703 Autostart Control Module Generator Set Controller
Description:
- Type:703
- Apply:Suits for most of generator
- DC Supply: 8 Volts to 35 Volts DC Continuous
- Cranking Dropouts: Able to survive 0 Volts for 50 mS, providing supply was at
- least 10 V before dropout and supply recovers to 5 Volts.(This is achieved without the need for internal batteries.)
- Max. current: Operating 50mA
- Standby current:10mA
- Alternator Input Range: 75 Volts (ph-N) to 277 Volts (ph-N) AC (+20%)
- Alternator Input Frequency: 50 - 60 Hz at rated engine speed
- (Minimum: 75V AC Ph-N)
- (Crank Disconnect from 15V Ph-N @ 20Hz)
- Overspeed +14% (+24% overshoot)
- Underspeed –20%
- Start Output: 1.2 Amp DC at supply voltage
- Fuel Output: 1.2 Amp DC at supply voltage
- Auxiliary Outputs: 1.2 Amp DC at supply voltage
- Dimensions: 125mm x 165mm x 28 mm
- Charge Fail: 12 Volts = 8 Volts CF 24 Volts = 16 Volts CF
- Operating Temperature Range: -30℃ ~ + 70℃
Package include:
- 1 x 703 Autostart Control Module
- 1 x User Manual