rotor Shanghai Pingxuan pointer digital viscometer 1234 rotor 304 corrosion-resistant viscometer accessory
Production of various types of rotary viscometers, can also provide customers with various types of viscometer rotors,
The models of the viscometer include:
NDJ-1
NDJ-4
NDJ-5S
NDJ-8S
NDJ-9S
SNB-1
DV-1 and other models
Product Introduction:
The workmanship is exquisite. All viscometers in our company are equipped with rotor numbers 1-4 as standard when leaving the factory. Choosing rotor numbers 1-4 can make the fixture and the measured object correspond one-to-one, saving cleaning and maintenance when converting between different measured objects and reducing the possibility of cross contamination
No.1-No.4 rotors are accessories for measuring different viscosities with different rotational speeds of viscometers. This series of rotors are made of high-grade materials and exquisite workmanship. All viscometers in our company are equipped with No.1-No.4 rotors as standard. Matching No.1-No.4 rotors can make fixtures and measured objects correspond to each other one by one, eliminating the need for cleaning and maintenance during conversion between different measured objects and reducing the possibility of cross-contamination.
No.1-No.4 rotors are accessories for measuring different viscosities with different rotational speeds of viscometers. This series of rotors are made of high-grade materials and exquisite workmanship. All viscometers in our company are equipped with No.1-No.4 rotors as standard. Matching No.1-No.4 rotors can make fixtures and measured objects correspond to each other one by one, eliminating the need for cleaning and maintenance during conversion between different measured objects and reducing the possibility of cross-contamination.
0# rotor
Features:
1: Specially used for measuring samples with very low viscosity
2: the sample size is only 25ml.
3. Cylindrical rotor can accurately calculate the shear rate, which is convenient for detailed analysis of products.
No.0 rotor viscosity adapterIllustrate:
0# rotor
The low viscosity adapter is an optional accessory and can be used as follows:
1Below15mpa.sSelection of liquid0No. rotor, used0The number rotor does not require a protective frameand will be0Install the rotor on the connecting screw (rotate counterclockwise to install)
2, put the fixing sleeve into the lower cylinder of the instrument, and tighten it with the sleeve fixing screw.
3Pour the outer test tube (with a bottom) intothe inner test tube20-25Milliliters of the tested liquid
4Insert the external test cylinder into the fixedsleeve and tighten it with the test cylinder fixing screw. When tightening, pay attention to the cone end of the test cylinder fixing screw to screw it into the triangular groove on the upper end of the external test cylinder (you can observe whether the triangular groove of the test cylinder is located in the center of the circular hole on the side). After controlling the temperature of the measured liquid, the test can be carried out
5. When the bottomless outer test tube is used, the method is basically the same as above (except for 3). When the outer test tube and the rotor are immersed in the groove ring of the outer test tube, it is taken as the liquid level line.