NEW, MADE IN GERMANY, EATON MOELLER MODEL NHI-E-11-PKZ0, XTPAXFA11 FRONT MOUNT AUXILIARY CONTACT. 1 NORMALLY OPEN, 1 NORMALLY CLOSED.
| Moeller Part No. | NHI-E-11-PKZ0 |
| Eaton Part No. | XTPAXFA11 |
| Delivery program | |
|---|---|
| Product range | Standard auxiliary contact |
| For use with | PKZ0(4) standard auxiliary contacts |
| Contacts | |
| N/O = Normally open | 1 N.O. |
| N/C = Normally closed | 1 N.C. |
| Connection technique | Screw terminals |
| For use with | PKZM01 PKZM0 PKZM4 PKZM0-T PKM0 PKE |
| Notes: Can be retrofitted to motor-protective circuit-breakers, transformer-protective circuit-breakers, motor-protective circuit-breakers for starter combinations from serial number 01. 45 mm (PKZM0 and PKZM01) or 55 mm (PKZM4) widths of the motor-protective circuit-breakers remain unchanged. NHI-E...-PKZ0-C not usable for MSC...-type motor starter combinations. | |
| Technical data | |
| Auxiliary contacts | |
| Rated impulse withstand voltage (Uimp) | 4000 |
| Overvoltage category/pollution degree | III/3 |
| Rated operational voltage (Ue) | 440 V AC |
| 250 V DC | |
| Safe isolation to EN 61140 Between auxiliary contacts and main contacts | 690 V AC |
| Rated operational current AC-15 | |
| 220 - 240 V | 1 A |
| Rated operational current DC-13 L/R - 100 ms | |
| 24 V | 2 A |
| Lifespan, mechanical (Operations) | > 0.1 |
| Lifespan, electrical (Operations) | 0.1 |
| Control circuit reliability (Failure rate) | <10-8, one failure at 100 million operations (at Ue = 24 V DC, Umin = 17 V, Imin = 5.4 mA) |
| interlocked opposing contacts | yes |
| Short-circuit rating without welding | |
| Fuse (A gG/gL) | 10 |
| Terminal capacities | |
| Solid or flexible conductor, with ferrule | 0,75 - 2,5 |
| Solid or stranded | 18 - 16 |
| Design verification as per IEC/EN 61439 | |
| Technical data for design verification | |
| Rated operational current for specified heat dissipation | 1 A |
| Heat dissipation per pole, current-dependent | 0.01 W |
| Heat dissipation capacity | 0 W |
| IEC/EN 61439 design verification | |
| 10.2 Strength of materials and parts | |
| 10.2.2 Corrosion resistance | Meets the product standard's requirements. |
| 10.2.3.1 Verification of thermal stability of enclosures | Meets the product standard's requirements. |
| 10.2.3.2 Verification of resistance of insulating materials to normal heat | Meets the product standard's requirements. |
| 10.2.3.3 Verification of resistance of insulating materials to abnormal heat and fire due to internal electric effects | Meets the product standard's requirements. |
| 10.2.4 Resistance to ultra-violet (UV) radiation | Meets the product standard's requirements. |
| 10.2.5 Lifting | Does not apply, since the entire switchgear needs to be evaluated. |
| 10.2.6 Mechanical impact | Does not apply, since the entire switchgear needs to be evaluated. |
| 10.2.7 Inscriptions | Meets the product standard's requirements. |
| 10.3 Degree of protection of ASSEMBLIES | Does not apply, since the entire switchgear needs to be evaluated. |
| 10.4 Clearances and creepage distances | Meets the product standard's requirements. |
| 10.5 Protection against electric shock | Does not apply, since the entire switchgear needs to be evaluated. |
| 10.6 Incorporation of switching devices and components | Does not apply, since the entire switchgear needs to be evaluated. |
| 10.7 Internal electrical circuits and connections | Is the panel builder's responsibility. |
| 10.8 Connections for external conductors | Is the panel builder's responsibility. |
| 10.9 Insulation properties | |
| 10.9.2 Power-frequency electric strength | Is the panel builder's responsibility. |
| 10.9.3 Impulse withstand voltage | Is the panel builder's responsibility. |
| 10.9.4 Testing of enclosures made of insulating material | Is the panel builder's responsibility. |
| 10.10 Temperature rise | The panel builder is responsible for the temperature rise calculation. Eaton will provide heat dissipation data for the devices. |
| 10.11 Short-circuit rating | Is the panel builder's responsibility. The specifications for the switchgear must be observed. |
| 10.12 Electromagnetic compatibility | Is the panel builder's responsibility. The specifications for the switchgear must be observed. |
| 10.13 Mechanical function | The device meets the requirements, provided the information in the instruction leaflet (IL) is observed. |
| Technical data ETIM 5.0 | |
| Low-voltage industrial components (EG000017) / Auxiliary contact block (EC000041) | |
| Electric engineering, automation, process control engineering / Low-voltage switch technology / Component for low-voltage switching technology / Auxiliary switch block (ecl@ss8-27-37-13-02 [AKN342009]) | |
| Number of contacts as change-over contact | 0 |
| Number of contacts as normally open contact | 1 |
| Number of contacts as normally closed contact | 1 |
| Rated operation current Ie at AC-15, 230 V | 1 A |
| Type of electric connection | Screw connection |
| Mounting method | Front Fastening |
| Approvals | |
| Product Standards | UL 508; CSA-C22.2 No. 14; IEC60947-4-1; CE marking |
| UL File No. | E36332 |
| UL Category Control No. | NLRV |
| CSA File No. | 165628 |
| CSA Class No. | 3211-05 |
| North America Certification | UL listed, CSA certified |
PLEASE VIEW THE PICTURES AND CONTACT ME WITH ANY QUESTIONS
FREE SHIPPING! (FREE SHIPPING APPLIES TO UNITED STATES ADDRESS ONLY) EVERYTHING THAT WE SELL IS ON-HAND AND IN STOCK, SHIPPED FROM CENTRAL USA. MOST ITEMS SHIP WITHIN ONE BUSINESS DAY. WE SHIP EVERY DAY MONDAY THROUGH FRIDAY UNLESS THERE ARE SPECIAL CIRCUMSTANCES. WE PROMISE AN HONEST, FAST AND COURTEOUS TRANSACTION! THANK YOU VERY MUCH AND HAVE A WONDERFUL DAY! JOE&BRIDGET.... please check out our other listings.