

(500 V AC) 20 kA

(690 V AC) 6 kA

Rated Ultimate Short-Circuit Breaking Capacity (Icu):

(230 V AC) 50 kA

(250 V DC) 100 kA

(400 V AC) 50 kA

(440 V AC) 45 kA

(500 V AC) 20 kA

(690 V AC) 8 kA

Rated Instantaneous Short-Circuit Current Setting (Ii):

975 A

Setting Range:

None

Rated Operational Power AC-3 (Pe):

(400 V) Three Phase 30 kW

Rated Operational Power AC-3e (Pe):

(400 V) Three Phase 30 kW

Rated Operational Voltage:

Main Circuit 690 V AC

Main Circuit 250 V DC

Rated Operational Current (Ie):

65 A

Rated Operational Current AC-3 (Ie):

65 A

Rated Operational Current AC-3e (Ie):

65 A

Rated Operational Current DC-5 (Ie):

65 A

Rated Frequency (f):

Main Circuit 50 Hz

Main Circuit 60 Hz

Operating Frequency (fsw):

0 ... 415 Hz

Rated Impulse Withstand Voltage (Uimp):

Main Circuit 8 kV

Rated Insulation Voltage (Ui):

1000 V

Power Loss:

8.03 W

Number of Poles:

3P

Conventional Free-air Thermal Current (Ith):

Main Circuit 65 A

Degree of Protection:

Housing IP20

Main Circuit Terminals IP10

Pollution Degree:

3

Electrical Durability:

25000 cycle

Mechanical Durability:

Nr. Operations 50000 cycle

Terminal Type:

Screw Terminals

Connecting Capacity Main Circuit:

Flexible with Ferrule 1/2x 1 ... 35 mm²

Flexible with Insulated Ferrule 1/2x 1 ... 35 mm²

Flexible 1/2x 1 ... 35 mm²

Rigid 1/2x 1 ... 4 mm²

Solid 1/2x 1 ... 4 mm²

Stranded 1/2x 1 ... 50 mm²

Tightening Torque:

Main Circuit 4 N·m

Wire Stripping Length:

Main Circuit 16 mm

Recommended Screw Driver:

Pozidriv 2

Mounting Position:

1 ... 6

Mounting on DIN Rail:

TH35-15 (35 x 15 mm Mounting Rail) acc. to IEC 60715

TH35-7.5 (35 x 7.5 mm Mounting Rail) acc. to IEC 60715

Minimum Mounting Distance:

Electrical Conductive Board, Horizontal - Up to 1000 V 1.5 mm

Electrical Conductive Board, Horizontal - Up to 400 V 0 mm

Electrical Conductive Board, Horizontal - Up to 690 V 1.5 mm

Electrical Conductive Board, Vertical 75 mm

Other Device Same Type, Horizontal 0 mm

Other Device Same Type, Vertical 150 mm

Actuator Type:

Rotary Handle

Contact Position Indication:

ON / OFF / TRIP

Standards:

CSA 22.2 No. 14

IEC/EN 60947-1

IEC/EN 60947-2

IEC/EN 60947-4-1

UL 60947-4-1

Remarks:

For overload protection of the motors, an appropriate thermal or electronic overload relays must be used