PinZhi AC/DC Current Probe PT-2710 (60 A p-p, 200 kHz) Oscilloscope Current Clamp

Conversion Ratio: 20X: 50 mV/A; 200X: 5 mV/A

Current Range: 20X: 0.4 A to 10 A p-p; 200X: 10 A to 60 A p-p

DC Current: 30 A

RMS: 21 A rms

Accuracy: 2% ± 5 mV

Bandwidth (-3 dB): DC–200 kHz

Load Impedance: ≥1 MΩ and ≤100 pF

Insertion Impedance: 0.01 Ω

Noise: 2 mV

Rise/Fall Time: 1.75 μs

Operating Voltage: 600 V rms

Common-Mode Voltage: 600 V rms

Battery: 9V alkaline battery (compliant with NEDA 1604A, IEC 6LR61)/144 hours standby

Low battery indicator: LED is green when >6.5V; a flashing green light indicates the battery needs to be replaced

Overload indicator: A red LED indicates the measured current is too high; the range must be changed

Operating temperature: 0–50°C

Operating Humidity: 20–75% RH

Jaw Opening: 11 mm diameter

Output: 2-meter coaxial cable with an insulated BNC connector at the end

Weight: 330 g (including battery)

Dimensions: 231 × 67 × 36 mm