Technical Data | |
Base condition | 23°C±5°C, below 75%rh |
Measured voltage (V) | 0~2000V Accuracy±2%rdg±3dgt |
Measured leakage current (uA) | 0.1uA~199.9uA Accuracy±3%rdg±5dgt |
DC Voltage Resolution | 1V |
Leakage Current Resolution | 0.1uA |
Insulation resistance | 0~1000MΩ |
Test stabilisation time | ≤3s |
Discharge Tube Voltage Rise Rate | (100±8) V/s |
Power supply | 7.2V high capacity rechargeable battery |
Backlight | Have |
USB data transfer | Have |
Display mode | 5 inch colour screen TFT LCD |
LCD display size | 108mm×65mm |
Instrument size | 240 mm (L) x 188 mm (W) x 85 mm (H) |
Test line | Test lead red 1 metre, black 1 metre |
Data storage | 500 groups |
Data access | Data access function: ‘MR’ symbol display |
Overflow display | Overflow function: ‘OL’ symbol display |
Judgement function | Measured value exceeds the set range |
Working temperature and humidity | -10℃~40℃;below 80%rh |
Storage temperature and humidity | -20℃~60℃;below 70%rh |
Insulation resistance | More than 200MΩ(between the circuit and the housing 500V) |
Pressure resistance | AC 3000V/rms(between the circuit and the housing) |
Electromagnetic properties | IEC61326(EMC) |
Suitable for safety regulations | IEC61010-1(CAT Ⅲ 300V、CAT IV 150V、pollution level 2); |
Power consumption | Standby: about 140mA(Lowest brightness) |
Maximum brightness:about 300mA | |
Measure:about 830mA(Lowest brightness) | |