Specification:
1. Product Overview
The BUC series is a multifunctional control component that integrates a quick-connect air hose connector and a manual ball valve, offering five pipe diameter specifications: 4/6/8/10/12 mm. It provides dual functionality for quick air circuit connection and instant on/off control. Featuring a 304 stainless steel ball core and a copper alloy valve body, it is suitable for industrial pneumatic systems requiring frequent on/off operations.
2. Core Parameters
Specification Technical Specifications
Valve Body Material CW617N copper alloy (nickel-plated)/304 stainless steel (optional)
Ball Core Material 304 stainless steel (mirror-polished Ra ≤ 0.4 μm)
Sealing Material PTFE valve seat + NBR O-ring (Fluororubber optional)
Working Pressure 0.3–1.0 MPa (high-pressure type up to 2.5 MPa)
Temperature Range -20°C to +150°C
Flow Coefficient Cv 0.22 (4 mm) to 1.8 (12 mm)
Connection Method Inlet: G thread (optional NPT)
Exhaust end: Push-in quick connector (with safety lock)
Operating torque ≤1.5 Nm (with handle limit design)
3. Product Features
✅ One-button control:
90° rotation of the handle achieves fully open/fully closed (visualised open/closed status indicators)
Quick connector supports hot-swap (patented pressure relief structure)
✅ Zero leakage design:
Ball core and valve seat line contact sealing (leakage rate < 10⁻⁶ Pa·m³/s)
Dual sealing (axial O-ring + radial valve seat)
✅ Industrial-grade durability:
Ball core wear-resistant coating (HV ≥ 800)
Maintains sealing after 100,000 switching cycles
✅ Safety protection:
Anti-misoperation locking groove (lockable)
Static discharge terminal (ATEX version optional)
4. Selection comparison table
Model Hose outer diameter Threaded interface Cv value Applicable flow rate
BUC-4 4±0.1mm G1/8" 0.22 <50 L/min
BUC-6 6±0.2 mm G1/4" 0.45 50–150 L/min
BUC-8 8±0.2 mm G3/8" 0.78 150–300 L/min
BUC-10 10±0.3 mm G1/2" 1.25 300–600 L/min
BUC-12 12±0.3mm G3/4" 1.8 600-1000 L/min
5. Installation Guide
Threaded Connection:
Use PTFE tape or thread sealant (do not use on the PTFE valve seat side)
Use a wrench to secure the hexagonal part of the valve body to prevent distortion of the quick-connect structure
Air tube installation:
Ensure the air tube cut is smooth before insertion (recommended to use a dedicated tube cutter)
After hearing a ‘click’ sound, gently pull outward to confirm tightening
System testing:
Initial pressure hold: Test at 1.5 times the working pressure for 3 minutes
Switching test: Full-range operating torque ≤ rated value
● We accept multiple payment methods supported by the platform.
● We only accept your Ebay Address, Please Make sure it's 100% right.
● The items you ordered will be shipped out in 2 business days by Air Mail when your payment is clear.