Power Quality Analyser 6000A for Electric Power Metallurgy Railroad Departments
Introduction:
Main Function:
Features:
Specifications:
|
Power Supply |
Rechargeable lithium battery 7.4V, external charger |
|
Battery Indicator |
Battery symbol shows power energy. When the voltage is too low, automatic shutdown |
|
Working Current |
About 490 mA |
|
Instrument Dimension |
240mmX170mmX68 mm |
|
Display Mode |
5inch touch colorful screen |
|
Current |
Current clamp: 10A~6000A |
|
Clamp Current Sensor CT Size |
Φ200mm |
|
Frequency |
40Hz~70Hz. |
|
Harmonic |
Yes, 2~51 orders |
|
Total Harmonic Distortion |
Yes, 2~51orders, each phase |
|
Three-phases Unbalance |
Yes. |
|
Communication Interface |
USB |
|
Language |
Switch between Chinese and English |
|
Automatic Shutdown |
In recording mode, the instrument will not automatic shutdown |
|
When not in recording mode, can set the automatic shoutdown time after 15minutes,30minutes,60minutes according to request |
|
|
Automatic Shutdown |
In the alarm mode/trend chart record mode/transient capture mode (waiting or in progressing), the instrument will not automatic shutdown |
|
In other test mode, within 15 minutes without keystrokes operation, automatic shutdown after prompt 1 minute. |
|
|
Weight |
Host: 900g (with battery). |
|
Clamp current sensor: 510gX4 |
|
|
Test lines: 400g; |
|
|
Total weight: about 8kg (with all accessories). |
|
|
Memory Card |
4G(expandable up to 32G) |
|
Voltage Test Line Length |
3m |
|
Current Sensor Line Length |
2m |
|
Working Temperature |
-10°C~40°C; below 80%Rh. |
|
Storage Temperature |
-10°C~60°C; below 70%Rh. |
|
Input Impedance |
Input impedance of test voltage: 1MΩ. |
|
Withstand Voltage |
Withstand 3700V/50Hz sinusoidal AC voltage for 1 minute between instrument wiring and housing. |
|
Insulation |
Between instrument wiring and shell ≥10MΩ. |
|
Structure |
Double insulation, with insulation vibration-proof sheath. |
|
Suitable Safe Standard |
IEC 61010 Cat III 1000V /CAT IV 600V , IEC61010-031, IEC61326, Pollution degree 2 |
|
Measurement |
Range |
Display Resolution |
The Max Error In Reference Range |
|
Frequency |
40Hz~ 70Hz |
0.001Hz |
±(0.01)Hz |
|
Phase Voltage True RMS |
2V~ 600V |
Min resolution 0.001V |
±(0.5%rdg) |
|
Current True RMS |
10mA~ 6000A |
Min resolution 0.001A |
±(0.5%rgt) |
|
Active Power |
0.0000W~ 3600kW |
Min resolution 0.001W |
±(1%+3dgt)
Cosφ≥0.8 |
|
±(1.5%+10dgt)
0.2≤Cosφ<0.8 |
|||
|
Reactive Power |
0.000VAR~3600kVAR |
Min resolution 0.001VAR |
±(1%+3dgt)
Sinφ≥0.5 |
|
±(1.5%+10dgt)
0.2≤Sinφ<0.5 |
|||
|
Apparent Power |
0.000VA~9999.9kVA |
Min resolution 0.001VA |
±(1%+3dgt) |
|
Power Factor |
-1.000~ 1.000 |
0.001 |
±(1.5%+3dgt)
Cosφ≥0.5 |
|
±(1.5%+10dgt)
0.2≤Cosφ<0.5 |
|||
|
Phase Angle |
-179°~ 180° |
0.001° |
±(2°) |
|
Voltage Harmonic Ratio
2-51 orders (Vrms>50V) |
0.0%~ 99.9% |
0.001% |
(2~20orders)±(1%+5dgt)
(21~30orders)±(1%+10dgt)
(31~51orders)±(1%+15dgt) |
|
Voltage Harmonic Angled
(Vrms>50V) |
-179°~ 180° |
0.001° |
±(3°) harmonics for 2 - 25 orders |
|
±(10°) harmonics for 26 - 50 times |
|||
|
Current Harmonic Ratio
2-51 orders
(Arms>Irange/100) |
0.0%~99.9% |
0.001% |
(2~20orders) ±(1%rdg+5dgt)
(21~30orders) ±(1%rdg+10dgt)
(31~51orders) ±(1rdg%+15dgt) |
|
Current Harmonic Angle
(Arms>Irange/100) |
-179°~180° |
0.001° |
±(3°) harmonics for 2 - 25 orders
±(10°) harmonics for 26 - 51 orders |
|
Total Harmonic Ratio
(THD or THD-F)≤50 |
0.0%~ 99.9% |
0.001% |
±(1%rdg+10dgt) |
|
Distortion Factor
(DF or THD-R)≤50 |
0.0%~ 99.9% |
0.001% |
±(1%rdg+10dgt) |
|
Three-phases Unbalance |
0.0%~ 100% |
0.01% |
±(1%) |
|
Item |
Accessories |
Qty |
|
1 |
Host |
1PCS |
|
2 |
Clamp Current Sensor |
4PCS |
|
3 |
Pen Probe Test line(Each 1PCS of yellow,green, red and black, length 3m) |
4PCS |
|
4 |
Alligator Clip |
4PCS |
|
5 |
Power Adaptor(DC 12V) |
1PCS |
|
6 |
USB Data Cable |
1PCS |
|
7 |
4G Memory Card |
1PCS |
|
8 |
Manual, Warranty Card, Qualification Card |
1SET |