How to User It?
1.Switch Displayed Parameters:
In
the normal interface, short press SW to switch the displayed content in
the lower line. Current A, power W, capacity Ah, and time h can be
switched. Long press to change the top displayed content, switching
between input voltage IN and output voltage OUT.
2.Set Output Voltage Value:
In
the normal interface, short press U / I button to enter into voltage CC
setting interface. A certain digit of set output voltage is blinking.
Rotate the encoder knob to increase or decrease output voltage. Short
press the knob to select which digit of the output voltage to set. When
the setting is completed, short press U / I button twice to return to
the normal interface. Or it will automatically return to the normal
interface, without operation in 10s.
3. Set Constant Current Value (That is, the maximum output current allowed by the module):
In
the normal interface, short press U / I button to enter voltage
constant current setting interface. Short press U / I button again to
switch to set constant current value. It can be seen that a certain bit
of the constant current value is blinking. Turn the encoder knob to
increase or decrease the value. Short press the encoder to select which
digit of the constant current value to set. When the setting is
completed, short press U / I button to exit the setting interface and
return to the normal interface. Or it will automatically return to the
normal interface, without operation in 10s.
4. Set the Module to be ON/OFF by Default:
In
the normal interface, press and hold U / I button to enter parameter
setting interface. It displays OPEN OFF or OPEN ON. OPEN OFF means the
output is turned off by default when power-on, and OPEN ON means the
output is turned on by default when power-on. Press and hold the rotary
encoder to switch between these two states. After the setting is
completed, press and hold the U / I button to return to the normal
interface.
5. Set Protection Parameters ON and Threshold:
In
the normal interface, press and hold U / I button to enter parameter
setting interface. Short press SW button until the protection parameter
you want to set appears.
LUP: Under-voltage protection threshold
OUP: Over-voltage protection threshold
OCP: Over-current protection threshold
OPP: Over-power protection threshold
OAP: Over-capacity protection threshold
OHP: Timeout protection threshold
OTP: Over-temperature protection threshold
Short
press the rotary encoder to select which digit of the protection
parameter you want to set. Long press the encoder to set protection
parameters ON or OFF (Note: Only timeout protection and over-capacity
protection can be set on / off, other protection parameters are turned
on by default.). Rotate the encoder to change the parameters. After the
setting is completed, press and hold U / I button to return to the
normal interface.
6. Voltage & Current Calibration:
In
the normal interface, press and hold U / I button to enter parameter
setting interface. Short press SW button until the parameter interface
with CAL appears.
Interface with CAL + IN + V is the input voltage calibration interface
Interface with CAL + OUT + V is the output voltage calibration interface
Interface with CAL + OUT + A is the output current calibration interface
Rotate
the encoder left and right to adjust parameters. Press and hold the
encoder to confirm that the adjustment is complete. At this time, the
parameter value does not flash. Long press the U / I button to return to
the normal interface.
Attention:
To ensure the accuracy of calibration, only when the voltage is over
12V can voltage be calibrated. And only when the current is over 1A can
current be calibrated.
Note:
-
The input terminal IN- of the module must not be short-circuited with
the output terminal OUT-, otherwise the constant current function will
fail.
- Please ensure that the power of your power supply is greater than the power required by the output load.
-
When users need the module to output at full load, input voltage needs
to be larger than 8V. When input voltage is 5V, output power is about
15W. The maximum current of module is 4A, which is limited by the
maximum output power. For example, if the output is 17V, current should
not be greater than 2A.
- When this module is used over 3A, 35W, please strengthen heat dissipation devices.
-
The module has input under-voltage protection function. The default
value is about 4.8V (can be set). If it is lower than this value, output
will be automatically disconnected (Attention: The voltage at the port
of module is lower than the under-voltage protection threshold. When
input current is relatively large, please not ignore the divided voltage
on input wire).