VICTOR 4091B LCR Meter Digital Bridge Capacitance Inductance Test Instrument
Notice:
The standard package don't include batteries.
Because,the international air shipping forbid to ship liquid,powder and batteries,
we can not put them in the package box.
Hope you can understand buy them in your local store or supermarket.
At the same time, please forgive us that we are unable to provide the English user manual.
If you need it, please contact the customer service after purchase.
Thanks for your support!
Features
The measurement frequency is up to 100kHz, and the step is continuously adjustable at 1Hz
Test level 10~2000mV, 1mV step continuously adjustable
Support DC resistance (DCR), electrolytic capacitor measurement Internal bias voltage output 10mV~1500mV
3.5-inch TFT display, 5-digit display Communication: USB Device, RS232 (or 485), Handle, GPIB (optional), USB Host (optional)
Data recording function (maximum, minimum, average)
Support SCPI communication protocol
Provide system settings, Chinese or English, buzzer, screen brightness, etc. can be configured according to needs
Basic measurement accuracy 0.2%
Manual and automatic range
With open circuit and short circuit calibration function
Comparator sorting (5 gears), alarm function
|
model |
VICTOR 4090A |
VICTOR 4090B |
VICTOR 4090C |
VICTOR 4091A |
VICTOR 4091C |
|
Test frequency |
10 Points (100,120,200,400, 800,1K,2K,4K,8K,10K) |
12 Points (100,120,200,400,800, 1K,2K,4K,8K,10K,15K,20K)
|
16 Points (100,120,200,400,800,1K,2K ,4K,8K,10K,15K,20K,40K,50K,80K,100K) |
10~10KHz is continuously adjustable, 1Hz step |
10~100KHz Continuous Adjustable, 1Hz Steps |
|
Display screen |
3.5 inch TFT LCD display |
||||
|
Display digits |
Main parameter: 5 digits, secondary parameter: 5 digits |
||||
|
Measurement parameters |
Main parameter: L/C/R/Z, secondary parameter: X/D/Q/θ/ESR |
||||
|
Measuring range (L) |
0.01μH-9999H |
||||
|
Measuring range (C) |
0.01pF-99.999mF |
||||
|
Measuring range (R) |
0.0001Ω-99.999MΩ |
||||
|
Basic accuracy |
0.2% |
||||
|
Measuring speed |
2 times/second (slow speed), 4 times/second (medium speed), 8 times/second (fast speed) |
||||
|
Internal bias |
0-1500mV adjustable, 1mV step. |
||||
|
Test level |
6 fixed level points (0.1V,0.3V,0.6V,1V,1.5V, 2V) |
0.1V~2V level is continuously adjustable, with 1mV step. |
|||
|
Signal source output impedance |
30Ω、100Ω |
||||
|
Calibration function |
Open circuit calibration, short circuit calibration |
||||
|
Filter function |
The screening limit range can be set from -50% to +50%, among which the fixed points are 1%, 5%, 10%, 20% |
||||
|
Comparator sorting |
Five grades sorting, three grades are qualified, one grade is unqualified, and one subsidiary grade |
||||
|
Communication Interface |
Standard RS232 (or 485), USB Device, Handle, optional GPIB, USB Host |
||||
|
other |
Support DC resistance (DCR), electrolytic capacitor measurement mode, adjustable backlight brightness, Chinese and English optional |
||||
Main technical indicators
General technical specifications
Power supply voltage: 220V.AC±10%, 110V.AC±10% (optional), 45~65Hz
Power consumption: <20W
Display: 3.5-inch TFT LCD screen, resolution 480×320, color 16M
Temperature range: operating state 10℃~+40℃, non-operating state -10℃~+60℃
Humidity range: within the range of 0~40℃, ≤90% relative humidity
Interface: standard RS232 (or 485), USB Device, Handle, optional GPIB, USB Host