Features:
1.Output amplitude (3-digit LED) and output frequency (5-digit LED) can be displayed simultaneously.
2.Can be used as a frequency meter (50MHz and other precision)
3.Multiple output modes: (spot frequency, FM, internal and external frequency sweep)
4.Full-featured output protection
5.High reliability MTBF>10000 hours
6.DC level adjustment function
7.Adopt electronic switch
Technical Date:
Technical Date | |||||
Type | Ⅰ | Ⅱ | |||
Output frequency | 0.1Hz~20MHz | 0.1Hz~3MHz | |||
Output Impedance | Function, Spot Frequency Output 50Ω TTL/CMOS output 600Ω | ||||
Output Signal Waveform |
| ||||
Output signal amplitude | Function Output (1MΩ) No attenuation (1Vp-p~20Vp-p)±10%, continuously adjustable Attenuation 20dB: (0.1Vp-p~2Vp-p)±10%, continuously adjustable Attenuation 40dB: (10mVp-p ~ 200mVp-p) ±10%, continuously adjustable Attenuation 60dB: (1mVp-p~20mVp-p)±10%, continuously adjustable | ||||
TTL output (load resistance ≥600Ω) “0” level: ≤0.8V, “1” level: ≥1.8V | |||||
CMOS output (load resistance ≥2kΩ) “0” level: ≤0.8V, “1” level: 5V~15V continuously adjustable | |||||
Function output signal DC level adjustment range | Off or (-10V~+10V) ±10% (1MΩ load) “Off” position when the output signal carries a DC level of: <0V ±0.1V load resistance of 50Ω, the adjustment range of (-5V~+5V) ± 10% | ||||
Function output signal attenuation | 0dB/20dB/40dB/60dB (0dB attenuation means no attenuation) | ||||
Output Signal Type | Single-frequency signals, swept signals, FM signals (externally controlled) | ||||
Function output asymmetry (SYM) adjustment range | Off or 20%~80% “Off” position when the output waveform is symmetrical waveform, the error ≤ 2% | ||||
Scanning method | Internal scanning method: linear/logarithmic scanning method External Scanning Method: Determined by VCF Input Signal | ||||
Internal Scanning Characteristics | Scanning time: 10ms~5s ±10% Scanning width: ≥1 frequency range | ||||
External Scanning Characteristics | Input impedance: about 500kΩ Input signal amplitude: 0V~+3V Input signal period: 10ms~5s | ||||
Output Signal Characteristics
| Sine wave distortion: < 1% | ||||
Triangular wave linearity: >99% (10% to 90% region of output amplitude) | |||||
Pulse wave up (down) rise time: ≤20ns (10% to 90% of output amplitude) | Pulse wave up (down) rise time: ≤30ns (10% to 90% of output amplitude) | ||||
Pulse wave, rising and falling edge overshoot: ≤5% V0 (50Ω load) | |||||
Output signal frequency stability | ±0.1%/min | ||||
Amplitude display | Display digits: three (automatic positioning of the decimal point) | ||||
Display unit: Vp-p or mVp-p | |||||
Display error (f ≤ 15MHz) V0 ± 20% ± 1 word (peak-to-peak amplitude value of V0 output signal), (V0 reading should be multiplied by 1/2 when load resistance is 50Ω) | |||||
Resolution: 0.1Vp-p (attenuation 0dB), 10mVp-p (attenuation 20dB),1mVp-p (attenuation 40dB),0.1mVp-p (attenuation 60dB) | |||||
Frequency display | Display range: 0.1Hz~20000kHz | ||||
Effective number of display digits: five digits (four digits below 1k grade) | |||||
Point frequency output | Frequency: 100Hz±2Hz; Waveform: Sine; Amplitude: 2Vp-p | ||||
Single pulse output (TTL level) | “0” level ≤ 0.8V; ‘1’ level ≥ 1.8V (load resistance ≥ 600Ω) indicator light for the ‘1’ level, the light is off for the “0” level. | ||||
Power output | | Maximum output power: 5W Output waveform: sine wave Load resistance: ≥8Ω Output frequency range: 0.1Hz~50kHz, f≥50kHz automatic shutdown | |||
Frequency measurement range | 0.1Hz~50MHz | ||||
Input Voltage Range (0dB attenuation) | 150mV~2V (0.1Hz~1Hz) 30mV~2V (1Hz~50MHz) | ||||
Input Impedance | 500kΩ/30pF | ||||
Waveform Adaptation | Sine wave, square wave | ||||
Filter Cutoff Frequency | Approx. 100 kHz (in-band attenuation, meets minimum input voltage requirements) | ||||
Measuring time | 0.3s (fi>3Hz) Single measured signal period (fi≤3Hz) | ||||
Display Mode | Display range: 0.100Hz~50000kHz Display effective number of digits: five | ||||
Measurement error | Time base error ± Trigger error (Trigger error: If the signal-to-noise ratio of the measured signal is better than 40dB during single-cycle measurement, the trigger error is ≤0.3%) | ||||
Time base | Nominal frequency: 10MHz Frequency stability: ± 5 × 10-5/d | ||||
Overall dimensions | 260mm × 90mm × 300mm | ||||
Weights | 3kg | ||||