SICK DT35-B15551 Mid Range Distance Sensors, New
|
Measuring range |
50 mm ... 12,000 mm, 90 % remission 1) 2) 50 mm ... 5,300 mm, 18 % remission 50 mm ... 3,100 mm, 6 % remission |
|
Target |
Natural objects |
|
Resolution |
0.1 mm |
|
Repeatability |
≥ 0.5 mm 2) 3) 4) |
|
Accuracy |
Typ. ± 10 mm 4) |
|
Response time |
4.5 ms ... 192.5 ms, 4.5 ms / 12.5 ms / 24.5 ms / 48.5 ms / 192.5 ms 5) 6) |
|
Switching frequency |
166 Hz/50 Hz/25 Hz/12 Hz/3 Hz 5) 6) |
|
Output time |
2 ms ... 64 ms, 2 ms/4 ms/8 ms/16 ms/64 ms 5) 7) |
|
Light source |
Laser, red 8) |
|
Laser class |
1 (IEC 60825-1:2014, EN 60825-1:2014) |
|
Typ. light spot size (distance) |
15 mm x 15 mm (at 2 m) |
|
Additional function |
Set speed: Super Fast ... Super Slow, teach-in of analog output and invertible analog output, Output Q2,selectable: 4 mA ... 20 mA / 0 V ... 10 V / switching output, Switching mode: Distance to Object (DtO) / switching window / object between sensor and background (ObSB), teach-in of switching output and switching output invertible, Multifunctional input: laser off / external teach / deactivated, reset to factory default |
|
Supply voltage Vs |
DC 12 V ... 30 V 1) 2) |
|
Ripple |
≤ 5 Vpp 3) |
|
Power consumption |
≤ 1.7 W 4) 5) |
|
Initialization time |
≤ 500 ms |
|
Warm-up time |
≤ 20 min |
|
Housing material |
Plastic (ABS and PC) Acrylic glass (PMMA) |
|
Connection type |
Male connector, M12, 5-pin |
|
Indication |
LEDs |
|
Weight |
65 g |
|
Enclosure rating |
IP65 IP67 |
|
Protection class |
III |