| Manufacturer | Siemens |
|---|---|
| MPN | 6ES5310-3AB11 |
| Model / platform | IM 310 / SIMATIC S5 |
| Function | Expansion-unit interface module |
| GTIN / EAN | 4025515115311 |
| Installation | Compact version for distributed expansion |
| System cable distance | Up to 200 m; configuration dependent |
| Country of origin | Germany |
| Stock reference / quantity | B71 / one module per purchase |
Check the part number, specifications, condition and photographs against your requirements before ordering. See the product details below for any specific compatibility notes.
Siemens SIMATIC S5 IM 310 interface module, order number 6ES5310-3AB11, for the expansion-unit end of a distributed S5 installation. Intended for maintaining compatible legacy industrial automation systems.
Siemens documents the IM 301 / IM 310 arrangement with 6ES5 721-series connecting cables over 1–200 m, subject to the rack and interface combination. Supported expansion arrangements include EU 183U and ER 701-2/701-3 with IM 301-3; EU 183U/EU 185U with IM 301-5. The final IM 310 in the chain requires the specified 6ES5 760-1AA11 terminator. Check the system manual before ordering.
Installation: disconnect equipment power and use electrostatic-discharge precautions. Installation and configuration should be carried out by qualified personnel. Verify the complete part number, rack, companion interface and cable arrangement. Rack, CPU, cables and termination accessories are not included unless expressly shown and stated.
One new old-stock Siemens IM 310 module in the pictured original packaging. The carton has visible age, marks and storage wear. The photographs show the packaging; no claim of recent functional testing is made. Stock reference B71.
Available services, charges and estimated delivery dates are shown in the Postage, returns and payments section of this listing.
Please refer to the return terms displayed on this listing. For help with an order, contact us through eBay.
Use eBay's Contact seller option and quote the part number or stock reference so we can identify the item.