PRODUCT DESCRIPTION

This product has been discontinued by the manufacturer.

The Fire-Lite MS-10UD-7 is a ten-zone conventional fire alarm control panel with ten Class B initiating zones, four Class B NACs, and a built-in DACT for central station communication. It includes the cabinet and FLPS-7 power supply, provides 7.0 A of total system current, and supports up to eight ANN-BUS devices.

Model Variants:
MS-10UD-7 - New ten-zone, 120 VAC panel with cabinet and 7.0 A total system current
MS-10UD-7 Replacement Board (Refurbished) - Refurbished main control board only
MS-5UD-3 - New five-zone, 120 VAC panel with 3.0 A total system current
MS-5UD-3 (Refurbished) - Refurbished five-zone, 120 VAC panel

Key Specifications:
Type: Ten-zone conventional FACP with built-in DACT
Zone Capacity: Ten Style B (Class B) initiating device circuits
NAC Circuits: Four Style Y (Class B) NACs; 3.0 A maximum per circuit within the panel's 7.0 A total capacity
Power: 120 VAC, 50/60 Hz, 3.8 A input; 24 VDC system operation
System Output: 7.0 A total system current
Auxiliary Power: 24 VDC resettable or nonresettable output; 500 mA maximum
Battery Support: 7 to 26 AH sealed lead-acid batteries; batteries above 18 AH require a separate battery cabinet
Relays: Three programmable Form C relays for alarm, trouble, and supervisory
Dialer/Communicator: Built-in DACT for central station reporting and local or remote upload/download
Annunciator Capacity: Up to eight ANN-BUS devices
Indicators/UI: 80-character backlit LCD, keypad, status LEDs, and onboard piezo sounder

Compatible Modules & Accessories:
FLPS-7 - Internal power supply
ANN-80 - Red 80-character LCD annunciator
ANN-80-W - White 80-character LCD annunciator
ANN-RLY - 10-relay ANN-BUS module
CAC-5X - Class A converter module; two required to convert all panel circuits
4XTMF - Municipal box and reverse-polarity transmitter module

Compatible Detectors & Devices:
System Sensor 2W-B - Two-wire i3 photoelectric smoke detector
System Sensor 2WT-B - Two-wire i3 smoke and heat detector
System Sensor 4W-B - Four-wire i3 photoelectric smoke detector
Fire-Lite BG-12L - Conventional dual-action pull station

System Compatibility: System Sensor i3 series detectors and listed conventional two-wire and four-wire smoke detectors, heat detectors, pull stations, waterflow devices, tamper switches, and normally open contact devices.
This product has been discontinued by the manufacturer.The Fire-Lite MS-10UD-7 is a ten-zone conventional fire alarm control panel with ten Class B initiating zones, four Class B NACs, and a built-in DACT for central station communication. It includes the cabinet and FLPS-7 power supply, provides 7.0 A of total system current, and supports up to eight ANN-BUS devices.Model Variants:MS-10UD-7 - New ten-zone, 120 VAC panel with cabinet and 7.0 A total system currentMS-10UD-7 Replacement Board (Refurbished) - Refurbished main control board onlyMS-5UD-3 - New five-zone, 120 VAC panel with 3.0 A total system currentMS-5UD-3 (Refurbished) - Refurbished five-zone, 120 VAC panelKey Specifications:Type: Ten-zone conventional FACP with built-in DACTZone Capacity: Ten Style B (Class B) initiating device circuitsNAC Circuits: Four Style Y (Class B) NACs; 3.0 A maximum per circuit within the panel's 7.0 A total capacityPower: 120 VAC, 50/60 Hz, 3.8 A input; 24 VDC system operationSystem Output: 7.0 A total system currentAuxiliary Power: 24 VDC resettable or nonresettable output; 500 mA maximumBattery Support: 7 to 26 AH sealed lead-acid batteries; batteries above 18 AH require a separate battery cabinetRelays: Three programmable Form C relays for alarm, trouble, and supervisoryDialer/Communicator: Built-in DACT for central station reporting and local or remote upload/downloadAnnunciator Capacity: Up to eight ANN-BUS devicesIndicators/UI: 80-character backlit LCD, keypad, status LEDs, and onboard piezo sounderCompatible Modules & Accessories:FLPS-7 - Internal power supplyANN-80 - Red 80-character LCD annunciatorANN-80-W - White 80-character LCD annunciatorANN-RLY - 10-relay ANN-BUS moduleCAC-5X - Class A converter module; two required to convert all panel circuits4XTMF - Municipal box and reverse-polarity transmitter moduleCompatible Detectors & Devices:System Sensor 2W-B - Two-wire i3 photoelectric smoke detectorSystem Sensor 2WT-B - Two-wire i3 smoke and heat detectorSystem Sensor 4W-B - Four-wire i3 photoelectric smoke detectorFire-Lite BG-12L - Conventional dual-action pull stationSystem Compatibility: System Sensor i3 series detectors and listed conventional two-wire and four-wire smoke detectors, heat detectors, pull stations, waterflow devices, tamper switches, and normally open contact devices.

WHAT OUR CUSTOMERS ARE SAYING

Order delivered on time with no issues gegl42 (58 )
Order delivered on time with no issues aadandr_b33pzp (77 )
Order delivered on time with no issues dealsoftheday9068 (330 )
Thanks for shopping with Cargo Largo where you can discover shop and WIN! cargolargo (679962 )
Order delivered on time with no issues kcopenhaver80 (55 )