Purpose of each button:
Adjustment method for technician mode parameters:
Restore factory settings:
1. Error code(Fault handling)
Er03: Motor Hall or phase line error
Er04: Locked rotor protection
Er05: Hardware overcurrent protection
Er07: Serial communication timeout error
2. Technician mode parameter table:
P-02 Motor direction
P-04 Starting speed:200-800 rpm
P-05 Acceleration speed: 300-1350
P-07 Start switch
P-08 Brake function
P-10 Automatic running in
P-12 Acceleration time
P-14 Maximum current limit: 50-500