WEN Magnetic Base Mount 10711 — Dial Indicator Holder, Magnetic Base, Fine Adjust, Support Rod

Brand: WEN
Model: 10711
MPN: 10711
UPC: 044459107118
Type: Magnetic Base Mount / Dial Indicator Holder
Power Source: Magnetic (manual ON/OFF)
Features: Fine adjustment, Support rod, Lug, Clamp knob
Material: Metal
Country/Region of Manufacture: (fill from unit label)
Modified Item: No/Yes (as applicable)
Custom Bundle: List included items (lug, nut, washer, support rod, etc.)


WEN Magnetic Base Mount (Model 10711) Instruction Manual

INSTRUCTION MANUAL

CARE & SAFETY
CAUTION: Follow the safety precautions below to reduce the risk of damaging your instrument.

Do not bring the magnetic base near data storage media (hard drives, USB drives etc.) due to the magnetic force it can destroy stored data.
Make sure the magnetic base is on a firm, clean surface (no oil, grease, paint, burrs, or other material). Surface roughness, paint, or other contamination may reduce magnetic holding strength.
Make sure the magnetic base is fully ON (magnet engaged) when in use to prevent the device from slipping.
Keep the magnetic base switched to the OFF position when not in use.
Keep the magnet away from pacemakers, medical devices or transformers or demagnetizers.
Do not disassemble the magnetic base. Use of nonapproved parts or disassembly may affect the performance of the device.
To prevent damage to the magnetic base, avoid hitting or dropping it.
OPERATION
1A. FIX A MEASURING TOOL BY THE LUG (FIG. 2)

Remove the nut and washer from the lug fixture.
Insert the measuring tool into the lug fixture (Fig. 3).
Insert the bolt through the measuring tool, lug fixture and nut (Fig. 3).
Tighten the nut until the measuring device is secure.
1B. FIX A MEASURING TOOL IN THE DIAL INDICATOR MOUNTING HOLE (FIG. 4)

Remove the nut and washer from the lug fixture.
Insert the lug fixture into the dial indicator mounting hole.
Insert the bolt through the measuring tool, lug fixture and nut.
Tighten the nut until the measuring device is secure.
Mount the device on a metal surface where the magnetic base can secure firmly.
Make sure the magnetic base is in the ON position when in use.
Slightly loosen the clamp knob. Adjust the inclination and position of the support rod and measuring device.
Tighten the clamp knob to secure the tool.
The fine adjustment knob is used to precisely change the measuring device orientation and zero point.
NOTE: If fixing a measuring device with a stem less than 10 mm in length, it is recommended that you fix the tool
by the lug rather than using the dial indicator mounting hole.
FIG. 2 (illustration showing lug, nut, washer, mounting hole, support rod, clamp knob, dial indicator mounting hole)
FIG. 3 (illustration showing lug, thread, washer, nut)
FIG. 4 (illustration showing dial indicator and mounting arrangement)

TROUBLESHOOTING GUIDE
PROBLEM — POSSIBLE CAUSE — SOLUTION
Base will not magnetize:

Measuring device improperly fastened. — 1. Refer to the OPERATION section for proper installation and reattach device securely.
Surface is not suitable. — 2. Clean surface; remove coatings or oil. Use on proper use or storage. Incorrect measurement:
Measuring device improperly fastened. — 1. Refer to the OPERATION section for proper installation and reattach device securely.
Magnet is permanently damaged. — 2. Replace the magnetic base.
NEED HELP? CONTACT US!
To purchase accessories and replacement parts for your tool, visit WENPRODUCTS.COM
1-inch Dial Indicator (Model 10702, 10703)
Have product questions? Need technical support? Please feel free to contact us:
1-800-232-1195 (M-F, 8AM-5PM CST)
TECHSUPPORT@WENPRODUCTS.COM

CARE & SAFETY (repeated narrow column text)

Do not bring the magnetic base near data storage media (hard drives, USB drives etc.) due to the magnetic force it can destroy stored data.
Keep the device away from pacemakers, medical devices or transformers or demagnetizers.
Make sure the magnetic base is fully ON (magnet engaged) when in use to prevent the device from slipping.
Keep the magnetic base switched to the OFF position when not in use.
Keep the magnet away from pacemakers, medical devices or transformers or demagnetizers.
Do not disassemble the magnetic base.
To prevent damage to the magnetic base, avoid hitting or dropping it.