PinZhi AC/DC Current Probe PT-2710 (60 A p-p, 200 kHz) Oscilloscope Current Clamp
Conversion Ratio: 20X: 50 mV/A; 200X: 5 mV/A
Current Range: 20X: 0.4 A to 10 A p-p; 200X: 10 A to 60 A p-p
DC Current: 30 A
RMS: 21 A rms
Accuracy: 2% ± 5 mV
Bandwidth (-3 dB): DC–200 kHz
Load Impedance: ≥1 MΩ and ≤100 pF
Insertion Impedance: 0.01 Ω
Noise: 2 mV
Rise/Fall Time: 1.75 μs
Operating Voltage: 600 V rms
Common-Mode Voltage: 600 V rms
Battery: 9V alkaline battery (compliant with NEDA 1604A, IEC 6LR61)/144 hours standby
Low battery indicator: LED is green when >6.5V; a flashing green light indicates the battery needs to be replaced
Overload indicator: A red LED indicates the measured current is too high; the range must be changed
Operating temperature: 0–50°C
Operating Humidity: 20–75% RH
Jaw Opening: 11 mm diameter
Output: 2-meter coaxial cable with an insulated BNC connector at the end
Weight: 330 g (including battery)
Dimensions: 231 × 67 × 36 mm