Pack contains one BENDER CC612 EV Charge Controller CC612-2M4PR B94060013 and one W15BS-03 MESSSTROMWANDLERSmart Grid capable via OCPP communication protocol Compact design, only 22.6 mm wide Supports local load management PLC modem (ISO 15118) integrated GFCI Type A sufficient for the charging station, GFCI Type B not requiredThe charge controller monitors charging system internal hardware, such as the meter, the user interface board or the socket. It is characterized by its compact design and size that in turn enables intelligent, small and cost effective charging systems. To enable the charge controller to communicate, a backend system is required. Given that most backend providers strictly adhere to the Open Charge Point Protocol (OCPP), the charge controller is OCPP 1.5 and OCPP 1.6 compliant. All specified messages in OCPP are supported as well as some vendor-specific extensions based on the DataTransfer message. Integration tests with the backend implementations of providers such as Vattenfall, Bosch, NTT and DRIIVZ have been successfully carried out. The charge controller can be operated as an “always on” system that is always connected to a mobile network. The controller supports 2.5G Edge and 4G UMTS mobile networks. Connectivity for online operation requires a SIM card (which is not included in delivery). User interaction is facilitated using an RFID module, which consists of an RFID card reader and LEDs. Charging is initiated by holding a valid RFID card close to the reader. In offline operation, the charge controller can optionally allow charging without authorization or it can authorize users based on RFID and a local white list of authorized RFID cards.The software for controlling all processes of the charge controller can be updated. This makes the CC612 future-proof. Updates (typically quarterly) can be easily installed via USB, Ethernet or over-the-air (OTA) Charge controller acc. to IEC 61851-22 (mode 3)It can be configured as either a Master or SlaveThe charge controller can be integrated into a single or three-phase system up to 80 AFuture-proof, encoded and standardised networking with EMS through the EEBUS communication protocolSmart Grid enabled using standard OCPP functionalityOCPP 1.5 and OCPP 1.6 compliant with JSON, SOAP and Binary implementationSupports 4G (LTE), 3G (UMTS) und 2G (GSM) mobile networks with an integrated 4G modem in all data gateways with 4G modemTwo USB interfaces: – CONFIG for local configuration – Other is used an extension port for peripheral USB devices (Ethernet/WiFi home applications) – Master/slave hardware configuartionControl Pilot and Proximity Pilot signal managementUniversal charge plug control (support for different vendors of sockets)Configurable support for one additional household socketCan connect to eHZ or Modbus meters and to meters with an S0 interfaceUser interface board for customer-specific applicationsConfigurable 3-channel input/output extension interface for additional functionalityOnly an external RCD type A is requiredInternal temperature sensorsA Peer Group Mechanism or Dynamic Load Management where a set current is shared between a group of charge controllersOptional integrated ISO/IEC 15118 power line communication (PLC) for plug & charge and load management systemsLocal and remote configuration