PROVA-2003 Average Sensing Digital Clamp Meter New

 

Introduction: 
 
DC/AC 2000A. 
 
Cable f 55mm, Bus Bar 72mm(D) x 22mm(W). 
 
True RMS (PROVA-2000). 
 
Average Sensing (PROVA-2003). 
 
DCA One Touch Zero. 
 
Auto Range A, V, W. 
 
Continuity. 
 
Max/Min/Hold. 
 
Relative Measurement. 
 

 

2.Specification:
DC Current (Autorange & Manual).

Range

Resolution

Accuracy

Overload Protection

400A

0.1A

+/- 1.5% +/- 3dgts

3000A

2500A

1A

+/- 1.5% +/- 3dgts

3000A

AC Voltage (Autorange & Manual, True RMS for PROVA 2000, Input Impedance 5M W for all ranges).

Range

Resolution

Accuracy

Overload Protection

4V

0.001V

+/- 1.5% +/- 5dgts

800VAC

40V

0.01V

+/- 1.5% +/- 5dgts

800VAC

400V

0.1V

+/- 1.5% +/- 5dgts

800VAC

600V

1V

+/- 1.5% +/- 5dgts

800VAC

Resistance ( Ω ) (Autorange & Manual, Open Circuit Voltage<=0.5V).

Range

Resolution

Accuracy

Overload Protection

400 Ω

0.1 Ω

+/- 1.5% +/- 3dgts

600VAC

4K Ω

1 Ω

+/- 1.5% +/- 3dgts

600VAC

40K Ω

10 Ω

+/- 1.5% +/- 3dgts

600VAC

400K Ω

100 Ω

+/- 1.5% +/- 3dgts

600VAC

4M Ω

1K Ω

+/- 1.5% +/- 3dgts

600VAC

40M Ω

10K Ω

+/- 1.5% +/- 3dgts

600VAC

Audible Continuity.

Range

Continuity Beeper

Open Circuit Voltage

Overload Protection

400 Ω

<=40 Ω (approx.)

<=0.5V

600VAC

Hz.

Range

Resolution

Accuracy

Sensitivity

Overload Protection

100-1000KHz

0.01-100Hz

+/- 0.5% +/- 2dgts

10mV/0.1V/1V

AC 600V

Diode Test.

Range

Resolution

Accuracy

Overload Protection

3V

0.001V

+/- 2.5% +/- 5dgts

600VAC

Current Analog Output (Overload Protection 600V).

Range

Output

Accuracy

Overload Protection

400A

1mV/A

+/- 2.5% +/- 0.5A

600VAC

2500A

1mV/A

+/- 2.5% +/- 5A

600VAC

DC Voltage (Autorange & Manual, Overload Protection 800VAC for all ranges).

Range

Resolution

Accuracy

Input Impedance

400mV

0.1mV

+/- 1.0% +/- 3 dgts

10M W

4V

0.001V

+/- 1.0% +/- 3 dgts

5M W

40V

0.01V

+/- 1.0% +/- 3 dgts

5M W

400V

0.1V

+/- 1.0% +/- 3 dgts

5M W

600V

1V

+/- 1.0% +/- 3 dgts

5M W

AC Current (Autorange & Manual, True RMS for PROVA 2000).

Range

Resolution

Accuracy

Overload Protection

50/60Hz

40-400Hz

400A

0.1A

+/- 1.5% +/- 5dgts

+/- 2.0% +/- 5dgts

3000A

2100A(0-1000)

1A

+/- 2.0% +/- 5dgts

+/- 2.5% +/- 5dgts

3000A

2100A(1000-2100)

1A

+/- 2.5% +/- 5dgts

+/- 3.0% +/- 5dgts

3000A

Gerenal Specification.

Jaw Opening

Cable f 55mm 
Bus Bar 65mm(D)x24mm(W)

Power Source

One 006P 9V or IEC 6F22 
or NEDA 1604 Battery

Operating Temperature

0 ℃ to 40 ℃ (32 ℉ to 104 ℉ )

Operating Humidity

Less than 80% RH

Dimensions

271mm(L)x112mm(W)x46mm(H) 
10.7"(L)x4.4"(W)x1.8"(H)

Weight

647g/22.8 oz (Battery included)

 
Tue, 07 Nov 2023 00:41:47 GMT 638349433078068652 CD141B8780F7142594ADD557621981AF