HYDAC VD 5D.0/-L110 Differential Pressure Clogging Indicator, 6000 psi

See pictures--it's not in the plastic or bag anymore. I put it in a clean plastic bag.

Specific model of a visual and electrical differential pressure clogging indicator (a "dirt alarm") used in hydraulic systems.
  • Function: This device is a differential pressure clogging indicator used to alert an operator (both visually and electrically) when a hydraulic filter element is near capacity and requires changing. It measures the pressure drop across the filter element.
  • Response Pressure: The indicator is set to trip at a differential pressure of 5 bar (approximately 72 psi).
  • Maximum Operating Pressure: It can withstand a maximum system operating pressure of 420 bar (approximately 6000 psi).
  • Voltage: The electrical switch operates on 110–115V AC/DC.
  • Connection Size: It uses a G 1/2 connection size.
  • Sealing Material: The standard sealing material is NBR (Perbunan).
  • Maximum Operating Temperature: The device has a maximum operating temperature of 100 °C (212 °F)

Shipping is $4.95

NO Returns ..  Unless Defective

Please email me with any questions

After you leave me feedback, I will leave you yours.. Thank you

Rack 10
Tier 2
O